SearcharxivSearch

arXiv subjects

Merry Mani

Publications and source records attributed to Merry Mani.

7 recordsLinked to original sources

Regularized joint reconstruction and slab combination for accelerated three-dimensional multi-slab diffusion-weighted imaging using multi-scale energy models

This work presents Energy-based Profile Encoding, EPEN, a joint reconstruction framework for high-resolution diffusion-weighted MRI from undersampled 3D multi-slab k-space acquisitions, designed to suppress slab-boundary artifacts while preserving fine anatomical detail. EPEN formulates the multi-slab acquisition process using a bilinear forward model in which both the diffusion-weighted image volume and slab excitation profiles are treated as unknown variables. Reconstruction is posed as a maximum a posteriori optimization problem with three components: a Gaussian data-fidelity term enforcing consistency with the acquired k-space measurements, a CNN-based deep energy prior that represents the negative log distribution of clean diffusion-weighted images, and a quadratic regularization term that constrains the estimated slab profiles toward an initial profile estimate. The gradient of the learned energy prior guides accelerated reconstruction toward an artifact-free image distribution. The resulting nonconvex objective is solved using alternating minimization, with image-volume updates performed through a majorize-minimize scheme using conjugate-gradient optimization and slab-profile updates estimated by regularized least squares. Across multiple acceleration factors and slab configurations, EPEN substantially reduced slab-boundary artifacts compared with conventional slab-boundary correction methods, while improving structural consistency and preserving diffusion-weighted contrast. These results demonstrate that EPEN enables robust joint 3D multi-slab diffusion MRI reconstruction and slab-profile correction within a unified optimization framework supported by deep energy-based image priors.

eess.IV

Three-Dimensional Diffusion-Weighted Multi-Slab MRI With Slice Profile Compensation Using Deep Energy Model

Three-dimensional (3D) multi-slab acquisition is a technique frequently employed in high-resolution diffusion-weighted MRI in order to achieve the best signal-to-noise ratio (SNR) efficiency. However, this technique is limited by slab boundary artifacts that cause intensity fluctuations and aliasing between slabs which reduces the accuracy of anatomical imaging. Addressing this issue is crucial for advancing diffusion MRI quality and making high-resolution imaging more feasible for clinical and research applications. In this work, we propose a regularized slab profile encoding (PEN) method within a Plug-and-Play ADMM framework, incorporating multi-scale energy (MuSE) regularization to effectively improve the slab combined reconstruction. Experimental results demonstrate that the proposed method significantly improves image quality compared to non-regularized and TV-regularized PEN approaches. The regularized PEN framework provides a more robust and efficient solution for high-resolution 3D diffusion MRI, potentially enabling clearer, more reliable anatomical imaging across various applications.

eess.IV

Improved Reconstruction for high-resolution Multi-shot Diffusion Weighted Imaging

Purpose: To introduce a fast and improved direct reconstruction method for multi-shot diffusion weighted (msDW) scans for high-resolution studies. Methods:Multi-shot EPI methods can enable higher spatial resolution for diffusion MRI studies. Traditionally, such acquisitions required specialized reconstructions involving phase compensation to correct for inter-shot motion artifacts. The recently proposed MUSSELS reconstruction belongs to a new class of parallel imaging-based methods that recover artifact-free DWIs from msDW data without needing phase compensation. However, computational demands of the MUSSELS reconstruction scales as the matrix size and the number of shots increases, which hinders its practical utility for high-resolution applications. In this work, we propose a computationally efficient formulation using iterative reweighted least squares (IRLS) method. The new formulation is not only fast but it enables to accommodate additional priors such as conjugate symmetry property of the k-space data to improve the reconstruction. Using whole-brain in-vivo data, we show the utility of the new formulation for routine high-resolution studies with minimal computational burden. Results: The IRLS formulation provides about six times faster reconstruction for matrix sizes 192x192 and 256x256, compared to the original implementations. The reconstruction quality is improved by the addition of conjugate symmetry priors that reduce blurring and preserves the high-resolution details from partial Fourier acquisitions. Conclusion: The proposed method is shown to be computationally efficient to enable routine high-resolution studies. The computational complexity matches the traditional msDWI reconstruction methods and provides improved reconstruction results.

physics.med-ph

SMS MUSSELS: A Navigator-free Reconstruction for Simultaneous MultiSlice Accelerated MultiShot Diffusion Weighted Imaging

Purpose: To introduce a novel reconstruction method for simultaneous multi-slice (SMS) accelerated multi shot diffusion weighted imaging (ms-DWI). Methods: SMS acceleration using blipped CAIPI schemes have been proposed to speed up the acquisition of ms-DWIs. The reconstruction of the above data requires (i) phase compensation to combine data from different shots and (ii) slice unfolding to separate the data of different slices. The traditional approach is to first estimate the phase maps corresponding to each shot from a navigator or from the slice-aliased individual shot data. The phase maps are subsequently fed to a iterative reconstruction scheme to recover the slice unfolded DWIs. We propose a novel reconstruction method to jointly recover the slice-unfolded k-space data of the multiple shots. The proposed reconstruction is enabled by the low-rank property inherent in the k-space samples of a ms-DW acquisition. Specifically, we recover the missing samples of the multi-shot acquisition by enforcing a low-rank penalty on the block-Hankel matrix formed by the k-space data of each shot for each slice. The joint recovery of the slice-unfolded k-space data is then performed using a SENSE-based slice-unfolding subject to the low-rank constraint. The proposed joint recovery scheme is tested on simulated and in-vivo data and compared to similar un-navigated methods at slice acceleration factors of 2 and 3. Results: Our experiments show effective slice unaliasing and successful recovery of DWIs with minimal phase artifacts using the proposed method. The performance is comparable to existing methods at low acceleration factors and better than existing methods as the acceleration factor increase. Conclusion: For the slice acceleration factors considered in this study, the proposed method can successfully recover DWIs from SMS-accelerated ms-DWI acquisitions.

physics.med-ph

Calibration-free B0 correction of EPI data using structured low rank matrix recovery

We introduce a structured low rank algorithm for the calibration-free compensation of field inhomogeneity artifacts in Echo Planar Imaging (EPI) MRI data. We acquire the data using two EPI readouts that differ in echo-time (TE). Using time segmentation, we reformulate the field inhomogeneity compensation problem as the recovery of an image time series from highly undersampled Fourier measurements. The temporal profile at each pixel is modeled as a single exponential, which is exploited to fill in the missing entries. We show that the exponential behavior at each pixel, along with the spatial smoothness of the exponential parameters, can be exploited to derive a 3D annihilation relation in the Fourier domain. This relation translates to a low rank property on a structured multi-fold Toeplitz matrix, whose entries correspond to the measured k-space samples. We introduce a fast two-step algorithm for the completion of the Toeplitz matrix from the available samples. In the first step, we estimate the null space vectors of the Toeplitz matrix using only its fully sampled rows. The null space is then used to estimate the signal subspace, which facilitates the efficient recovery of the time series of images. We finally demonstrate the proposed approach on spherical MR phantom data and human data and show that the artifacts are significantly reduced. The proposed approach could potentially be used to compensate for time varying field map variations in dynamic applications such as functional MRI.

cs.CV

A General Algorithm For Compensation Of Trajectory Errors: Application To Radial Imaging

Purpose: To reconstruct artifact-free images from measured k-space data, when the actual k-space trajectory deviates from the nominal trajectory due to gradient imperfections. Methods: Trajectory errors arising from eddy currents and gradient delays introduce phase inconsistencies in several fast scanning MR pulse sequences, resulting in image artifacts. The proposed algorithm provides a novel framework to compensate for this phase distortion. The algorithm relies on the construction of a multi-block Hankel matrix, where each block is constructed from k-space segments with the same phase distortion. In the presence of spatially smooth phase distortions between the segments, the complete block-Hankel matrix is known to be highly low-rank. Since each k-space segment is only acquiring part of the k-space data, the reconstruction of the phase compensated image from their partially parallel measurements is posed as a structured low-rank matrix optimization problem, assuming the coil sensitivities to be known. Results: The proposed formulation is tested on radial acquisitions in several settings including partial Fourier and golden-angle acquisitions. The experiments demonstrate the ability of the algorithm to successfully remove the artifacts arising from the trajectory errors, without the need for trajectory or phase calibration. The quality of the reconstruction was comparable to corrections achieved using the Trajectory Auto-Corrected Image Reconstruction (TrACR) for radial acquisitions. Conclusion: The proposed method provides a general framework for the recovery of artifact-free images from radial trajectories without the need for trajectory calibration.

physics.med-ph

Multi-shot multi-channel diffusion data recovery using structured low-rank matrix completion

Purpose: To introduce a novel method for the recovery of multi-shot diffusion weighted (MS-DW) images from echo-planar imaging (EPI) acquisitions. Methods: Current EPI-based MS-DW reconstruction methods rely on the explicit estimation of the motion- induced phase maps to recover the unaliased images. In the new formulation, the k-space data of the unaliased DWI is recovered using a structured low-rank matrix completion scheme, which does not require explicit estimation of the phase maps. The structured matrix is obtained as the lifting of the multi-shot data. The smooth phase-modulations between shots manifest as null-space vectors of this matrix, which implies that the structured matrix is low-rank. The missing entries of the structured matrix are filled in using a nuclear-norm minimization algorithm subject to the data-consistency. The formulation enables the natural introduction of smoothness regularization, thus enabling implicit motion-compensated recovery of fully-sampled as well as under-sampled MS-DW data. Results: Our experiments on in-vivo data show effective removal of the ghosting artifacts arising from intershot motion in MS-DW data using the proposed method. The performance is comparable and better in certain cases than conventional phase-based methods. Conclusion: The proposed method can achieve effective unaliasing of fully/under-sampled MS-DW images without using explicit phase estimates.

physics.med-ph