SearcharxivSearch

arXiv subjects

Michał Zawada

Publications and source records attributed to Michał Zawada.

8 recordsLinked to original sources

Isotopic effect on collisional widths and shifts of Hg clock transition induced by cold Rb atoms

We study the isotopic dependence of collisional widths and shifts of the Hg clock transition $^1$S$_0$-$^3$P$_0$ perturbed by the Rb atoms in the temperature range from 1 nK to 1 K. For this purpose, we model the Born-Oppenheimer effective interaction potential by including the leading long-range van der Waals coefficients. For elastic collisions, we show the connection between the dependence of collision line shape parameters on the reduced mass of colliding partners as well as the variation of the scattering length in the excited and ground states of the Hg-Rb system in the $\upmu$K temperature range. We confront the full quantum scattering calculations with a semi-classical approximation for collisional widths and shifts. We show that the shape resonances in excited and ground scattering states lead to significant variations of collisional line shape parameters with the change of the reduced mass of colliding atoms. We also indicate the possible influence of inelastic collisions, which could lead to universal behavior and significantly affect the dependence of collisional broadening and shifting on the isotopic combination of colliding atoms.

physics.atom-ph

Mechanical loss and stability analysis of NEXCERA in ultra-stable optical cavities

NEXCERA has emerged as a ceramic-based material for spacers in ultra-stable optical cavities, with a coefficient of thermal expansion that crosses zero near room temperature. In such cavities, frequency stability is ultimately limited by Brownian thermal noise in the cavity components. A key parameter in this context is the mechanical loss, which has remained unknown for NEXCERA. In this work, we investigate the mechanical loss of NEXCERA N117B at room temperature for various resonances using the gentle nodal suspension technique. We measure a promising minimum mechanical loss of $ϕ= 1.89\times 10^{-5}$, indicating the suitability of NEXCERA for low-noise optical cavities. Using this value, we calculate the thermal noise of a cavity with a NEXCERA spacer and compare its performance to established materials such as ULE and Zerodur, taking into account different mirror substrate options. Our analysis shows that NEXCERA is a strong candidate for ultra-stable cavities due to its low thermal noise. Combined with its previously reported low linear drift, it offers a highly attractive option for long-term stable optical frequency references.

physics.optics

Guidelines for designs for ultrastable laser with $\mathbf{10^{-17}}$ fractional frequency instability

Lasers with long coherence time and narrow linewidth are an essential tool for quantum sensors and clocks. Ultrastable cavities and laser systems are now commercially available with fractional frequency instabilities in the mid $10^{-16}$ range. This document aims to provide technical guidance for researchers starting in the field of ultrastable lasers and to give an outlook toward the next generation of improved ultrastable lasers. These guidelines have arisen from the scope of the EMPIR project ``Next generation ultrastable lasers'' ( https://www.ptb.de/empir2021/nextlasers ) with contributions from the European project partners.

physics.optics

Engineering the sensitivity of macroscopic physical systems to variations in the fine-structure constant

Experiments aimed at searching for variations in the fine-structure constant $α$ are based on spectroscopy of transitions in microscopic bound systems, such as atoms and ions, or resonances in optical cavities. The sensitivities of these systems to variations in $α$ are typically on the order of unity and are fixed for a given system. For heavy atoms, highly charged ions and nuclear transitions, the sensitivity can be increased by benefiting from the relativistic effects and favorable arrangement of quantum states. This article proposes a new method for controlling the sensitivity factor of macroscopic physical systems. Specific concepts of optical cavities with tunable sensitivity to $α$ are described. These systems show qualitatively different properties from those of previous studies of the sensitivity of macroscopic systems to variations in $α$, in which the sensitivity was found to be fixed and fundamentally limited to an order of unity. Although possible experimental constraints attainable with the specific optical cavity arrangements proposed in this article do not yet exceed the present best constraints on $α$ variations, this work paves the way for developing new approaches to searching for variations in the fundamental constants of physics.

physics.atom-ph

Ultimate stability of active optical frequency standards

Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usable levels with the current state of technology. Here we investigate the spectral properties and the stability of active clocks, including homogeneous and inhomogeneous broadening effects. We find that for short averaging times the stability is limited by photon shot noise from the limited emitted laser power and at long averaging times by phase diffusion of the laser output. Operational parameters for best long-term stability were identified. Using realistic numbers for an active clock with $^{87}$Sr we find that an optimized stability of $σ_y(τ) \approx 4\times10^{-18}/\sqrt{τ[\mathrm{s}]}$ is achievable.

physics.atom-ph

Photoionization cross sections of ultracold $^{88}$Sr in $^1$P$_1$ and $^3$S$_1$ states at 390 nm and the resulting blue-detuned magic wavelength optical lattice clock constraints

We present the measurements of the photoionisation cross sections of the excited $^1$P$_1$ and $^3$S$_1$ states of ultracold $^{88}$Sr atoms at 389.889 nm wavelength, which is the magic wavelength of the $^{1}$S$_{0}$-${}^{3}$P${}_{0}$ clock transition. The photoionisation cross section of the $^1$P$_1$ state is determined from the measured ionisation rates of $^{88}$Sr in the magneto-optical trap in the $^1$P$_1$ state to be 2.20(50)$\times$10$^{-20}$ m$^2$, while the photoionisation cross section of $^{88}$Sr in the $^3$S$_1$ state is inferred from the photoionisation-induced reduction in the number of atoms transferred through the $^3\text{S}_1$ state in an operating optical lattice clock to be $1.38(66)\times$10$^{-18}$ m$^2$. Furthermore, the resulting limitations of employing a blue-detuned magic wavelength optical lattice in strontium optical lattice clocks are evaluated. We estimated photoionisation induced loss rates of atoms at 389.889 nm wavelength under typical experimental conditions and made several suggestions on how to mitigate these losses. In particular, the large photoionisation induced losses for the $^3$S$_1$ state would make the use of the $^3$S$_1$ state in the optical cycle in a blue-detuned optical lattice unfeasible and would instead require the less commonly used $^3$D$_{1,2}$ states during the detection part of the optical clock cycle.

physics.atom-ph

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph

Probe spectroscopy in an operating magneto-optical trap: the role of Raman transitions between discrete and continuum atomic states

We report on cw measurements of probe beam absorption and four-wave-mixing spectra in a $^{85}$Rb magneto-optical trap taken while the trap is in operation. The trapping beams are used as pump light. We concentrate on the central feature of the spectra at small pump-probe detuning and attribute its narrow resonant structures to the superposition of Raman transitions between light-shifted sublevels of the ground atomic state and to atomic recoil processes. These two contributions have different dependencies on trap parameters and we show that the former is inhomogeneously broadened. The strong dependence of the spectra on the probe-beam polarization indicates the existence of large optical anisotropy of the cold-atom sample, which is attributed to the recoil effects. We point out that the recoil-induced resonances can be isolated from other contributions, making pump-probe spectroscopy a highly sensitive diagnostic tool for atoms in a working MOT.

physics.atom-ph