SearcharxivSearch

arXiv subjects

Maximilian Gram

Publications and source records attributed to Maximilian Gram.

3 recordsLinked to original sources

OpenMRF: A Modular, Vendor-Neutral Open-Source Framework for Reproducible Magnetic Resonance Fingerprinting using Pulseq

Purpose: Widespread adoption and methodological advancement of Magnetic Resonance Fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open-source tools. To address these barriers, we introduce OpenMRF - a comprehensive Pulseq-based solution - designed to enable consistent, reproducible, and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq-based sequence design, Bloch-simulation-based dictionary creation directly from .seq files, and iterative low-rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi-site ISMRM/NIST phantom study on Siemens MRI systems at 0.55 T, 1.5 T, and 3 T as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST-like digital phantom, with low-rank reconstruction yielding deviations of 0.03+/-0.32 % (T1) and 0.12+/-1.94 % (T2). The multi-site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of -0.1+/-2.9 % (T1), -1.5+/-8.7 % (T2), and -4.0+/-7.2 % (T1rho). In vivo acquisitions produced high-quality parameter maps across platforms and field strengths. Conclusion: OpenMRF provides a robust, open-source, end-to-end Pulseq-based solution for MRF that enables reproducible sequence implementation, physics-accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and multi-site validation, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.

physics.med-ph

Image space formalism of convolutional neural networks for k-space interpolation

Purpose: Noise resilience in image reconstructions by scan-specific robust artificial neural networks for k-space interpolation (RAKI) is linked to nonlinear activations in k-space. To gain a deeper understanding of this relationship, an image space formalism of RAKI is introduced for analyzing noise propagation analytically, identifying and characterizing image reconstruction features and to describe the role of nonlinear activations in a human readable manner. Methods: The image space formalism for RAKI inference is employed by expressing nonlinear activations in k-space as element-wise multiplications with activation masks, which transform into convolutions in image space. Jacobians of the de-aliased, coil-combined image relative to the aliased coil images can be expressed algebraically, and thus, the noise amplification is quantified analytically (g-factor maps). We analyze the role of nonlinearity for noise resilience by controlling the degree of nonlinearity in the reconstruction model via the negative slope parameter in leaky ReLU. Results: The analytical g-factor maps correspond with those obtained from Monte Carlo simulations and from an auto differentiation approach for in vivo brain images. Apparent blurring and contrast loss artifacts are identified as implications of enhanced noise resilience. These residual artifacts can be traded against noise resilience by adjusting the degree of nonlinearity in the model (Tikhonov-like regularization) in case of limited training data. The inspection of image space activations reveals an autocorrelation pattern leading to a potential center artifact. Conclusion: The image space formalism of RAKI provides the means for analytical quantitative noisepropagation analysis and human-readable visualization of the effects of the nonlinear activation functions in k-space.

cs.CV

Rotary Excitation of non-sinusoidal pulsed magnetic fields: Towards non-invasive direct detection of cardiac conduction

Purpose: In the recent past, spin-locking MRI experiments were successfully applied for the direct detection of sinusoidal magnetic field oscillations in the sub-nT range. In the present study, this detection approach was extended to non-sinusoidal pulsed magnetic fields based on the Rotary Excitation (REX) mechanism. Methods: The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin-locked magnetization and low-frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3T. Gaussian and Sinc-shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a Magnetocardiogram, was tested. Results: Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin-lock frequency coincides with a non-zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude (R2>0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS-like fields with varying QRS durations yielded significant results in a phantom setup (p<0.001). Conclusion: REX detection can be transferred to non-sinusoidal pulsed magnetic fields and could provide a non-invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.

physics.med-ph