Searcharxiv⌕ Search

arXiv subjects

Meritxell Bach Cuadra

Publications and source records attributed to Meritxell Bach Cuadra.

At least 19 recordsLinked to original sources

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

physics.med-ph↗

Evaluating Synthetic Data Generation for Domain Generalization in Fetal Brain MRI Segmentation

Fetal brain tissue segmentation from magnetic resonance imaging (MRI) is crucial for studying neurodevelopment, but remains challenging due to data heterogeneity and limited annotations. Domain randomization (DR) has recently emerged as a promising strategy for single-source domain generalization by synthesizing training images with randomized artifacts, contrast, and resolution. In this work, we investigate how to maximize the out-of-domain (OOD) generalization of DR-based methods. We evaluate several synthetic data generation strategies for DR, with a particular focus on our recently proposed framework, FetalSynthSeg. We show that simple Gaussian mixture-based intensity modeling outperforms more complex physics-based simulations, and that intensity clustering (subdividing tissue classes based on intensity) improves OOD robustness. Evaluated on 348 fetal subjects from four sites spanning 0.55-3T and both T1w and T2w contrasts, FetalSynthSeg reaches state-of-the-art performance on several FeTA 2024 testing datasets (80-85 Dice score) and, for the first time, offers robust segmentation on modalities other than T2w for fetal brain segmentation (80 Dice on dHCP-T1w dataset). Compared with state-of-the-art methods such as BOUNTI, nnU-Net ensemble, and the FeTA 2024 winner, FetalSynthSeg delivers comparable or superior accuracy while maintaining strong robustness across domain shifts. Our code, model weights, and Docker image ready for easy inference are available at https://hub.docker.com/r/vzalevskyi/fetalsynthseg.

eess.IV↗

Towards Brain MRI Foundation Models for the Clinic: Findings from the FOMO25 Challenge

Clinical deployment of automated brain MRI analysis faces a fundamental challenge: clinical data is heterogeneous and noisy, and high-quality labels are prohibitively costly to obtain. Self-supervised learning (SSL) can address this by leveraging the vast amounts of unlabeled data produced in clinical workflows to train robust \textit{foundation models} that adapt out-of-domain with minimal supervision. However, the development of foundation models for brain MRI has been limited by small pretraining datasets and in-domain benchmarking focused on high-quality, research-grade data. To address this gap, we organized the FOMO25 challenge as a satellite event at MICCAI 2025. FOMO25 provided participants with a large pretraining dataset, FOMO60K, and evaluated models on data sourced directly from clinical workflows in few-shot and out-of-domain settings. Tasks covered infarct classification, meningioma segmentation, and brain age regression, and considered both models trained on FOMO60K (method track) and any data (open track). Nineteen foundation models from sixteen teams were evaluated using a standardized containerized pipeline. Results show that (a) self-supervised pretraining improves generalization on clinical data under domain shift, with the strongest models trained \textit{out-of-domain} surpassing supervised baselines trained \textit{in-domain}. (b) No single pretraining objective benefits all tasks: MAE favors segmentation, hybrid reconstruction-contrastive objectives favor classification, and (c) strong performance was achieved by small pretrained models, and improvements from scaling model size and training duration did not yield reliable benefits.

cs.CV↗

Explaining Uncertainty in Multiple Sclerosis Cortical Lesion Segmentation Beyond Prediction Errors

Trustworthy artificial intelligence (AI) is essential in healthcare, particularly for high-stakes tasks like medical image segmentation. Explainable AI and uncertainty quantification significantly enhance AI reliability by addressing key attributes such as robustness, usability, and explainability. Despite extensive technical advances in uncertainty quantification for medical imaging, understanding the clinical informativeness and interpretability of uncertainty remains limited. This study presents an interpretability framework for analyzing lesion-scale predictive uncertainty in cortical lesion segmentation in multiple sclerosis using deep ensembles. The analysis shifts the focus from the uncertainty--error relationship towards clinically relevant medical and engineering factors. Our findings reveal that instance-wise uncertainty is strongly related to lesion size, shape, and cortical involvement. Expert rater feedback confirms that similar factors impede annotator confidence. Evaluations conducted on two datasets (206 patients, almost 2000 lesions) under both in-domain and distribution-shift conditions highlight the utility of the framework in different scenarios.

eess.IV↗

Fetpype: An Open-Source Pipeline for Reproducible Fetal Brain MRI Analysis

Fetal brain magnetic resonance imaging (MRI) is crucial for assessing neurodevelopment in utero. However, fetal MRI analysis remains technically challenging due to fetal motion, low signal-to-noise ratio, and the need for complex multi-step processing pipelines. These pipelines typically include motion correction, super-resolution reconstruction, tissue segmentation, and cortical surface extraction. While specialized tools exist for each individual processing step, integrating them into a robust, reproducible, and user-friendly end-to-end workflow remains difficult. This fragmentation limits reproducibility across studies and hinders the adoption of advanced fetal neuroimaging methods in both research and clinical contexts. Fetpype addresses this gap by providing a standardized, modular, and reproducible framework for fetal brain MRI preprocessing and analysis, enabling researchers to process raw T2-weighted acquisitions through to derived volumetric and surface-based outputs within a unified workflow. Fetpype is publicly available on GitHub at https://github.com/fetpype/fetpype.

eess.IV↗

Towards contrast- and pathology-agnostic clinical fetal brain MRI segmentation using SynthSeg

Magnetic resonance imaging (MRI) has played a crucial role in fetal neurodevelopmental research. Structural annotations of MR images are an important step for quantitative analysis of the developing human brain, with Deep Learning providing an automated alternative for this otherwise tedious manual process. However, segmentation performances of Convolutional Neural Networks often suffer from domain shift, where the network fails when applied to subjects that deviate from the distribution with which it is trained on. In this work, we aim to train networks capable of automatically segmenting fetal brain MRIs with a wide range of domain shifts pertaining to differences in subject physiology and acquisition environments, in particular shape-based differences commonly observed in pathological cases. We introduce a novel data-driven train-time sampling strategy that seeks to fully exploit the diversity of a given training dataset to enhance the domain generalizability of the trained networks. We adapted our sampler, together with other existing data augmentation techniques, to the SynthSeg framework, a generator that utilizes domain randomization to generate diverse training data. We ran thorough experimentations and ablation studies on a wide range of training/testing data to test the validity of the approaches. Our networks achieved notable improvements in the segmentation quality on testing subjects with intense anatomical abnormalities (p < 1e-4), though at the cost of a slighter decrease in performance in cases with fewer abnormalities. Our work also lays the foundation for future works on creating and adapting data-driven sampling strategies for other training pipelines.

eess.IV↗

From 100,000+ images to winning the first brain MRI foundation model challenges: Sharing lessons and models

Developing Foundation Models for medical image analysis is essential to overcome the unique challenges of radiological tasks. The first challenges of this kind for 3D brain MRI, SSL3D and FOMO25, were held at MICCAI 2025. Our solution ranked first in tracks of both contests. It relies on a U-Net CNN architecture combined with strategies leveraging anatomical priors and neuroimaging domain knowledge. Notably, our models trained 1-2 orders of magnitude faster and were 10 times smaller than competing transformer-based approaches. Models are available here: https://github.com/jbanusco/BrainFM4Challenges.

cs.CV↗

Instance-level quantitative saliency in multiple sclerosis lesion segmentation

Explainable artificial intelligence (XAI) methods have been proposed to interpret model decisions in classification and, more recently, in semantic segmentation. However, instance-level XAI for semantic segmentation, namely explanations focused on a single object among multiple instances of the same class, remains largely unexplored. Such explanations are particularly important in multi-lesional diseases to understand what drives the detection and contouring of a specific lesion. We propose instance-level explanation maps for semantic segmentation by extending SmoothGrad and Grad-CAM++ to obtain quantitative instance saliency. These methods were applied to the segmentation of white matter lesions (WMLs), a magnetic resonance imaging biomarker in multiple sclerosis. We used 4023 FLAIR and MPRAGE MRI scans from 687 patients collected at the University Hospital of Basel, Switzerland, with WML masks annotated by four expert clinicians. Three deep learning architectures, a 3D U-Net, nnU-Net, and Swin UNETR, were trained and evaluated, achieving normalized Dice scores of 0.71, 0.78, and 0.80, respectively. Instance saliency maps showed that the models relied primarily on FLAIR rather than MPRAGE for WML segmentation, with positive saliency inside lesions and negative saliency in their immediate neighborhood, consistent with clinical practice. Peak saliency values differed significantly across correct and incorrect predictions, suggesting that quantitative instance saliency may help identify segmentation errors. In conclusion, we introduce two architecture-agnostic XAI methods that provide quantitative instance-level explanations for semantic segmentation and support clinically meaningful interpretation of model decisions.

eess.IV↗

Causal Attribution of Model Performance Gaps in Medical Imaging Under Distribution Shifts

Deep learning models for medical image segmentation suffer significant performance drops due to distribution shifts, but the causal mechanisms behind these drops remain poorly understood. We extend causal attribution frameworks to high-dimensional segmentation tasks, quantifying how acquisition protocols and annotation variability independently contribute to performance degradation. We model the data-generating process through a causal graph and employ Shapley values to fairly attribute performance changes to individual mechanisms. Our framework addresses unique challenges in medical imaging: high-dimensional outputs, limited samples, and complex mechanism interactions. Validation on multiple sclerosis (MS) lesion segmentation across 4 centers and 7 annotators reveals context-dependent failure modes: annotation protocol shifts dominate when crossing annotators (7.4% $\pm$ 8.9% DSC attribution), while acquisition shifts dominate when crossing imaging centers (6.5% $\pm$ 9.1%). This mechanism-specific quantification enables practitioners to prioritize targeted interventions based on deployment context.

eess.IV↗

Accounting for Underspecification in Statistical Claims of Model Superiority

Machine learning methods are increasingly applied in medical imaging, yet many reported improvements lack statistical robustness: recent works have highlighted that small but significant performance gains are highly likely to be false positives. However, these analyses do not take \emph{underspecification} into account -- the fact that models achieving similar validation scores may behave differently on unseen data due to random initialization or training dynamics. Here, we extend a recent statistical framework modeling false outperformance claims to include underspecification as an additional variance component. Our simulations demonstrate that even modest seed variability ($\sim1\%$) substantially increases the evidence required to support superiority claims. Our findings underscore the need for explicit modeling of training variance when validating medical imaging systems.

cs.LG↗

T2 mapping at 0.55 T using Ultra-Fast Spin Echo MRI

Low-field T2 mapping MRI can democratize neuropediatric imaging by improving accessibility and providing quantitative biomarkers of brain development. \textbf{Purpose:} To evaluate the feasibility of high-resolution T2 mapping using a single-shot fast spin-echo (SS-FSE) sequence at 0.55~T in a healthy control cohort. \textbf{Study Type:} Prospective single-center study. \textbf{Population:} In vivo: ten healthy adults (18--43~years, 5 females/5 males). In vitro: NIST Phantom. \textbf{Field strength/sequence:} Multi-echo ultra-fast spin-echo at 0.55~T and 1.5~T. \textbf{Assessment:} Feasibility was first assessed in vitro using the NIST Phantom, comparing T2 relaxation times to spectrometer references at 0.55~T. Acquisition and T2-fitting parameters optimized in vitro were applied in vivo. Repeatability was evaluated by atlas-based analysis of white matter (WM) and cortical grey matter (GM) regions. Coefficients of variation (CoV) were computed across runs, sessions, and subjects. \textbf{Statistical Tests:} Wilcoxon signed-rank test with Bonferroni correction ($α= 0.05/n_{ROI}$) assessed CoV differences. Pearson correlation coefficients quantified T2 associations. \textbf{Results:} In vitro, mono-exponential fitting under Gaussian--Rician noise yielded deviations $<12\%$ from reference values. In vivo, inter-subject CoV was 5.2\% (WM) and 17.7\% (GM), comparable to 1.5~T. Mean T2 times were 118~ms (WM) and 188~ms (GM) at 0.55~T, with a 16.5-minute acquisition. \textbf{Conclusion:} A rapid, robust high-resolution T2 mapping protocol at 0.55~T for HASTE MRI is presented, employing Gaussian noise-based fitting. We report the first normative T2 values for healthy adult brains at 0.55~T, demonstrating technical feasibility and reliability.

physics.app-ph↗

Segmenting infant brains across magnetic fields: Domain randomization and annotation curation in ultra-low field MRI

Early identification of neurodevelopmental disorders relies on accurate segmentation of brain structures in infancy, a task complicated by rapid brain growth, poor tissue contrast, and motion artifacts in pediatric MRI. These challenges are further exacerbated in ultra-low-field (ULF, 0.064~T) MRI, which, despite its lower image quality, offers an affordable, portable, and sedation-free alternative for use in low-resource settings. In this work, we propose a domain randomization (DR) framework to bridge the domain gap between high-field (HF) and ULF MRI in the context of the hippocampi and basal ganglia segmentation in the LISA challenge. We show that pre-training on whole-brain HF segmentations using DR significantly improves generalization to ULF data, and that careful curation of training labels, by removing misregistered HF-to-ULF annotations from training, further boosts performance. By fusing the predictions of several models through majority voting, we are able to achieve competitive performance. Our results demonstrate that combining robust augmentation with annotation quality control can enable accurate segmentation in ULF data. Our code is available at https://github.com/Medical-Image-Analysis-Laboratory/lisasegm

eess.IV↗

Enhancing Corpus Callosum Segmentation in Fetal MRI via Pathology-Informed Domain Randomization

Accurate fetal brain segmentation is crucial for extracting biomarkers and assessing neurodevelopment, especially in conditions such as corpus callosum dysgenesis (CCD), which can induce drastic anatomical changes. However, the rarity of CCD severely limits annotated data, hindering the generalization of deep learning models. To address this, we propose a pathology-informed domain randomization strategy that embeds prior knowledge of CCD manifestations into a synthetic data generation pipeline. By simulating diverse brain alterations from healthy data alone, our approach enables robust segmentation without requiring pathological annotations. We validate our method on a cohort comprising 248 healthy fetuses, 26 with CCD, and 47 with other brain pathologies, achieving substantial improvements on CCD cases while maintaining performance on both healthy fetuses and those with other pathologies. From the predicted segmentations, we derive clinically relevant biomarkers, such as corpus callosum length (LCC) and volume, and show their utility in distinguishing CCD subtypes. Our pathology-informed augmentation reduces the LCC estimation error from 1.89 mm to 0.80 mm in healthy cases and from 10.9 mm to 0.7 mm in CCD cases. Beyond these quantitative gains, our approach yields segmentations with improved topological consistency relative to available ground truth, enabling more reliable shape-based analyses. Overall, this work demonstrates that incorporating domain-specific anatomical priors into synthetic data pipelines can effectively mitigate data scarcity and enhance analysis of rare but clinically significant malformations.

cs.CV↗

Automatic quality control in multi-centric fetal brain MRI super-resolution reconstruction

Quality control (QC) has long been considered essential to guarantee the reliability of neuroimaging studies. It is particularly important for fetal brain MRI, where acquisitions and image processing techniques are less standardized than in adult imaging. In this work, we focus on automated quality control of super-resolution reconstruction (SRR) volumes of fetal brain MRI, an important processing step where multiple stacks of thick 2D slices are registered together and combined to build a single, isotropic and artifact-free T2 weighted volume. We propose FetMRQC$_{SR}$, a machine-learning method that extracts more than 100 image quality metrics to predict image quality scores using a random forest model. This approach is well suited to a problem that is high dimensional, with highly heterogeneous data and small datasets. We validate FetMRQC$_{SR}$ in an out-of-domain (OOD) setting and report high performance (ROC AUC = 0.89), even when faced with data from an unknown site or SRR method. We also investigate failure cases and show that they occur in $45\%$ of the images due to ambiguous configurations for which the rating from the expert is arguable. These results are encouraging and illustrate how a non deep learning-based method like FetMRQC$_{SR}$ is well suited to this multifaceted problem. Our tool, along with all the code used to generate, train and evaluate the model are available at https://github.com/Medical-Image-Analysis-Laboratory/fetmrqc_sr/ .

eess.IV↗

Physics-Informed Joint Multi-TE Super-Resolution with Implicit Neural Representation for Robust Fetal T2 Mapping

T2 mapping in fetal brain MRI has the potential to improve characterization of the developing brain, especially at mid-field (0.55T), where T2 decay is slower. However, this is challenging as fetal MRI acquisition relies on multiple motion-corrupted stacks of thick slices, requiring slice-to-volume reconstruction (SVR) to estimate a high-resolution (HR) 3D volume. Currently, T2 mapping involves repeated acquisitions of these stacks at each echo time (TE), leading to long scan times and high sensitivity to motion. We tackle this challenge with a method that jointly reconstructs data across TEs, addressing severe motion. Our approach combines implicit neural representations with a physics-informed regularization that models T2 decay, enabling information sharing across TEs while preserving anatomical and quantitative T2 fidelity. We demonstrate state-of-the-art performance on simulated fetal brain and in vivo adult datasets with fetal-like motion. We also present the first in vivo fetal T2 mapping results at 0.55T. Our study shows potential for reducing the number of stacks per TE in T2 mapping by leveraging anatomical redundancy.

cs.CV↗

Benchmarking and Explaining Deep Learning Cortical Lesion MRI Segmentation in Multiple Sclerosis

Cortical lesions (CLs) have emerged as valuable biomarkers in multiple sclerosis (MS), offering high diagnostic specificity and prognostic relevance. However, their routine clinical integration remains limited due to subtle magnetic resonance imaging (MRI) appearance, challenges in expert annotation, and a lack of standardized automated methods. We propose a comprehensive multi-centric benchmark of CL detection and segmentation in MRI. A total of 656 MRI scans, including clinical trial and research data from four institutions, were acquired at 3T and 7T using MP2RAGE and MPRAGE sequences with expert-consensus annotations. We rely on the self-configuring nnU-Net framework, designed for medical imaging segmentation, and propose adaptations tailored to the improved CL detection. We evaluated model generalization through out-of-distribution testing, demonstrating strong lesion detection capabilities with an F1-score of 0.64 and 0.5 in and out of the domain, respectively. We also analyze internal model features and model errors for a better understanding of AI decision-making. Our study examines how data variability, lesion ambiguity, and protocol differences impact model performance, offering future recommendations to address these barriers to clinical adoption. To reinforce the reproducibility, the implementation and models will be publicly accessible and ready to use at https://github.com/Medical-Image-Analysis-Laboratory/ and https://doi.org/10.5281/zenodo.15911797.

eess.IV↗

Assessing workflow impact and clinical utility of AI-assisted brain aneurysm detection: a multi-reader study

Despite the plethora of AI-based algorithms developed for anomaly detection in radiology, subsequent integration into clinical setting is rarely evaluated. In this work, we assess the applicability and utility of an AI-based model for brain aneurysm detection comparing the performance of two readers with different levels of experience (2 and 13 years). We aim to answer the following questions: 1) Do the readers improve their performance when assisted by the AI algorithm? 2) How much does the AI algorithm impact routine clinical workflow? We reuse and enlarge our open-access, Time-Of-Flight Magnetic Resonance Angiography dataset (N=460). We use 360 subjects for training/validating our algorithm and 100 as unseen test set for the reading session. Even though our model reaches state-of-the-art results on the test set (sensitivity=74%, false positive rate=1.6), we show that neither the junior nor the senior reader significantly increase their sensitivity (p=0.59, p=1, respectively). In addition, we find that reading time for both readers is significantly higher in the "AI-assisted" setting than in the "Unassisted" (+15 seconds, on average; p=3x10^(-4) junior, p=3x10^(-5) senior). The confidence reported by the readers is unchanged across the two settings, indicating that the AI assistance does not influence the certainty of the diagnosis. Our findings highlight the importance of clinical validation of AI algorithms in a clinical setting involving radiologists. This study should serve as a reminder to the community to always examine the real-word effectiveness and workflow impact of proposed algorithms.

eess.IV↗

ConfLUNet: Multiple sclerosis lesion instance segmentation in presence of confluent lesions

Accurate lesion-level segmentation on MRI is critical for multiple sclerosis (MS) diagnosis, prognosis, and disease monitoring. However, current evaluation practices largely rely on semantic segmentation post-processed with connected components (CC), which cannot separate confluent lesions (aggregates of confluent lesion units, CLUs) due to reliance on spatial connectivity. To address this misalignment with clinical needs, we introduce formal definitions of CLUs and associated CLU-aware detection metrics, and include them in an exhaustive instance segmentation evaluation framework. Within this framework, we systematically evaluate CC and post-processing-based Automated Confluent Splitting (ACLS), the only existing methods for lesion instance segmentation in MS. Our analysis reveals that CC consistently underestimates CLU counts, while ACLS tends to oversplit lesions, leading to overestimated lesion counts and reduced precision. To overcome these limitations, we propose ConfLUNet, the first end-to-end instance segmentation framework for MS lesions. ConfLUNet jointly optimizes lesion detection and delineation from a single FLAIR image. Trained on 50 patients, ConfLUNet significantly outperforms CC and ACLS on the held-out test set (n=13) in instance segmentation (Panoptic Quality: 42.0% vs. 37.5%/36.8%; p = 0.017/0.005) and lesion detection (F1: 67.3% vs. 61.6%/59.9%; p = 0.028/0.013). For CLU detection, ConfLUNet achieves the highest F1[CLU] (81.5%), improving recall over CC (+12.5%, p = 0.015) and precision over ACLS (+31.2%, p = 0.003). By combining rigorous definitions, new CLU-aware metrics, a reproducible evaluation framework, and the first dedicated end-to-end model, this work lays the foundation for lesion instance segmentation in MS.

eess.IV↗