Searcharxiv⌕ Search

arXiv subjects

Michał Silarski

Publications and source records attributed to Michał Silarski.

14 recordsLinked to original sources

Pulse-shape discrimination with machine learning for CZT detectors at the DA$Φ$NE beam test facility

Cadmium zinc telluride (CZT) detectors offer versatility, operational simplicity, and room-temperature X- and gamma-ray spectroscopy, making them attractive for collider applications, yet their use under high-flux conditions remains limited. Here, we present a preliminary feature-based pulse-shape analysis employing machine learning, on data acquired with a quasi-hemispherical CZT detector at the DA$\Φ$NE beam test facility of the National Laboratory of Frascati of INFN. A 300-MeV electron beam impinging on a lead target produced characteristic Pb X-rays together with a broad background extending up to the electron-positron annihilation region. Physically motivated temporal and morphological features were extracted from the recorded waveforms and used to distinguish nominal photon-like pulses from anomalous events. An XGBoost classifier trained and validated on 10,000 labeled waveforms achieved an accuracy of approximately 97%, with most of its classification performance reached using only a few hundred labeled examples. The trained model was applied to more than 700,000 events, substantially reducing the spectral continuum and coincidence peaks, while preserving the characteristic Pb X-ray lines up to the 511-keV annihilation peak. These preliminary results demonstrate the potential of machine-learning-assisted pulse-shape discrimination for improving CZT spectroscopy in collider environments.

physics.ins-det↗

First measurement of kaonic deuterium X-ray transitions

The study of the strong interaction among hadrons at low energies remains one of the key challenges in fundamental physics because of its non-perturbative nature, which makes theoretical descriptions strongly dependent on experimental input. Although substantial progress has been made for systems involving up and down quarks, theoretical models in the strangeness sector continue to face limitations due to the lack of experimental data. Kaonic atoms provide a powerful tool to study the low-energy strong interaction with strangeness through the energy shifts and widths induced on their lowest atomic levels. In this context, kaonic deuterium X-ray spectroscopy has long represented one of the major open challenges in hadronic-atom physics because of its extremely low X-ray yield. This measurement is particularly important because it gives access to the experimentally inaccessible $K^-n$ interaction at threshold energy. Here, we report the first observation of kaonic deuterium X-ray transitions, performed with the SIDDHARTA-2 experiment at the DA$Φ$NE collider. We determine the strong-interaction shift and width of the $1s$ level to be $\varepsilon_{1s}=-810.9\pm24.5\,(\mathrm{stat})\pm2.1\,(\mathrm{syst})\,\mathrm{eV}$ and $Γ_{1s}=812\pm97\,(\mathrm{stat})\pm33\,(\mathrm{syst})\,\mathrm{eV}$, respectively. This measurement constitutes the most precise experimental determination of the $K^-d$ strong interaction at threshold and allows discrimination among competing theoretical models. Combined with the kaonic hydrogen measurement, this result provides the experimental input required to determine the isospin-dependent $K^-N$ scattering lengths, with implications for the description of the nature of the first predicted hadronic molecular state, the $Λ(1405)$, and neutron-rich matter.

nucl-ex↗

Probing Nuclear Structure with Kaonic Atoms through E2 Resonance Mixing

Kaonic atoms provide a unique laboratory to investigate the interplay between atomic, nuclear, and strong-interaction physics. In heavy nuclei, atomic transitions can couple to low-lying collective nuclear excitations via the electric quadrupole interaction. When the energy difference between two kaonic atomic levels approaches that of a nuclear $2^+$ excitation, a resonant configuration mixing may occur, known as the E2 nuclear resonance effect. In this work, we investigate the conditions for E2 resonance in kaonic molybdenum isotopes. We describe the mixing using state-of-the-art Dirac-Fock calculations combined with updated nuclear structure inputs, including recent electric quadrupole transition strength values and excitation energies. We evaluate the sensitivity of the effect to key parameters, assess its observability in future experiments such as the EXKALIBUR program, and discuss its impact on cascade dynamics. Our results demonstrate the potential of kaonic atoms as a probe of nuclear structure, complementary to conventional nuclear spectroscopy.

nucl-ex↗

Extended X-ray energy characterization of SIDDHARTA-2 large-area Silicon Drift Detectors up to 50 keV

The SIDDHARTA-2 experiment at the DA$Φ$NE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction in the low-energy (O(10 keV)) regime. A large area Silicon Drift Detectors (SDDs) system has been developed to carry out these measurements. The collaboration aims to extend the measurements campaign to higher mass kaonic atoms, which exhibit transition lines at increased X-ray energies. In this context, the spectroscopic response of the SIDDHARTA-2 SDD system was investigated in terms of linearity and energy resolution up to 50 keV. An accuracy of the energy calibration procedure $ΔE/E < 10^{-3}$ was achieved.

physics.ins-det↗

EXKALIBUR: Towards a Kaonic Atoms Periodic Table to test Fundamental Interactions

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a unique laboratory to test fundamental interactions at low energies. EXKALIBUR (EXtensive Kaonic Atoms research: from LIthium and Beryllium to URanium) is a program to perform systematic, high-precision X-ray spectroscopy of selected kaonic atoms across the periodic table at the DA$Φ$NE accelerator at the National Laboratory of Frascati (INFN-LNF). Here, we outline its detector-driven strategy: Silicon Drift Detectors for 10-40 keV transitions in light targets (Li, Be, B, O), CdZnTe detectors for 40-300 keV lines in intermediate-$Z$ systems (Mg, Al, Si, S), and a High-Purity Germanium detector for high-$Z$ atoms (Se, Zr, Ta, Mo, W, Pb), complemented by VOXES, a high-resolution crystal spectrometer for sub-eV studies. EXKALIBUR plans to (i) reduce the charged-kaon mass uncertainty below 10 keV, (ii) produce a database of nuclear shifts and widths to constrain multi-nucleon K$^{-}$-nucleus interaction models, and (iii) provide precision data for testing bound-state QED in strong fields. We summarize the planned measurements and expected sensitivities within DA$Φ$NE luminosities.

nucl-ex↗

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph↗

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph↗

First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c

We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.

nucl-ex↗

Positronium imaging with the novel multiphoton PET scanner

In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.

physics.med-ph↗

Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.

nucl-ex↗

Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider

A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high precision light kaonic atoms spectroscopy measurements in the high background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the kaonic helium first exotic atoms run of SIDDHARTA-2, preliminary to the kaonic deuterium data taking campaign

physics.ins-det↗

Estimating the NEMA characteristics of the J-PET tomograph using the GATE package

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were performed. The spatial resolution, the sensitivity, the scatter fraction and the noise equivalent count rate were estimated according to the NEMA norm as a function of the length of the tomograph, number of the detection layers, diameter of the tomographic chamber and for various types of the applied readout. For the single-layer geometry with the diameter of 85 cm, strip length of 100 cm, cross-section of 4 mm x 20 mm and silicon photomultipliers with the additional layer of wavelength shifter as the readout, the spatial resolution (FWHM) in the centre of the scanner is equal to 3 mm (radial, tangential) and 6 mm (axial). For the analogous double-layer geometry with the same readout, diameter and scintillator length, with the strip cross-section of 7 mm x 20 mm, the NECR peak of 300 kcps was reached at 40 kBq/cc activity concentration, the scatter fraction is estimated to about 35% and the sensitivity at the centre amounts to 14.9 cps/kBq. Sensitivity profiles were also determined.

physics.ins-det↗

3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to the measurement. The problem is how to turn this measurement into an image (this is called imaging). Decisive improvement in PET image quality was reached with the introduction of iterative reconstruction techniques. This stage was reached already twenty years ago (with the advent of new powerful computing processors). However, three dimensional (3D) imaging remains still a challenge. The purpose of the image reconstruction algorithm is to process this imperfect count data for a large number (many millions) of lines-of-responce (LOR) and millions of detected photons to produce an image showing the distribution of the labeled molecules in space.

physics.med-ph↗