SearcharxivSearch

arXiv subjects

Mengchao Liu

Publications and source records attributed to Mengchao Liu.

8 recordsLinked to original sources

Mixing plant for JUNO liquid scintillator: Design, construction, installation and commissioning

The most challenging part of building the Jiangmen Underground Neutrino Observatory (JUNO) is the production of 20 kilotons of ultra pure Liquid Scintillator (LS). This paper presents the design, construction, installation, and commissioning of the LS Mixing Plant, a core facility dedicated to blending the primary organic solvent (LAB) with essential functional solutes (PPO, bis-MSB, and BHT). The main purpose of the Mixing Plant is to prepare and purify the concentrated Master Solution (MS) to achieve a low radioactive contamination background. The amount of radioactive contaminants in the MS are lowered by approximately two orders of magnitude after acid and water extraction, followed by a multi-stage filtration procedure. The purified MS is mixed with LAB and then diluted into the LS for JUNO experiments. Commissioning results of the LS verify that the Mixing Plant achieved its design goal, delivering ultra pure LS that satisfies the stringent radiopurity requirements for neutrino physics.

physics.ins-det

A Methanol-mediated Room-Temperature Synthesis of Tellurium-Loaded Liquid Scintillators for Neutrinoless Double Beta Decay Search

This study establishes a methanol-mediated room-temperature synthesis approach for tellurium-diol (Te-diol) compounds for use in tellurium-loaded liquid scintillator (Te-LS). The synthesis involves the direct reaction of telluric acid with diols (e.g., 1,2-hexanediol) in methanol (MeOH) under ambient conditions (25$\pm$5\textdegree C), with the key features of lower energy consumption and enhanced safety compared with high-temperature azeotropic distillation method. Mechanistic studies reveal that MeOH serves not merely as a solvent but also exhibits a catalytic effect, playing a dual role in this water-free, heterogeneous room-temperature synthesis. The Te-diol compounds enable fabrication of high-performance Te samples exhibiting exceptional optical transparency (attenuation length = 20.1$\pm$1.1 m at $\lambda$=430 nm for 1\% Te mass loading), which is reported here for the first time. Furthermore, the Te-LS achieves long-term spectral stability approaching or exceeding one year for both 1\% and 3\% Te mass loadings, and demonstrates a light yield comparable those of both the azeotropic distillation method and the SNO+ collaboration's Type I loading method, albeit modestly lower than that of their Type II method. The developed protocol offers the potential for a more energy efficient alternative for large-scale Te-LS production, particularly valuable for next-generation neutrinoless double-beta decay experiments.

physics.ins-det

Calibration Strategy of the JUNO-TAO Experiment

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

physics.ins-det

Development of water extraction system for liquid scintillatorpurification of JUNO

The Jiangmen Underground Neutrino Observatory (JUNO) uses 20k tons of liquid scintillator (LS)to detect neutrinos. The content of radioactive substances in the liquid scintillator will affect theexperimental results. JUNO will use counter current water extraction to reduce the radioactive metalions inside the LS. In this article, The factors that affect the final water extraction like the partitioncoefficient and the factors that affect it, the optimal mass transfer droplet size, the flow rate ratio,theoretical stage and different working mode (LS as continuous phase or dispersed phase) have beenstudied. We built counter current extraction prototype in the laboratory and a pilot plant in Daya Bay.We not only study the factors above, but also get a lot of engineering experience that worth sharing.

physics.ins-det

A liquid scintillator for a neutrino Detector working at -50 degree

A liquid scintillator (LS) is developed for the Taishan Antineutrino Observatory (TAO), a ton-level neutrino detector to measure the reactor antineutrino spectrum with sub-percent energy resolution by adopting Silicon Photomultipliers (SiPMs) as photosensor. To reduce the dark noise of SiPMs to an acceptable level, the LS has to work at -50 degree or lower. A customized apparatus based on a charge-coupled device (CCD) is developed to study the transparency of the liquid samples in a cryostat. We find that the water content in LS results in transparency degradation at low temperature, which can be cured by bubbling dry nitrogen to remove water. Adding 0.05% ethanol as co-solvent cures the solubility decrease problem of the fluors PPO and bis-MSB at low temperature. Finally, a Gadoliniumdoped liquid scintillator (GdLS), with 0.1% Gd by weight, 2 g/L PPO, 1 mg/L bis-MSB, and 0.05% ethanol by weight in the solvent LAB, shows good transparency at -50 degree and also good light yield.

physics.ins-det

The replacement system of the JUNO liquid scintillator pilot experiment at Daya Bay

The Jiangmen Underground Neutrino Observatory (JUNO), a multi-purpose neutrino experiment, will use 20 kt liquid scintillator (LS). To achieve the physics goal of determining the neutrino mass ordering, 3$\%$ energy resolution at 1 MeV is required. This puts strict requirements on the LS light yield and the transparency. Four LS purification steps have been designed and mid-scale plants have been built at Daya Bay. To examine the performance of the purified LS and find the optimized LS composition, the purified LS was injected to the antineutrino detector 1 in the experimental hall 1 (EH1-AD1) of the Daya Bay neutrino experiment. To pump out the original gadolinium loaded LS and fill the new LS, a LS replacement system has been built in EH1 in 2017. By replacing the Gd-LS with purified water, then replacing the water with purified LS, the replacement system successfully achieved the designed goal. Subsequently, the fluorescence and the wavelength shifter were added to higher concentrations via the replacement system. The data taken at various LS compositions helped JUNO determine the final LS cocktail. Details of the design, the construction, and the operation of the replacement system are reported in this paper.

physics.ins-det

Artificially Engineered Nanostrain in Iron Chalcogenide Superconductor Thin Film for Enhancing Supercurrent

Although nanoscale deformation, such as nanostrain in iron chalcogenide (FeSexTe1-x, FST) thin films, has attracted attention owing to the enhancement of general superconducting properties, including critical current density (Jc) and critical transition temperature, its formation has proven to be an extremely challenging and complex process thus far. Herein, we successfully fabricated an epitaxial FST thin film with uniformly distributed nanostrain by injection of a trace amount of CeO2 inside FST matrix using sequential pulsed laser deposition. Using transmission electron microscopy and geometrical phase analysis, we verified that a trace amount of CeO2 injection forms nanoscale fine defects with a nanostrained region, which has a tensile strain (ezz ~ 0.02) along the c-axis of the FST matrix. The nanostrained FST thin film achieves a remarkable Jc of 3.5 MA/cm2 for a self-field at 6 K and a highly enhanced Jc under the entire magnetic field with respect to a pristine FST thin film.

cond-mat.supr-con

Atomic-scale structure and chemistry of YIG/GGG Interface

Y3Fe5O12 (YIG) is a promising candidate for spin wave devices. In the thin film devices, the interface between YIG and substrate may play important roles in determining the device properties. Here, we use spherical aberration-corrected scanning electron microscopy and spectroscopy to study the atomic arrangement, chemistry and electronic structure of the YIG/Gd3Ga5O12 (GGG) interface. We find that the chemical bonding of the interface is FeO-GdGaO and the interface remains sharp in both atomic and electronic structures. These results provide necessary information for understanding the properties of interface and also for atomistic calculation.

cond-mat.mtrl-sci