SearcharxivSearch

arXiv subjects

Melina Filzinger

Publications and source records attributed to Melina Filzinger.

9 recordsLinked to original sources

Interspecies clock comparison below $5 \times 10^{-18}$ uncertainty with a transportable clock

We report a measurement of the optical frequency ratio between the $^2\mathrm{S}_{1/2}(F=0)$--${^2\mathrm{F}_{7/2}(F=3)}$ electric-octupole (E3) transition of $^{171}$Yb$^{+}$ and the $^1\mathrm{S}_0$--${^3\mathrm{P}_0}$ transition of $^{87}$Sr, $\nu_{\mathrm{Yb}^{+}}/\nu_\mathrm{Sr} = 1.495\,991\,618\,544\,900\,588\,1(65)$. Reaching a fractional uncertainty of $4.3 \times 10^{-18}$, this result improves upon the previous best by more than a factor of three and is among the few that meet the requirements for interspecies clock comparisons specified by the roadmap towards the redefinition of the SI second. The comparison is between a transportable optical lattice clock and a stationary single-ion clock. It spans a period of nearly two years, during which the transportable clock was intermittently operated off-campus. The ratio was reproducibly measured during four separate campaigns, which are consistent within their statistical uncertainties. The results demonstrate reproducible $10^{-18}$ level operation of the transportable clock and thus validate its application for chronometric geodesy and as a transfer standard for inter-institute clock comparisons, e.g., in the absence of optical fiber links.

physics.atom-ph

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

A multi-ion optical clock with $\mathbf{5 \times 10^{-19}}$ uncertainty

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of $5.3\times10^{-19}$ and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the $10^{-20}$-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of $0.6926711632159660405(20)$, with a statistical uncertainty of $0.9\times10^{-18}$ and a combined uncertainty of $2.9\times 10^{-18}$. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.

physics.atom-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

Excited-state magnetic properties of carbon-like $\text{Ca}^{14+}$

We measured the $g$-factor of the excited state $^3\text{P}_1$ in $\text{Ca}^{14+}$ ion to be $g = 1.499032(6)$ with a relative uncertainty of $4\times10^{-6}$. The magnetic field magnitude is derived from the Zeeman splitting of a $\text{Be}^+$ ion, co-trapped in the same linear Paul trap as the highly charged $\text{Ca}^{14+}$ ion. Furthermore, we experimentally determined the second-order Zeeman coefficient $C_2$ of the $^3\text{P}_0$ - $^3\text{P}_1$ clock transition. For the $m_J=0\rightarrow m_{J'}=0$ transition, we obtain $C_2 = 0.39\pm0.04\text{HzmT}^{-2}$, which is to our knowledge the smallest reported for any atomic transition to date. This confirms the predicted low sensitivity of highly charged ions to higher-order Zeeman effects, making them ideal candidates for high-precision optical clocks. Comparison of the experimental results with our state-of-the art electronic structure calculations shows good agreement, and demonstrates the significance of the frequency-dependent Breit contribution, negative energy states and QED effects on magnetic moments.

physics.atom-ph

Probing new bosons and nuclear structure with ytterbium isotope shifts

In this Letter, we present mass-ratio measurements on highly charged Yb$^{42+}$ ions with a precision of $4\times 10^{-12}$ and isotope-shift measurements on Yb$^{+}$ on the $^{2}$S$_{1/2}$ $\to$ $^{2}$D$_{5/2}$ and $^{2}$S$_{1/2}$ $\to$ $^{2}$F$_{7/2}$ transitions with a precision of $4\times 10^{-9}$ for the isotopes $^{168,170,172,174,176}$Yb. We present a new method that allows us to extract higher-order changes in the nuclear charge distribution along the Yb isotope chain, benchmarking ab-initio nuclear structure calculations. Additionally, we perform a King plot analysis to set bounds on a fifth force in the keV$/c^2$ to MeV$/c^2$ range coupling to electrons and neutrons.

physics.atom-ph

Ultralight Dark Matter Search with Space-Time Separated Atomic Clocks and Cavities

We devise and demonstrate a method to search for non-gravitational couplings of ultralight dark matter to standard model particles using space-time separated atomic clocks and cavity-stabilized lasers. By making use of space-time separated sensors, which probe different values of an oscillating dark matter field, we can search for couplings that cancel in typical local experiments. This provides sensitivity to both the temporal and spatial fluctuations of the field. We demonstrate this method using existing data from a frequency comparison of lasers stabilized to two optical cavities connected via a 2220 km fiber link [Schioppo et al., Nat. Commun. 13, 212 (2022)], and from the atomic clocks on board the Global Position System satellites. Our analysis results in constraints on the coupling of scalar dark matter to electrons, d_me, for masses between 1e-19 eV/c^2 and 2e-15 eV/c^2. These are the first constraints on d_me alone in this mass range.

hep-ph

Oscillating nuclear charge radii as sensors for ultralight dark matter

We show that coupling of ultralight dark matter (UDM) to quarks and gluons would lead to an oscillation of the nuclear charge radius for both the quantum chromodynamics (QCD) axion and scalar dark matter. Consequently, the resulting oscillation of electronic energy levels could be resolved with optical atomic clocks, and their comparisons can be used to investigate UDM-nuclear couplings, which were previously only accessible with other platforms. We demonstrate this idea using the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric octupole and ${}^2S_{1/2} (F=0)\leftrightarrow \,{}^2D_{3/2} (F=2)$ electric quadrupole transitions in ${}^{171}Yb^+$. Based on the derived sensitivity coefficients for these two transitions and a long-term comparison of their frequencies using a single trapped ${}^{171}Yb^+$ ion, we find bounds on the scalar UDM-nuclear couplings and the QCD axion decay constant. These results are at a similar level compared to the tightest spectroscopic limits, and future investigations, also with other optical clocks, promise significant improvements.

hep-ph

Rapid production of defect-free beryllium ion Coulomb crystals

Trapped atomic ions find wide applications ranging from precision measurement to quantum information science and quantum computing. Among the different atomic species employed, beryllium ions are widely used due to its light mass and convenient atomic structure. However, the ion loading process requires a high temperature for sufficient vapor pressure, generating undesirable gas load for the background vacuum and limiting the lifetime of a long ion chain. Here, we demonstrate a simple method to rapidly produce pure linear chains of beryllium ions with pulsed laser ablation, serving as a starting point for large-scale quantum information processing. Our method is fast compared to thermal ovens; reduces the vacuum load to only 10^(-12) Torr level; yields a short recovery time of a few seconds; and also eliminates the need for a deep ultraviolet laser for photo-ionization. In addition, we apply feedback control to obtain defect-free ion arrays with desirable lengths.

physics.atom-ph