Searcharxiv⌕ Search

arXiv subjects

Md. Arman Hossen

Publications and source records attributed to Md. Arman Hossen.

4 recordsLinked to original sources

Development of next-generation event-driven x-ray hybrid CMOS detectors

The Penn State University High Energy Astrophysics Detector and Instrumentation Lab, in collaboration with Teledyne Imaging Sensors, has developed a next-generation event-driven X-ray hybrid CMOS detector. This detector is an HCD with a 1,024x1,024 array of 21-micron pitch pixels, featuring a comparator in each pixel to enable event-driven readout. While the full frame operation of this detector can reach readout speeds of up to 150 Hz, this event-driven operation allows readout of only those pixels that surpass a user-set charge threshold, enabling effective rates of up to 10 kHz. Here we report on the past detector development efforts at Penn State and describe these new detectors and expected performance improvements.

astro-ph.IM↗

Characterization of Random Telegraph Noise in an H2RG X-ray Hybrid CMOS Detector

Hybrid CMOS detectors (HCDs) have several excellent features as high-performance X-ray detectors, including rapid readout, deep-depletion silicon for high quantum efficiency, radiation hardness, and low power. Random telegraph noise (RTN) is a type of noise that can reduce the performance of HCDs and other CMOS sensors. After finding and quantifying RTN in the recently developed engineering grade Speedster-EXD550 HCDs, this form of noise has also been found in other X-ray HCDs. This paper aims to investigate its presence and characteristics in the relatively mature H2RG X-ray HCD and to compare it with that of the Speedster-EXD550. We use archival data taken with an H2RG X-ray HCD at two different temperatures to determine the percentage of pixels that are being impacted by RTN. We identify RTN in 0.42% of pixels when the detector is operated at 140 K, while we are only able to identify RTN in 0.060% of pixels when the detector is operated at 160 K. We characterize RTN in two Speedster-EXD550 detectors, identifying 5.1% of pixels with RTN in one detector and 7.1% in another, which is significantly more than the H2RG. These results verify the difference between two different HCDs and provide techniques that can be applied to future hybrid CMOS detectors.

astro-ph.IM↗

The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays

The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV gamma-ray CAmera using Micro-calorimeters) that combines focusing gamma-ray optics with a stack of Transition Edge Sensor (TES) microcalorimeter arrays in the focal plane. The 511-CAM detector assembly has a projected 511 keV energy resolution of 390 eV Full Width Half Maximum (FWHM) or better, and improves by a factor of at least 11 on the performance of state-of-the-art Ge-based Compton telescopes. Combining this unprecedented energy resolution with sub-arcmin angular resolutions afforded by Laue lens or channeling optics could make substantial contributions to identifying the origin of the 511 keV emission by discovering and characterizing point sources and measuring line-of-sight velocities of the emitting plasmas.

astro-ph.IM↗

Performance of the X-Calibur Hard X-Ray Polarimetry Mission during its 2018/19 Long-Duration Balloon Flight

X-Calibur is a balloon-borne telescope that measures the polarization of high-energy X-rays in the 15--50keV energy range. The instrument makes use of the fact that X-rays scatter preferentially perpendicular to the polarization direction. A beryllium scattering element surrounded by pixellated CZT detectors is located at the focal point of the InFOCμS hard X-ray mirror. The instrument was launched for a long-duration balloon (LDB) flight from McMurdo (Antarctica) on December 29, 2018, and obtained the first constraints of the hard X-ray polarization of an accretion-powered pulsar. Here, we describe the characterization and calibration of the instrument on the ground and its performance during the flight, as well as simulations of particle backgrounds and a comparison to measured rates. The pointing system and polarimeter achieved the excellent projected performance. The energy detection threshold for the anticoincidence system was found to be higher than expected and it exhibited unanticipated dead time. Both issues will be remedied for future flights. Overall, the mission performance was nominal, and results will inform the design of the follow-up mission XL-Calibur, which is scheduled to be launched in summer 2022.

astro-ph.IM↗