Searcharxiv⌕ Search

arXiv subjects

Maximilian R. Rokuss

Publications and source records attributed to Maximilian R. Rokuss.

5 recordsLinked to original sources

Rethinking Post-Hoc Calibration in Semantic Segmentation

Reliable confidence estimates are essential in semantic segmentation, yet modern models often remain miscalibrated. We investigate two overlooked issues in post-hoc calibration. First, adding a constant to all logits leaves softmax probabilities unchanged, but several standard calibrators depend on this arbitrary offset. In segmentation, this offset can vary across pixels or voxels, introducing spatially varying representation dependence. We characterize translation-invariant (TI) calibrators and construct TI counterparts of shift-sensitive methods. Second, calibrating with cross-entropy can degrade segmentation quality due to mismatched training and calibration objectives and limited calibration data. We investigate decision-preserving calibration under argmax- and order-preservation constraints. Since these constraints restrict affine softmax calibrators to temperature scaling, we introduce more expressive class-conditional affine calibrators that preserve decisions. Across natural-image and medical segmentation benchmarks, including corruption-based covariate shift, TI variants generally improve calibration, while decision-preserving variants prevent segmentation degradation by construction and retain strong calibration performance. Our findings provide practical design principles for post-hoc calibration in semantic segmentation.

cs.CV↗

The TopCoW Challenge -- Topology-Aware Circle of Willis Segmentation for CT and MR Angiography

The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain. Its vascular architecture is believed to influence the risk, severity, and outcome of serious neurovascular diseases. However, characterizing the highly variable CoW anatomy remains a manual and time-consuming expert task. The CoW is commonly imaged by two non-invasive angiographic imaging modalities, magnetic resonance angiography (MRA) and computed tomography angiography (CTA), yet few datasets with annotated CoW anatomy exist, and there have been no established benchmarks for comparing CoW segmentation algorithms. We organized the TopCoW benchmark challenge alongside the release of an annotated CoW dataset with 125 paired MRA and CTA scans from the same patients. Voxel-level annotations for 13 vessel components were created using virtual reality technology and verified by clinical experts. Participants submitted algorithms for CoW segmentation and variant classification, which we evaluated on internal and external test sets comprising 226 scans from over five centers. The benchmark includes voxel-level segmentation, CoW component detection, CoW variant classification, and two clinical application tasks. We received submissions from over 250 participants across six continents. Top-performing teams achieved over 90% Dice scores for CoW segmentation, over 80% F1 scores for detecting key vessel components, and over 70% balanced accuracy in CoW variant classification across nearly all test sets. The best algorithms also supported clinically relevant downstream tasks by accurately classifying fetal-type posterior cerebral arteries and localizing aneurysms in relation to CoW anatomy. This benchmark demonstrated the utility of CoW segmentation algorithms for some downstream clinical applications with explainability.

cs.CV↗

Skeleton Recall Loss for Connectivity Conserving and Resource Efficient Segmentation of Thin Tubular Structures

Accurately segmenting thin tubular structures, such as vessels, nerves, roads or concrete cracks, is a crucial task in computer vision. Standard deep learning-based segmentation loss functions, such as Dice or Cross-Entropy, focus on volumetric overlap, often at the expense of preserving structural connectivity or topology. This can lead to segmentation errors that adversely affect downstream tasks, including flow calculation, navigation, and structural inspection. Although current topology-focused losses mark an improvement, they introduce significant computational and memory overheads. This is particularly relevant for 3D data, rendering these losses infeasible for larger volumes as well as increasingly important multi-class segmentation problems. To mitigate this, we propose a novel Skeleton Recall Loss, which effectively addresses these challenges by circumventing intensive GPU-based calculations with inexpensive CPU operations. It demonstrates overall superior performance to current state-of-the-art approaches on five public datasets for topology-preserving segmentation, while substantially reducing computational overheads by more than 90%. In doing so, we introduce the first multi-class capable loss function for thin structure segmentation, excelling in both efficiency and efficacy for topology-preservation.

eess.IV↗

Mitigating False Predictions In Unreasonable Body Regions

Despite considerable strides in developing deep learning models for 3D medical image segmentation, the challenge of effectively generalizing across diverse image distributions persists. While domain generalization is acknowledged as vital for robust application in clinical settings, the challenges stemming from training with a limited Field of View (FOV) remain unaddressed. This limitation leads to false predictions when applied to body regions beyond the FOV of the training data. In response to this problem, we propose a novel loss function that penalizes predictions in implausible body regions, applicable in both single-dataset and multi-dataset training schemes. It is realized with a Body Part Regression model that generates axial slice positional scores. Through comprehensive evaluation using a test set featuring varying FOVs, our approach demonstrates remarkable improvements in generalization capabilities. It effectively mitigates false positive tumor predictions up to 85% and significantly enhances overall segmentation performance.

eess.IV↗

SAM.MD: Zero-shot medical image segmentation capabilities of the Segment Anything Model

Foundation models have taken over natural language processing and image generation domains due to the flexibility of prompting. With the recent introduction of the Segment Anything Model (SAM), this prompt-driven paradigm has entered image segmentation with a hitherto unexplored abundance of capabilities. The purpose of this paper is to conduct an initial evaluation of the out-of-the-box zero-shot capabilities of SAM for medical image segmentation, by evaluating its performance on an abdominal CT organ segmentation task, via point or bounding box based prompting. We show that SAM generalizes well to CT data, making it a potential catalyst for the advancement of semi-automatic segmentation tools for clinicians. We believe that this foundation model, while not reaching state-of-the-art segmentation performance in our investigations, can serve as a highly potent starting point for further adaptations of such models to the intricacies of the medical domain. Keywords: medical image segmentation, SAM, foundation models, zero-shot learning

eess.IV↗