SearcharxivSearch

arXiv subjects

Maya Gates

Publications and source records attributed to Maya Gates.

5 recordsLinked to original sources

Helium-Cooled Cryogenic STEM Imaging and Ptychography for Atomic-Scale Study of Low-Temperature Phases

Much of the exotic functionality of prime interest in quantum materials emerges from structural and electronic ground states that can only be accessed at cryogenic temperatures. Understanding device operation therefore requires structural characterization under the same low-temperature conditions at which these functional phases exist, as room-temperature measurements often probe a different structural state. Achieving atomic-resolution in scanning transmission electron microscopy imaging and particularly 4D-STEM electron ptychography at liquid helium temperature has remained extremely challenging because even small amounts of drift, vibration, and thermal instability associated with the cryogen can disrupt the stringent stability requirements of atomic-resolution STEM. In this work we demonstrate atomic-resolution STEM and multislice electron ptychography at temperatures as low as 20 K using a commercial helium cooled holder. We find that rapid scans and a multi-stage registration workflow are critical to reducing artifacts associated with cryogenic instability for atomic-resolution imaging, while for ptychography scan position correction including compensation for coupling between probe aberrations and position refinement is necessary for successful reconstructions. Together these results establish a pathway for reliable atomic-resolution STEM and ptychography at low temperature, enabling direct visualization of structural ground states relevant to quantum technology.

cond-mat.mtrl-sci

Nanoscale Polar Landscapes in Quantum Paraelectric SrTiO3

SrTiO3 is a textbook quantum paraelectric, with ferroelectricity purportedly suppressed by quantum fluctuations of ionic positions down to the lowest temperatures. The precise real space structure of SrTiO3 at low temperature, however, has remained undefined despite decades of study. Here we directly image the low-temperature polar structure of quantum parelectric SrTiO3, using cryogenic scanning transmission electron microscopy down to 20 K. High resolution imaging reveals a spatially fluctuating landscape of nanoscale domains of finite polarization. The short-range polar domains first grow and self-organize into a periodic structure over tens of nanometers. However, the process reverses when entering the quantum paraelectric regime below 40 K and the periodically ordered polar nanodomains fragment into small clusters.

cond-mat.mtrl-sci

Melting point depression of charge density wave in 1T-TiSe$_2$ due to size effects

Classical nucleation theory predicts size-dependent nucleation and melting due to surface and confinement effects at the nanoscale. In correlated electronic states, observation of size-dependent nucleation and melting is rarely reported, likely due to the extremely small length scales necessary to observe such effects for electronic states. Here, using 1T-TiSe$_2$ nanoflakes as a prototypical two-dimensional (2D) charge density wave (CDW) system, we perform in-situ cryogenic electron microscopy with temperature down to 20 K and observe size-dependent nucleation and melting of CDWs. Specifically, we observe a melting point depression of CDW for 1T-TiSe$_2$ flakes with lateral sizes less than 100 nm. By fitting experimental data to a Ginzburg-Landau model, we estimate a zero-temperature correlation length of 10--50 nm, which matches the reported CDW domain size for 1T-TiSe$_2$. As the flake size approaches the correlation length, the divergence of the CDW correlation length near the transition is cut off by the finite flake size, limiting long-range order and thereby lowering the transition temperature. For very small flakes whose size is close to the correlation length, we also observe absence of CDWs, as predicted by the model. We thus show that an electronic phase transition follows classical nucleation theory.

cond-mat.mtrl-sci

Liquid Helium Cryogenic TEM below 1 {\AA}

Next-generation cryogenic transmission electron microscopes (TEM) aim to achieve high-resolution imaging at ultracold sample temperatures (< 90 K) and over extended hold times. Lower temperatures enable atomic-scale characterization with improved beam and dose resilience for organic specimens and access to emergent electronic phases in quantum materials. Side-entry liquid helium cooling stages presently lack the mechanical and thermal stability required to support sub-Angstrom information transfer in modern TEM. Here we demonstrate sub-Angstrom atomic imaging TEM with a side-entry stage at specimen temperatures down to ~20K and with low stage drift and stable hold times.

physics.ins-det

Ultra-Cold Cryogenic TEM with Liquid Helium and High Stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science, but achieving temperatures below the boiling point of liquid nitrogen remains a long-standing aspiration. We introduce an ultra-cold liquid helium transmission electron microscope specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ${\pm}$2 mK thermal stability over many hours, and atomic resolution--setting the stage for a new era of cryogenic electron microscopy.

physics.app-ph