SearcharxivSearch

arXiv subjects

Meiyun Cao

Publications and source records attributed to Meiyun Cao.

3 recordsLinked to original sources

Applications of Large Language Models in Radiation Oncology: From Workflow Automation to Clinical Intelligence

Large language models (LLMs) have emerged as transformative tools in medicine, with strong capabilities in language understanding, reasoning, and structured information extraction. Radiation oncology is particularly well suited for LLM integration due to its data-intensive workflows, reliance on structured guidelines, and documentation burden. This review summarizes recent applications, including domain-specific fine-tuning for decision support, automated nomenclature standardization, registry curation using autonomous LLM agents, and protocol-aware radiotherapy plan evaluation using modular retrieval-augmented generation (RAG). Additional applications include patient safety analysis through incident classification and root cause analysis, electronic health record (EHR)-integrated communication, CT simulation order summarization, daily readiness briefings, and patient education systems. Emerging multimodal approaches enable context-aware contouring, while early studies show LLMs can assist treatment planning by interpreting dosimetric feedback. Together, these advances highlight a shift toward clinically grounded, auditable, and workflow-integrated AI systems that enhance efficiency, safety, and patient engagement.

physics.med-ph

Dose-LET Interactions Predict Capsular Contracture After Proton Postmastectomy Radiation Therapy

Pencil beam scanning (PBS) proton therapy provides highly conformal dose distributions that are increasingly leveraged for postmastectomy radiation therapy (PMRT) to reduce cardiopulmonary exposure. However, implant-based reconstruction in the setting of PMRT remains vulnerable to capsular contracture, and biological mechanisms of possible high linear energy transfer (LET) in PBS have not been well characterized. A retrospective case-control study was conducted on consecutive breast cancer patients who underwent mastectomy followed by implant-based reconstruction and proton PMRT (50 Gy in 25 fractions) between 2015 and 2021. Dose-LET volume histograms (DLVHs) were calculated for peri-implant tissue (5-mm shell around the implant). Generalized linear mixed-effects regression (GLMER) was employed to identify DLVH indices significantly associated with capsular contracture. Spearman correlation analysis was used to eliminate redundance. DLVCs were derived from receiver operating characteristic (ROC) analysis and validated using support vector machine (SVM)-based normal tissue complication probability (NTCP) model. Eight capsular contracture and 16 matched controls patients were analyzed. Three independent and significant DLVH indices were identified(p<0.01). The corresponding DLVCs were: V(55.8 Gy[RBE=1.1], 2.2 keV/μm) < 0.0033%, V(50.3 Gy[RBE=1.1], 5.4 keV/μm) < 0.0017%, and V(32.8 Gy[RBE=1.1], 0.9 keV/μm) > 96.98%. The SVM-based NTCP model achieved an area under the ROC curve (AUROC) of 0.867, with 91.7% accuracy, 87.5% sensitivity, and 93.8% specificity. Capsular contracture following proton PMRT is significantly associated with the synergistic interplay between dose and LETd in peri-implant tissue. The derived DLVCs provide actionable dosimetric constraints that can be integrated into treatment planning to minimize capsular contracture risk in proton PMRT.

physics.med-ph

Evaluating The Performance of Using Large Language Models to Automate Summarization of CT Simulation Orders in Radiation Oncology

Purpose: This study aims to use a large language model (LLM) to automate the generation of summaries from the CT simulation orders and evaluate its performance. Materials and Methods: A total of 607 CT simulation orders for patients were collected from the Aria database at our institution. A locally hosted Llama 3.1 405B model, accessed via the Application Programming Interface (API) service, was used to extract keywords from the CT simulation orders and generate summaries. The downloaded CT simulation orders were categorized into seven groups based on treatment modalities and disease sites. For each group, a customized instruction prompt was developed collaboratively with therapists to guide the Llama 3.1 405B model in generating summaries. The ground truth for the corresponding summaries was manually derived by carefully reviewing each CT simulation order and subsequently verified by therapists. The accuracy of the LLM-generated summaries was evaluated by therapists using the verified ground truth as a reference. Results: About 98% of the LLM-generated summaries aligned with the manually generated ground truth in terms of accuracy. Our evaluations showed an improved consistency in format and enhanced readability of the LLM-generated summaries compared to the corresponding therapists-generated summaries. This automated approach demonstrated a consistent performance across all groups, regardless of modality or disease site. Conclusions: This study demonstrated the high precision and consistency of the Llama 3.1 405B model in extracting keywords and summarizing CT simulation orders, suggesting that LLMs have great potential to help with this task, reduce the workload of therapists and improve workflow efficiency.

physics.med-ph