SearcharxivSearch

arXiv subjects

Maxime Lamotte

Publications and source records attributed to Maxime Lamotte.

4 recordsLinked to original sources

Lifting the degeneracy of quantum spin liquid phase by uniaxial pressure

We report muon spin relaxation/rotation ($\mu$SR) measurements of the candidate three-dimensional (3D) quantum spin liquid (QSL) PbCuTe$_2$O$_6$, hosting $S=1/2$ moments, under controlled in situ [110] uniaxial compression up to $\sigma_{[110]}=37.7$~MPa. A small directional lattice perturbation significantly modifies the local magnetic response, while above $\sigma_{\rm cr}\sim10.8$\,MPa the relaxation rates are strongly enhanced and the internal-field distribution is substantially broadened. These changes occur along with the local crystalline symmetry breaking. While, no evidence for conventional static long-range magnetic order is observed, the compression drives the system towards a structurally modified and strongly correlated state in which enhanced quasi-static correlations coexist with persistent slow spin dynamics. This work demonstrates a clean and symmetry-selective route to control frustrated exchange landscape and access hidden magnetic instabilities in a 3D QSL candidate opening up the possibilities to tune other correlated systems where intrinsic coupling between magnetic and lattice degrees of freedom are relevant.

cond-mat.str-el

Secondary electron yield from aluminium-coated foils for muon tagging and beam monitoring up to 60 MeV/c

The feasibility of foil-based muon tagging is investigated in the momentum range below 60 MeV/c, with particular focus on its applicability to the low-momentum range spanning approximately 2.5 MeV/c to 20 MeV/c, where no efficient and minimally invasive detection scheme is currently established for continuous beams. Secondary electron emission from a 7 um Mylar foil coated with 50 nm aluminium is investigated using a continuous negative muon beam with nominal momenta between 12 MeV/c and 60 MeV/c at the piE1 beamline at PSI. The emitted electrons are detected with position-sensitive microchannel plate detectors, enabling particle tagging and spatial characterization of the beam. The detection efficiency and corresponding secondary electron yield are extracted and benchmarked against literature data for protons, showing good agreement and confirming reliable muon tagging. The observed trend for negative muons is consistent with the well-established increase in ion-induced secondary electron emission toward lower particle velocities, suggesting improved performance in the low-momentum regime. A proof-of-principle reconstruction of the muon beam profile is demonstrated by correlating detected electron positions with their emission point at the foil. These results establish foil-based tagging as a viable approach for combined timing and minimally invasive beam monitoring, bridging the gap between high- and low-energy muon instrumentation.

physics.ins-det

High-Resolution Timing for Vertex-Reconstructed Muon-Spin Spectroscopy Using Plastic Scintillators and MuTRiG

Vertex-reconstructed muon-spin spectroscopy (vx-{\mu}SR) based on silicon pixel detectors has recently demonstrated unprecedented lateral resolution and operation at muon stop rates exceeding 400 kHz. However, the intrinsic timing resolution of current silicon pixel detector technology limits the accessible frequency range and restricts {\mu}SR measurements with fast relaxation rates. In this work, we report on the integration of plastic scintillator detectors (PSD) read out with the MuTRiG ASIC into the MuSiP vx-{\mu}SR spectrometer. This complements the spatial resolution achieved by using silicon pixel detectors with high-precision timing information for incoming muons and decay positrons. We demonstrate stable operation of MuTRiG in vacuum and achieve sub-300 ps time resolution after time-walk correction. Standard transverse-field {\mu}SR measurements on a SiO$_2$ sample confirm that the combined MuTRiG-PSD system resolves precession frequencies beyond 50 MHz, far exceeding the capabilities of silicon pixel detectors alone. These results establish a viable and scalable path towards high-rate, high-resolution {\mu}SR with both excellent spatial and temporal performance.

physics.ins-det

A comparison of simulation tools for Muon-Induced X-ray Emission (MIXE) in thin films: a study case with lithium batteries

We present a comparative study of three Monte Carlo simulation frameworks -SRIM, GEANT4, and PHITS- for modeling the transport, stopping, and atomic cascade of negative muons in micrometer-scale, multilayer systems relevant to Muon-Induced X-ray Emission (MIXE) experiments at the Paul Scherrer Institute (PSI). Using a lithium-ion battery as a benchmark target, simulated implantation profiles are compared with experimental data from the GIANT spectrometer. All three codes reproduce the overall muon depth distributions with good consistency, even across sharp density contrasts. SRIM provides reliable implantation estimates for compact geometries, whereas PHITS reproduces GEANT4 results with comparable accuracy and additionally generates muonic X-ray spectra. These spectra, however, exhibit a systematic energy offset in the K-line transitions of medium- and high-Z elements relative to theoretical and experimental values. Despite this bias, PHITS accurately captures relative intensities and spectral shapes, enabling element-specific line identification. The results demonstrate that SRIM and PHITS constitute practical tools for rapid estimation of muon implantation and stopping profiles, and that PHITS holds strong potential for predictive MIXE spectroscopy once its transition-energy bias is corrected.

hep-ex