SearcharxivSearch

arXiv subjects

Merlin Kole

Publications and source records attributed to Merlin Kole.

33 records · Page 2Linked to original sources

Gamma-ray Polarimetry of Transient Sources with POLAR

Polarization measurements of the gamma-ray component of transient sources are of great scientific interest, they are however, also highly challenging. This is due to the typical low signal to noise and the potential for significant systematic errors. Both issues are made worse by the transient nature of the events which prompt one to observe a large portion of the sky. The POLAR instrument was designed as a dedicated transient gamma-ray polarimeter. It made use of a large effective area and large field of view to maximize the signal to noise as well as the number of observed transients. Additionally, it was calibrated carefully on ground and in orbit to mitigate systematic errors. The main scientific goal of POLAR was to measure the polarization of the prompt emission of Gamma-Ray Bursts. During the 6 months operation in orbit POLAR observed 55 Gamma-Ray Bursts of which 14 were bright enough to allow for constraining polarization measurements. In this chapter we mainly discuss about the POLAR instrument along with the calibration and analysis procedures. Two analyses are described, the first is a straightforward method previously implemented in polarization measurements, whilst the second was developed to improve the sensitivity and to mitigate several of the issues with the former. Both methods are described in detail along with information on how these can be extended to perform time and energy resolved polarization measurements.

astro-ph.IM

Gamma-Ray Polarimetry of the Crab Pulsar Observed by POLAR

The X/$γ$ ray polarimetry of the Crab pulsar/nebula is believed to hold crucial information on their emission models. In the past, several missions have shown evidence of polarized emission from the Crab. The significance of these measurements remains however limited. New measurements are therefore required. POLAR is a wide Field of View Compton-scattering polarimeter (sensitive in 50-500 keV) onboard the Chinese spacelab Tiangong-2 which took data from September 2016 to April 2017. Although not designed to perform polarization measurements of pulsars, we present here a novel method which can be applied to POLAR as well as that of other wide Field of View polarimeters. The novel polarimetric joint-fitting method for the Crab pulsar observations with POLAR, allows us to obtain constraining measurements of the pulsar component. The best fitted values and corresponding 1$σ$ deviations for the averaged phase interval: (PD=$14\substack{+15 \\ -10}$\%, PA=$108\substack{+33 \\ -54} ^{\circ}$), for Peak 1: (PD=$17\substack{+18 \\ -12}$\%, PA=$174\substack{+39 \\ -36} ^{\circ}$) and for Peak 2: (PD=$16\substack{+16 \\ -11}$\%, PA=$78\substack{+39 \\ -30} ^{\circ}$). Further more, the 3$σ$ upper limits on the polarization degree are for the averaged phase interval (55\%), Peak 1 (66\%) and Peak 2 (57\%). Finally, to illustrate the capabilities of this method in the future, we simulated two years observation to the Crab pulsar with POLAR-2. The results show that POLAR-2 is able to confirm the emission to be polarized with $5σ$ and $4σ$ confidence level if the Crab pulsar is polarized at $20\%$ and $10\%$ respectively.

astro-ph.HE

GRB Polarization: A Unique Probe of GRB Physics

Over half a century from the discovery of gamma-ray bursts (GRBs), the dominant radiation mechanism responsible for their bright and highly variable prompt emission remains poorly understood. Spectral information alone has proven insufficient for understanding the composition and main energy dissipation mechanism in GRB jets. High-sensitivity polarimetric observations from upcoming instruments in this decade may help answer such key questions in GRB physics. This article reviews the current status of prompt GRB polarization measurements and provides comprehensive predictions from theoretical models. A concise overview of the fundamental questions in prompt GRB physics is provided. Important developments in gamma-ray polarimetry including a critical overview of different past instruments are presented. Theoretical predictions for different radiation mechanisms and jet structures are confronted with time-integrated and time-resolved measurements. The current status and capabilities of upcoming instruments regarding the prompt emission are presented. The very complimentary information that can be obtained from polarimetry of X-ray flares as well as reverse-shock and early to late forward-shock (afterglow) emission is highlighted. Finally, promising directions for overcoming the inherent difficulties in obtaining statistically significant prompt-GRB polarization measurements are discussed, along with prospects for improvements in the theoretical modeling, which may lead to significant advances in the field.

astro-ph.HE

Re-evaluation of Lunar X-ray observations by Apollo 15 & 16

The Apollo 15 & 16 missions were the first to explore the Lunar surface chemistry by investigating about 10% of the Lunar surface using a remote sensing X-ray fluorescence spectrometer experiment. The data obtained have been extensively used to study Lunar formation history and geological evolution. In this work, a re-evaluation of the Apollo 15 & 16 X-ray fluorescence experiment is conducted with the aim of obtaining up-to-date empirical values for aluminum (Al) and magnesium (Mg) concentrations relative to silicon (Si) of the upper Lunar surface. An updated instrument response, a newly reconstructed Lunar trajectory orbit, and improved intensity ratio calculations were used to obtain new intensity ratio maps. The resulting Lunar Al/Si and Mg/Al X-ray maps show a clear distinction in Lunar mare and highland regions. The mean Al/Si and Mg/Al intensity ratios for the mare regions obtained from the newly obtained maps are 0.54$\pm$0.07 and 0.54$\pm$0.17, respectively; for the highland regions, the values are 0.76$\pm$0.07 and 1.07$\pm$0.13, respectively. For the Mg/Si intensity ratio, no clear distinction between Lunar features is obtained and we derived a mean value of 0.47$\pm$0.13. Our determined intensity ratios are lower than previously published. These values can be used to infer concentration ratios when accounting for Solar activity, inter-orbit variability, and measurements from different instruments. We employed a correction to infer concentration ratios by comparing our intensity ratios directly to Lunar rock concentrations obtained from various Lunar missions.

astro-ph.EP

The POLAR Gamma-Ray Burst Polarization Catalog

Despite over 50 years of research, many open questions remain about the origin and nature of GRBs. Polarization measurements of the prompt emission of these extreme phenomena have long been thought to be the key to answering a range of these questions. The POLAR detector was designed to produce the first set of detailed and reliable polarization measurements in an energy range of approximately 50-500 keV. During late 2016 and early 2017, POLAR detected a total of 55 GRBs. Analysis results of 5 of these GRBs have been reported in the past. The results were found to be consistent with a low or unpolarized flux. However, previous reports by other collaborations found high levels of polarization. We study the polarization for all the 14 GRBs observed by POLAR for which statistically robust inferences are possible. Additionally, time-resolved polarization studies are performed on GRBs with sufficient apparent flux. A publicly available polarization analysis tool, developed within the 3ML framework, was used to produce statistically robust results. The method allows to combine spectral and polarimetric data from POLAR with spectral data from the Fermi GBM and Swift-BAT to jointly model the spectral and polarimetric parameters. The time integrated analysis finds all results to be compatible with a low or zero polarization with the caveat that, when time-resolved analysis is possible within individual pulses, we observe moderate polarization with a rapidly changing polarization angle. Thus, time-integrated polarization results, while pointing to lower polarization are potentially an artifact of summing over the changing polarization signal and thus, washing out the true moderate polarization. Therefore, we caution against over interpretation of any time-integrated results and encourage one to wait for more detailed polarization measurements from forthcoming missions such as POLAR-2 and LEAP.

astro-ph.HE

Phase-resolved gamma-ray spectroscopy of the Crab pulsar observed by POLAR

The POLAR detector is a space based Gamma-Ray Burst (GRB) polarimeter sensitive in the 15-500 keV energy range. Apart from its main scientific goal as a Gamma-Ray Burst polarimeter it is also able to detect photons from pulsars in orbit. By using the six-months in-orbit observation data, significant pulsation from the PSR B0531+21 (Crab pulsar) was obtained. In this work, we present the precise timing analysis of the Crab pulsar, together with a phase-resolved spectroscopic study using a joint-fitting method adapted for wide field of view instruments like POLAR. By using single power law fitting over the pulsed phase, we obtained spectral indices ranging from 1.718 to 2.315, and confirmed the spectral evolution in a reverse S shape which is homogenous with results from other missions over broadband. We will also show, based on the POLAR in-orbit performance and Geant4 Monte-Carlo simulation, the inferred capabilities of POLAR-2, the proposed follow-up mission of POLAR on board the China Space Station (CSS), for pulsars studies.

astro-ph.IM

Detailed polarization measurements of the prompt emission of five Gamma-Ray Bursts

Gamma-ray bursts are the strongest explosions in the Universe since the Big Bang, believed to be produced either in forming black holes at the end of massive star evolution or merging of compact objects. Spectral and timing properties of gamma-ray bursts suggest that the observed bright gamma-rays are produced in the most relativistic jets in the Universe; however, the physical properties, especially the structure and magnetic topologies in the jets are still not well known, despite several decades of studies. It is widely believed that precise measurements of the polarization properties of gamma-ray bursts should provide crucial information on the highly relativistic jets. As a result there have been many reports of gamma-ray burst polarization measurements with diverse results, see, however many such measurements suffered from substantial uncertainties, mostly systematic. After the first successful measurements by the GAP and COSI instruments, here we report a statistically meaningful sample of precise polarization measurements, obtained with the dedicated gamma-ray burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results suggest that the gamma-ray emission is at most polarized at a level lower than some popular models have predicted; although our results also show intrapulse evolution of the polarization angle. This indicates that the low polarization degrees could be due to an evolving polarization angle during a gamma-ray burst.

astro-ph.HE

In-flight energy calibration of the space-borne Compton polarimeter POLAR

POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.

physics.ins-det

In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements

POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the Chinese space laboratory TG-2 on 15th September, 2016. In order to reliably reconstruct the polarization information a highly detailed understanding of the instrument is required for both data analysis and Monte Carlo studies. For this purpose a full study of the in-orbit performance was performed in order to obtain the instrument calibration parameters such as noise, pedestal, gain nonlinearity of the electronics, threshold, crosstalk and gain, as well as the effect of temperature on the above parameters. Furthermore the relationship between gain and high voltage of the multi-anode photomultiplier tube has been studied and the errors on all measurement values are presented. Finally the typical systematic error on polarization measurements of Gamma-Ray Bursts due to the measurement error of the calibration parameters are estimated using Monte Carlo simulations.

astro-ph.IM

Polarimetry with POLAR

In the first half year of operation the satellite borne POLAR instrument detected a total of 55 Gamma-Ray Bursts about 10 of which were bright enough to allow for detailed polarization studies, thereby forming the start of the first Gamma-Ray Burst polarization catalog. In this paper a brief overview of the previous GRB polarization studies will be presented followed by an overview of the POLAR detector along with the first result of the in-flight performance. The detected Gamma-Ray bursts will be presented and finally prospects for polarization measurements of these events will be discussed.

astro-ph.IM

Optimising a balloon-borne polarimeter in the hard X-ray domain: from the PoGOLite Pathfinder to PoGO+

PoGOLite is a balloon-borne hard X-ray polarimeter dedicated to the study of point sources. Compton scattered events are registered using an array of plastic scintillator units to determine the polarisation of incident X-rays in the energy range 20 - 240 keV. In 2013, a near circumpolar balloon flight of 14 days duration was completed after launch from Esrange, Sweden, resulting in a measurement of the linear polarisation of the Crab emission. Building on the experience gained from this Pathfinder flight, the polarimeter is being modified to improve performance for a second flight in 2016. Such optimisations, based on Geant4 Monte Carlo simulations, take into account the source characteristics, the instrument response and the background environment which is dominated by atmospheric neutrons. This paper describes the optimisation of the polarimeter and details the associated increase in performance. The resulting design, PoGO+, is expected to improve the Minimum Detectable Polarisation (MDP) for the Crab from 19.8% to 11.1% for a 5 day flight. Assuming the same Crab polarisation fraction as measured during the 2013 flight, this improvement in MDP will allow a 5σ constrained result. It will also allow the study of the nebula emission only (Crab off-pulse) and Cygnus X-1 if in the hard state.

astro-ph.IM

PoGOLino: a scintillator-based balloon-borne neutron detector

PoGOLino is a balloon-borne scintillator-based experiment developed to study the largely unexplored high altitude neutron environment at high geomagnetic latitudes. The instrument comprises two detectors that make use of LiCAF, a novel neutron sensitive scintillator, sandwiched by BGO crystals for background reduction. The experiment was launched on March 20th 2013 from the Esrange Space Centre, Northern Sweden (geomagnetic latitude of $65^\circ$), for a three hour flight during which the instrument took data up to an altitude of 30.9 km. The detector design and ground calibration results are presented together with the measurement results from the balloon flight.

astro-ph.IM

A Model of the Cosmic Ray Induced Atmospheric Neutron Environment

In order to optimise the design of space instruments making use of detection materials with low atomic numbers, an understanding of the atmospheric neutron environment and its dependencies on time and position is needed. To produce a simple equation based model, Monte Carlo simulations were performed to obtain the atmospheric neutron fluxes produced by charged galactic cosmic ray interactions with the atmosphere. Based on the simulation results the omnidirectional neutron environment was parametrised including dependencies on altitude, magnetic latitude and solar activity. The upward- and downward-moving component of the atmospheric neutron flux are considered separately. The energy spectra calculated using these equations were found to be in good agreement with data from a purpose built balloon-borne neutron detector, high altitude aircraft data and previously published simulation based spectra.

astro-ph.IM

A Balloon-borne Measurement of High Latitude Atmospheric Neutrons Using a LiCAF Neutron Detector

PoGOLino is a scintillator-based neutron detector. Its main purpose is to provide data on the neutron flux in the upper stratosphere at high latitudes at thermal and nonthermal energies for the PoGOLite instrument. PoGOLite is a balloon borne hard X-ray polarimeter for which the main source of background stems from high energy neutrons. No measurements of the neutron environment for the planned flight latitude and altitude exist. Furthermore this neutron environment changes with altitude, latitude and solar activity, three variables that will vary throughout the PoGOLite flight. PoGOLino was developed to study the neutron environment and the influences from these three variables upon it. PoGOLino consists of two Europium doped Lithium Calcium Aluminium Fluoride (Eu:LiCAF) scintillators, each of which is sandwiched between 2 Bismuth Germanium Oxide (BGO) scintillating crystals, which serve to veto signals produced by gamma-rays and charged particles. This allows the neutron flux to be measured even in high radiation environments. Measurements of neutrons in two separate energy bands are achieved by placing one LiCAF detector inside a moderating polyethylene shield while the second detector remains unshielded. The PoGOLino instrument was launched on March 20th 2013 from the Esrange Space Center in Northern Sweden to an altitude of 30.9 km. A description of the detector design and read-out system is presented. A detailed set of simulations of the atmospheric neutron environment performed using both PLANETOCOSMICS and Geant4 will also be described. The comparison of the neutron flux measured during flight to predictions based on these simulations will be presented and the consequences for the PoGOLite background will be discussed.

astro-ph.IM

Balloon-borne hard X-ray polarimetry with PoGOLite

PoGOLite is a hard X-ray polarimeter operating in the 25-100 keV energy band. The instrument design is optimised for the observation of compact astrophysical sources. Observations are conducted from a stabilised stratospheric balloon platform at an altitude of approximately 40 km. The primary targets for first balloon flights of a reduced effective area instrument are the Crab and Cygnus-X1. The polarisation of incoming photons is determined using coincident Compton scattering and photo-absorption events reconstructed in an array of plastic scintillator detector cells surrounded by a bismuth germanate oxide (BGO) side anticoincidence shield and a polyethylene neutron shield. A custom attitude control system keeps the polarimeter field-of-view aligned to targets of interest, compensating for sidereal motion and perturbations such as torsional forces in the balloon rigging. An overview of the PoGOLite project is presented and the outcome of the ill-fated maiden balloon flight is discussed.

astro-ph.IM