SearcharxivSearch

arXiv subjects

Mengzhou Li

Publications and source records attributed to Mengzhou Li.

18 recordsLinked to original sources

Unveiling the anisotropy of linear and nonlinear charge-spin conversion in Weyl semimetal TaIrTe4

In Weyl semimetals, the nonlinear planar Hall effect (NPHE) and spin-orbit torque (SOT) are prominent manifestations of nonlinear and linear charge-spin conversion, respectively. However, simultaneous investigations of these phenomena within a single material system are scarce, limiting our understanding of their intrinsic connection and underlying mechanisms. Here, we report the first simultaneous observation of NPHE and SOT in a TaIrTe4/Py heterostructure. By employing harmonic Hall measurements and developing a magnetic field-dependent method, we successfully separated the contributions from NPHE, field-like SOT, and damping-like SOT, enabling accurate characterization of both linear and nonlinear charge-spin conversion properties. Our experiments revealed significant anisotropy along the [100] and [010] crystallographic directions of TaIrTe4, with stronger nonlinear responses and field-like SOT along the [100] direction, and larger damping-like SOT along the [010] direction. The distinct directional dependence of these phenomena provides new insights into the interplay between surface and bulk contributions to charge-spin conversion in Weyl semimetals. These findings enhance our understanding of anisotropic charge-spin conversion mechanisms in Weyl semimetals, which may inform future research and development of spintronic devices based on topological materials.

cond-mat.mtrl-sci

A 3D-Printed Table for Hybrid X-ray CT and Optical Imaging of a Live Mouse

Multimodal imaging has shown great potential in cancer research by concurrently providing anatomical, functional, and molecular information in live, intact animals. During preclinical imaging of small animals like mice, anesthesia is required to prevent movement and improve image quality. However, their high surface area-to-body weight ratio predisposes mice, particularly nude mice, to hypothermia under anesthesia. To address this, we developed a detachable mouse scanning table with heating function for hybrid x-ray and optical imaging modalities, without introducing metal artifacts. Specifically, we employed Polylactic Acid (PLA) 3D printing technology to fabricate a customized scanning table, compatible with both CT and optical imaging systems. This innovation enables seamless transportation of the table between different imaging setups, while its detachable design facilitates maintaining a clutter-free operational environment within the imaging systems. This is crucial for accommodating various projects within the same scanner. The table features positioned fixation points to secure mice, ensuring positional consistency across imaging modalities. Additionally, we integrated a carbon nanotube-based heating pad into the table to regulate the body temperature of mice during examinations, providing an ethical and effective temperature maintenance solution. Our evaluations confirmed the table's ability to maintain a 30g water bag at approximately 40$^\circ$C, effectively regulating mouse body temperature to an optimal 36$^\circ$C during preclinical imaging sessions. This scanning table serves as a useful tool in preclinical cancer research, offering a versatile tool that upholds animal welfare standards.

physics.med-ph

3D Photon Counting CT Image Super-Resolution Using Conditional Diffusion Model

This study aims to improve photon counting CT (PCCT) image resolution using denoising diffusion probabilistic models (DDPM). Although DDPMs have shown superior performance when applied to various computer vision tasks, their effectiveness has yet to be translated to high dimensional CT super-resolution. To train DDPMs in a conditional sampling manner, we first leverage CatSim to simulate realistic lower resolution PCCT images from high-resolution CT scans. Since maximizing DDPM performance is time-consuming for both inference and training, especially on high-dimensional PCCT data, we explore both 2D and 3D networks for conditional DDPM and apply methods to accelerate training. In particular, we decompose the 3D task into efficient 2D DDPMs and design a joint 2D inference in the reverse diffusion process that synergizes 2D results of all three dimensions to make the final 3D prediction. Experimental results show that our DDPM achieves improved results versus baseline reference models in recovering high-frequency structures, suggesting that a framework based on realistic simulation and DDPM shows promise for improving PCCT resolution.

cs.CV

Data-driven imaging geometric recovery of ultrahigh resolution robotic micro-CT for in-vivo and other applications

We introduce an ultrahigh-resolution (50\mu m\) robotic micro-CT design for localized imaging of carotid plaques using robotic arms, cutting-edge detector, and machine learning technologies. To combat geometric error-induced artifacts in interior CT scans, we propose a data-driven geometry estimation method that maximizes the consistency between projection data and the reprojection counterparts of a reconstructed volume. Particularly, we use a normalized cross correlation metric to overcome the projection truncation effect. Our approach is validated on a robotic CT scan of a sacrificed mouse and a micro-CT phantom scan, both producing sharper images with finer details than that prior correction.

physics.med-ph

Deep Few-view High-resolution Photon-counting CT at Halved Dose for Extremity Imaging

X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR volumetric PCCT reconstruction has been challenged by the large memory burden, training data scarcity, and domain gap issues. In this paper, we propose a deep learning-based approach for PCCT image reconstruction at halved dose and doubled speed validated in a New Zealand clinical trial. Specifically, we design a patch-based volumetric refinement network to alleviate the GPU memory limitation, train network with synthetic data, and use model-based iterative refinement to bridge the gap between synthetic and clinical data. Our results in a reader study of 8 patients from the clinical trial demonstrate a great potential to cut the radiation dose to half that of the clinical PCCT standard without compromising image quality and diagnostic value.

physics.med-ph

Photon-counting CT using a Conditional Diffusion Model for Super-resolution and Texture-preservation

Ultra-high resolution images are desirable in photon counting CT (PCCT), but resolution is physically limited by interactions such as charge sharing. Deep learning is a possible method for super-resolution (SR), but sourcing paired training data that adequately models the target task is difficult. Additionally, SR algorithms can distort noise texture, which is an important in many clinical diagnostic scenarios. Here, we train conditional denoising diffusion probabilistic models (DDPMs) for PCCT super-resolution, with the objective to retain textural characteristics of local noise. PCCT simulation methods are used to synthesize realistic resolution degradation. To preserve noise texture, we explore decoupling the noise and signal image inputs and outputs via deep denoisers, explicitly mapping to each during the SR process. Our experimental results indicate that our DDPM trained on simulated data can improve sharpness in real PCCT images. Additionally, the disentanglement of noise from the original image allows our model more faithfully preserve noise texture.

eess.IV

Coronary Atherosclerotic Plaque Characterization with Photon-counting CT: a Simulation-based Feasibility Study

Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities. In this work, we report a systematic simulation study of a deep-silicon PCCT scanner with a new clinically-relevant digital plaque phantom with realistic geometrical parameters and chemical compositions. This work investigates the effects of spatial resolution, noise, motion artifacts, radiation dose, and spectral characterization. Our simulation results suggest that the deep-silicon PCCT design provides adequate spatial resolution for visualizing a necrotic core and quantitation of key plaque features. Advanced denoising techniques and aggressive bowtie filter designs can keep image noise to acceptable levels at this resolution while keeping radiation dose comparable to that of a conventional CT scan. The ultrahigh resolution of PCCT also means an elevated sensitivity to motion artifacts. It is found that a tolerance of less than 0.4 mm residual movement range requires the application of accurate motion correction methods for best plaque imaging quality with PCCT.

physics.med-ph

On Expressivity and Trainability of Quadratic Networks

Inspired by the diversity of biological neurons, quadratic artificial neurons can play an important role in deep learning models. The type of quadratic neurons of our interest replaces the inner-product operation in the conventional neuron with a quadratic function. Despite promising results so far achieved by networks of quadratic neurons, there are important issues not well addressed. Theoretically, the superior expressivity of a quadratic network over either a conventional network or a conventional network via quadratic activation is not fully elucidated, which makes the use of quadratic networks not well grounded. Practically, although a quadratic network can be trained via generic backpropagation, it can be subject to a higher risk of collapse than the conventional counterpart. To address these issues, we first apply the spline theory and a measure from algebraic geometry to give two theorems that demonstrate better model expressivity of a quadratic network than the conventional counterpart with or without quadratic activation. Then, we propose an effective training strategy referred to as ReLinear to stabilize the training process of a quadratic network, thereby unleashing the full potential in its associated machine learning tasks. Comprehensive experiments on popular datasets are performed to support our findings and confirm the performance of quadratic deep learning. We have shared our code in \url{https://github.com/FengleiFan/ReLinear}.

cs.LG

Systematic Review on Learning-based Spectral CT

Spectral computed tomography (CT) has recently emerged as an advanced version of medical CT and significantly improves conventional (single-energy) CT. Spectral CT has two main forms: dual-energy computed tomography (DECT) and photon-counting computed tomography (PCCT), which offer image improvement, material decomposition, and feature quantification relative to conventional CT. However, the inherent challenges of spectral CT, evidenced by data and image artifacts, remain a bottleneck for clinical applications. To address these problems, machine learning techniques have been widely applied to spectral CT. In this review, we present the state-of-the-art data-driven techniques for spectral CT.

physics.med-ph

Photon-counting CT thermometry via material decomposition and machine learning

Thermal ablation procedures, such as high intensity focused ultrasound (HIFU) and Radiofrequency Ablation (RFA), are often used to eliminate tumors by minimally invasively heating a focal region. For this task, real-time 3D temperature visualization is key to target the diseased tissues while minimizing damage to the surroundings. Current CT thermometry is based on energy-integrated CT, tissue-specific experimental data, and linear relationships between attenuation and temperature. In this letter, we develop a novel approach using photon-counting CT for material decomposition and a neural network to predict temperature based on thermal characteristics of base materials and spectral tomographic measurements of a volume of interest. In our feasibility study, distilled water, 50 mM CaCl2, and 600 mM CaCl2 are chosen as the base materials. Their attenuations are measured in four discrete energy bins at various temperatures. The neural network trained on the experimental data achieves a mean absolute error of 1.80 °C and 3.97 °C on 300 mM CaCl2 and a milk-based protein shake respectively. These experimental results indicate that our approach is promising for handling nonlinear thermal properties for materials that are similar or dissimilar to our base materials.

physics.med-ph

Motion Correction via Locally Linear Embedding for Helical Photon-counting CT

X-ray photon-counting detector (PCD) offers low noise, high resolution, and spectral characterization, representing a next generation of CT and enabling new biomedical applications. It is well known that involuntary patient motion may induce image artifacts with conventional CT scanning, and this problem becomes more serious with PCD due to its high detector pitch and extended scan time. Furthermore, PCD often comes with a substantial number of bad pixels, making analytic image reconstruction challenging and ruling out state-of-the-art motion correction methods that are based on analytical reconstruction. In this paper, we extend our previous locally linear embedding (LLE) cone-beam motion correction method to the helical scanning geometry, which is especially desirable given the high cost of large-area PCD. In addition to our adaption of LLE-based parametric searching to helical cone-beam photon-counting CT geometry, we introduce an unreliable-volume mask to improve the motion estimation accuracy and perform incremental updating on gradually refined sampling grids for optimization of both accuracy and efficiency. Our numerical results demonstrate that our method reduces the estimation errors near the two longitudinal ends of the reconstructed volume and overall image quality. The experimental results on clinical photon-counting scans of the patient extremities show significant resolution improvement after motion correction using our method, which reveals subtle fine structures previously hidden under motion blurring and artifacts.

physics.med-ph

Top-level Design and Simulated Performance of the First Portable CT-MR scanner

Multi-modality imaging hardware can be integrated in a single gantry to collect diverse datasets for complementary information and spatiotemporal correlation, with excellent examples including PET-CT and PET-MRI. However, there is no CT-MRI prototype up to today due to technical challenges and associated cost-benefit considerations. Thanks to the rapid development of medical imaging, it becomes feasible now to integrate cost-effective CT and MRI imagers together for portability, popularity, and point of care. In this paper, we present the top-level design of the first portable CT-MRI system and evaluate its imaging performance via realistic numerical simulations. In this CT-MRI system, the magnet made of two NdFeB rings of about 40.0 cm radius forms a magnetic field of about 57 mT at the isocenter and has a gap of 11.3 cm to accommodate the rotating CT gantry. The targeted MR imaging field of view (FOV) is a sphere of ~15 cm in diameter and that of CT is approximately 20 cm diameter in axial direction and 5 cm in longitudinal direction. Our results show a great potential of such a hybrid system. The proposed CT-MRI system will be valuable in applications such as imaging in underdeveloped countries, disaster scenes and battle fields.

physics.med-ph

Suppression of Correlated Noise with Similarity-based Unsupervised Deep Learning

Image denoising is a prerequisite for downstream tasks in many fields. Low-dose and photon-counting computed tomography (CT) denoising can optimize diagnostic performance at minimized radiation dose. Supervised deep denoising methods are popular but require paired clean or noisy samples that are often unavailable in practice. Limited by the independent noise assumption, current unsupervised denoising methods cannot process correlated noises as in CT images. Here we propose the first-of-its-kind similarity-based unsupervised deep denoising approach, referred to as Noise2Sim, that works in a nonlocal and nonlinear fashion to suppress not only independent but also correlated noises. Theoretically, Noise2Sim is asymptotically equivalent to supervised learning methods under mild conditions. Experimentally, Nosie2Sim recovers intrinsic features from noisy low-dose CT and photon-counting CT images as effectively as or even better than supervised learning methods on practical datasets visually, quantitatively and statistically. Noise2Sim is a general unsupervised denoising approach and has great potential in diverse applications.

cs.LG

On Interpretability of Artificial Neural Networks: A Survey

Deep learning as represented by the artificial deep neural networks (DNNs) has achieved great success in many important areas that deal with text, images, videos, graphs, and so on. However, the black-box nature of DNNs has become one of the primary obstacles for their wide acceptance in mission-critical applications such as medical diagnosis and therapy. Due to the huge potential of deep learning, interpreting neural networks has recently attracted much research attention. In this paper, based on our comprehensive taxonomy, we systematically review recent studies in understanding the mechanism of neural networks, describe applications of interpretability especially in medicine, and discuss future directions of interpretability research, such as in relation to fuzzy logic and brain science.

cs.LG

Soft Autoencoder and Its Wavelet Adaptation Interpretation

Recently, deep learning becomes the main focus of machine learning research and has greatly impacted many important fields. However, deep learning is criticized for lack of interpretability. As a successful unsupervised model in deep learning, the autoencoder embraces a wide spectrum of applications, yet it suffers from the model opaqueness as well. In this paper, we propose a new type of convolutional autoencoders, termed as Soft Autoencoder (Soft-AE), in which the activation functions of encoding layers are implemented with adaptable soft-thresholding units while decoding layers are realized with linear units. Consequently, Soft-AE can be naturally interpreted as a learned cascaded wavelet shrinkage system. Our denoising experiments demonstrate that Soft-AE not only is interpretable but also offers a competitive performance relative to its counterparts. Furthermore, we propose a generalized linear unit (GenLU) to make an autoencoder more adaptive in nonlinearly filtering images and data, such as denoising and deblurring.

cs.LG

Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning

While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary example. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) system design integrating conventional spiral cone-beam CT, contemporary interior tomography, deep learning techniques, and technologies of micro-focus X-ray source, photon-counting detector (PCD), and robotic arms for ultrahigh resolution localized tomography of a freely-selected volume of interest (VOI) at a minimized radiation dose level. The whole system consists of a standard CT scanner for a clinical CT exam and VOI specification, and a robotic-arm based micro-CT scanner for a local scan at much higher spatial and spectral resolution as well as much reduced radiation dose. The prior information from global scan is also fully utilized for background compensation to improve interior tomography from local data for accurate and stable VOI reconstruction. Our results and analysis show that the proposed hybrid reconstruction algorithm delivers superior local reconstruction, being insensitive to the misalignment of the isocenter position and initial view angle in the data/image registration while the attenuation error caused by scale mismatch can be effectively addressed with bias correction. These findings demonstrate the feasibility of our system design. We envision that deep learning techniques can be leveraged for optimized imaging performance. With high resolution imaging, high dose efficiency and low system cost synergistically, our proposed CMCT system has great potentials in temporal bone imaging as well as various other clinical applications.

physics.med-ph

Low-dimensional Manifold Constrained Disentanglement Network for Metal Artifact Reduction

Deep neural network based methods have achieved promising results for CT metal artifact reduction (MAR), most of which use many synthesized paired images for training. As synthesized metal artifacts in CT images may not accurately reflect the clinical counterparts, an artifact disentanglement network (ADN) was proposed with unpaired clinical images directly, producing promising results on clinical datasets. However, without sufficient supervision, it is difficult for ADN to recover structural details of artifact-affected CT images based on adversarial losses only. To overcome these problems, here we propose a low-dimensional manifold (LDM) constrained disentanglement network (DN), leveraging the image characteristics that the patch manifold is generally low-dimensional. Specifically, we design an LDM-DN learning algorithm to empower the disentanglement network through optimizing the synergistic network loss functions while constraining the recovered images to be on a low-dimensional patch manifold. Moreover, learning from both paired and unpaired data, an efficient hybrid optimization scheme is proposed to further improve the MAR performance on clinical datasets. Extensive experiments demonstrate that the proposed LDM-DN approach can consistently improve the MAR performance in paired and/or unpaired learning settings, outperforming competing methods on synthesized and clinical datasets.

eess.IV

X-ray Photon-Counting Data Correction through Deep Learning

X-ray photon-counting detectors (PCDs) are drawing an increasing attention in recent years due to their low noise and energy discrimination capabilities. The energy/spectral dimension associated with PCDs potentially brings great benefits such as for material decomposition, beam hardening and metal artifact reduction, as well as low-dose CT imaging. However, X-ray PCDs are currently limited by several technical issues, particularly charge splitting (including charge sharing and K-shell fluorescence re-absorption or escaping) and pulse pile-up effects which distort the energy spectrum and compromise the data quality. Correction of raw PCD measurements with hardware improvement and analytic modeling is rather expensive and complicated. Hence, here we proposed a deep neural network based PCD data correction approach which directly maps imperfect data to the ideal data in the supervised learning mode. In this work, we first establish a complete simulation model incorporating the charge splitting and pulse pile-up effects. The simulated PCD data and the ground truth counterparts are then fed to a specially designed deep adversarial network for PCD data correction. Next, the trained network is used to correct separately generated PCD data. The test results demonstrate that the trained network successfully recovers the ideal spectrum from the distorted measurement within $\pm6\%$ relative error. Significant data and image fidelity improvements are clearly observed in both projection and reconstruction domains.

physics.med-ph