Searcharxiv⌕ Search

arXiv subjects

Med Amine Laribi

Publications and source records attributed to Med Amine Laribi.

9 recordsLinked to original sources

Facade Inspection: Design, Prototyping, and Testing of a Hybrid Cable-Driven Parallel Robot

In the field of architecture, early detection of damage or degradation of building facades has become increasingly vital due to the need for continuous monitoring of structural integrity. Traditional methods, such as visual inspections, are being supplemented by technological advancements, especially in robotics, which offer innovative solutions for more efficient and precise inspections. This work focuses on the development of a five degree of freedom hybrid cable-driven parallel robot designed for vertical facade inspections. A detailed robot's design and CAD modeling, with a particular focus on a torque transmission mechanism that simplifies the motion of two cables using a single motor is presented. Two degrees of freedom are driven by cables, while the remaining three are driven by a Sarrus-type mechanism and a pan-tilt mechanism. The inverse kinematics models are also developed. A prototype is presented, involving additive manufacturing. A control system for tracking a zig-zag trajectory, commonly used in inspection tasks, was experimentally validated.

physics.class-ph↗

Primary Experimental Feedback on a Co-manipulated Robotic System for Assisted Cervical Surgery

Robotic-assisted surgery has emerged as a promising approach to improve surgical ergonomics, precision, and workflow efficiency, particularly in complex procedures such as cervical spine surgery. In this study, we evaluate the performance of a collaborative robotic system designed to assist surgeons in drilling tasks by assessing its accuracy in executing predefined trajectories. A total of 14 drillings were performed by eight experienced cervical surgeons, utilizing a robotic-assisted setup aimed at ensuring stability and alignment. The primary objective of this study is to quantify the deviations in the position and orientation of the drilling tool relative to the planned trajectory, providing insights into the system's reliability and potential impact on clinical outcomes. While the primary function of robotic assistance in surgery is to enhance surgeon comfort and procedural guidance rather than solely optimizing precision, understanding the system's accuracy remains crucial for its effective integration into surgical practices part of this primary experimental feedback, the study offers an in-depth analysis of the co-manipulated robotic system's performance, focusing on the experimental setup and error evaluation methods. The findings of this study will contribute to the ongoing development of robotic-assisted cervical surgery, highlighting both its advantages and areas for improvement in achieving safer and more efficient surgical workflows

cs.RO↗

Feasible Static Workspace Optimization of Tendon Driven Continuum Robot based on Euclidean norm

This paper focuses on the optimal design of a tendon-driven continuum robot (TDCR) based on its feasible static workspace (FSW). The TDCR under consideration is a two-segment robot driven by eight tendons, with four tendon actuators per segment. Tendon forces are treated as design variables, while the feasible static workspace (FSW) serves as the optimization objective. To determine the robot's feasible static workspace, a genetic algorithm optimization approach is employed to maximize a Euclidian norm of the TDCR's tip position over the workspace. During the simulations, the robot is subjected to external loads, including torques and forces. The results demonstrate the effectiveness of the proposed method in identifying optimal tendon forces to maximize the feasible static workspace, even under the influence of external forces and torques.

cs.RO↗

A novel Integrated Motion Tracking Device (IMTD) for Objective Laparoscopic Training Assessment: Development and Validation

This paper presents a novel, compact four-degree-of-freedom motion-tracking device (IMTD) designed for training and evaluation in laparoscopic surgery. The device's kinematics, mechanical design, instrumentation, and prototypes are developed and presented to meet the specific requirements of laparoscopic training context, including movement around a fixed center of motion and seamless integration into standard box trainers. The system IMTD's tracking accuracy and reliability are compared to a motion capture system (MoCap), assessing its ability to capture both angular and translational motions of surgical instruments. The study then focuses on key performance parameters including precision, fluidity, speed, and overall motion efficiency. The results highlight the system's effectiveness in tracking surgical gestures, providing valuable insights into its potential as a tool for training and performance evaluation in minimally invasive surgery. Additionally, IMTD's low cost and integrated design allow for easy integration and implementation in training rooms, offering a practical and accessible solution for general use. By offering objective, real-time feedback, the system can significantly contribute to improving surgical skills and shortening the learning curve for novice students, while also providing a foundation for future development of gesture scoring algorithms and standardized training protocols.

cs.RO↗

Optimization of an Augmented R-CUBE mechanism for Cervical Surgery

In some surgical operations targeting the spine, it is required to drill cavities in the vertebrae for the insertion of pedicle screws. A new mechanical architecture is proposed for this application. It is based on an augmented version of the full translational R-CUBE mechanism, with improved linkages to implement additional rotational motion. Using this concept, a mechanism presented with a 3T2R motion that is required for the manipulation of the surgical drill. It is mainly composed three stages: one translational, one transmitting and one rotational. Their respective kinematic and velocity models are separately derived, then combined. Based on the drilling trajectories obtained from a real patient case, the mechanism is optimized for generating the highest kinematic performances.

cs.RO↗

Experimental Validation of Light Cable-Driven Elbow-Assisting Device L-CADEL Design

This paper presents a new design of CADEL, a cable-driven elbow-assisting device, with light weighting and control improvements. The new device design is appropriate to be more portable and user-oriented solution, presenting additional facilities with respect to the original design. One of potential benefits of improved portability can be envisaged in the possibility of house and hospital usage keeping social distancing while allowing rehabilitation treatments even during a pandemic spread. Specific attention has been devoted to design main mechatronic components by developing specific kinematics models. The design process includes an implementation of specific control hardware and software. The kinematic model of the new design is formulated and features are evaluated through numerical simulations and experimental tests. An evaluation from original design highlights the proposed improvements mainly in terms of comfort, portability and user-oriented operation.

cs.RO↗

Design and construction of a wireless robot that simulates head movements in cone beam computed tomography imaging

One of the major challenges in the science of maxillofacial radiology imaging is the various artifacts created in images taken by cone beam computed tomography (CBCT) imaging systems. Among these artifacts, motion artifact, which is created by the patient, has adverse effects on image quality. In this paper, according to the conditions and limitations of the CBCT imaging room, the goal is the design and development of a cable-driven parallel robot to create repeatable movements of a dry skull inside a CBCT scanner for studying motion artifacts and building up reference datasets with motion artifacts. The proposed robot allows a dry skull to execute motions, which were selected on the basis of clinical evidence, with 3-degrees of freedom during imaging in synchronous manner with the radiation beam. The kinematic model of the robot is presented to investigate and describe the correlation between the amount of motion and the pulse width applied to DC motors. This robot can be controlled by the user through a smartphone or laptop wirelessly via a Wi-Fi connection. Using wireless communication protects the user from harmful radiation during robot driving and functioning. The results show that the designed robot has a reproducibility above 95% in performing various movements.

physics.med-ph↗

A five-bar mechanism to assist finger flexion-extension movement: system implementation

The lack of specialized personnel and assistive technology to assist in rehabilitation therapies is one of the challenges facing the health sector today, and it is projected to increase. For researchers and engineers, it represents an opportunity to innovate and develop devices that improve and optimize rehabilitation services for the benefit of society. Among the different types of injuries, hand injuries occur most frequently. These injuries require a rehabilitation process in order for the hand to regain its functionality. This article presents the fabrication and instrumentation of an end-effector prototype, based on a five-bar configuration, for finger rehabilitation that executes a natural flexion-extension movement. The dimensions were obtained through the gradient method optimization and evaluated through Matlab. Experimental tests were carried out to demonstrate the prototype's functionality and the effectiveness of a five-bar mechanism acting in a vertical plane, where gravity influences the mechanism's performance. Position control using fifth-order polynomials with via points was implemented in the joint space. The design of the end-effector was also evaluated by performing a theoretical comparison, calculated as a function of a real flexion-extension trajectory of the fingers and the angle of rotation obtained through an IMU. As a result, controlling the two degrees of freedom of the mechanism at several points of the trajectory assures the end-effector trajectory and therefore the fingers' range of motion, which helps for full patient recovery.

cs.RO↗

Development of a novel hybrid haptic (nHH) device with a remote center of rotation dedicated to laparoscopic surgery

This paper focuses on developing a novel hybrid-haptic (nHH) device with a remote center of rotation with 4 DOFs (degrees of freedom) intendant to be used as a haptic device. The new architecture is composed of two chains handling each one a part of the motions. It has the advantages of a parallel robot as high stiffness and accuracy, and the large workspace of the serial robots. The optimal synthesis of the nHH was performed using real-coded genetic algorithms. The optimization criteria and constraints were established and successively formulated and solved using a mono-objective function. A validation and comparison study were performed between the spherical parallel manipulator and the nHH. The obtained results are promising since the nHH is compared to other similar task devices, such as spherical parallel manipulator, and presents a suitable kinematic performance with a task workspace free singularity inside.

physics.med-ph↗