Mekhail Anwar

Publications and source records attributed to Mekhail Anwar.

4 recordsLinked to original sources

Configurable {\gamma} Photon Spectrometer to Enable Precision Radioguided Tumor Resection

Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma ({\gamma}) photon emitting radioisotopes to identify them, but require a mm-scale {\gamma} photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident {\gamma} photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based {\gamma} spectrometer implemented in 180 nm CMOS, to enable the measurement of single {\gamma} photons and their incident energy with sub-keV energy resolution. We use small 2 2 um reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident {\gamma} photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a {\gamma} detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common {\gamma}-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 uCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.

eess.IV

A Versatile Optical Frontend for Multicolor Fluorescence Imaging with Miniaturized Lensless Sensors

Lensless imaging enables exceptionally compact fluorescence sensors, advancing applications in \textit{in vivo} imaging and low-cost, point-of-care diagnostics. These sensors require a filter to block the excitation light while passing fluorescent emissions. However, conventional thin-film interference filters are sensitive to angle of incidence (AOI), complicating their use in lensless systems. Here we thoroughly analyze and optimize a technique using a fiber optic plate (FOP) to absorb off-axis light that would bleed through the interference filter while improving image resolution. Through simulations, we show that the numerical aperture (NA) of the FOP drives inherent design tradeoffs: collection efficiency improves rapidly with a higher NA, but at the cost of resolution, increased device thickness, and fluorescence excitation efficiency. To illustrate this, we optimize two optical frontends with full-width at half maximums (FWHMs) of 8.3{\deg} and 45.7{\deg}. Implementing these designs, we show that angle-insensitivity requires filters on both sides of the FOP, due to scattering. In imaging experiments, the 520-$\mu$m-thick high-NA design is 59$\times$ more sensitive to fluorescence while only degrading resolution by 3.2$\times$. Alternatively, the low-NA design is capable of three-color fluorescence imaging with 110-$\mu$m resolution at a 1-mm working distance. Overall, we demonstrate a versatile optical frontend that is adaptable to a range of applications using different fluorophores, illumination configurations, and lensless imaging techniques.

eess.IV

A Wireless, Multicolor Fluorescence Image Sensor Implant for Real-Time Monitoring in Cancer Therapy

Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. This data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a 2.5$\times$5 mm$^2$ CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5 cm depth in oil, harvesting energy with 221 mW/cm$^{2}$ incident US power density (31% of FDA limits) and backscattering data at 13 kbps with a bit error rate <$10^{-6}$. In-situ fluorescence excitation is provided by micro-laser diodes controlled with a programmable on-chip driver. An optical frontend combining a multi-bandpass interference filter and a fiber optic plate provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A 36$\times$40-pixel array captures images with <125 $\mu$m resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in ex vivo mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.

physics.med-ph

A Millimeter-scale Single Charged Particle Dosimeter for Cancer Radiotherapy

This paper presents a millimeter-scale CMOS 64$\times$64 single charged particle radiation detector system for external beam cancer radiotherapy. A 1$\times$1 $μm^2$ diode measures energy deposition by a single charged particle in the depletion region, and the array design provides a large detection area of 512$\times$512 $μm^2$. Instead of sensing the voltage drop caused by radiation, the proposed system measures the pulse width, i.e., the time it takes for the voltage to return to its baseline. This obviates the need for using power-hungry and large analog-to-digital converters. A prototype ASIC is fabricated in TSMC 65 nm LP CMOS process and consumes the average static power of 0.535 mW under 1.2 V analog and digital power supply. The functionality of the whole system is successfully verified in a clinical 67.5 MeV proton beam setting. To our' knowledge, this is the first work to demonstrate single charged particle detection for implantable in-vivo dosimetry.

physics.ins-det