SearcharxivSearch

arXiv subjects

Michael Bach

Publications and source records attributed to Michael Bach.

7 recordsLinked to original sources

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

cs.AI

A Multi-Centric Anthropomorphic 3D CT Phantom-Based Benchmark Dataset for Harmonization

Artificial intelligence (AI) has introduced numerous opportunities for human assistance and task automation in medicine. However, it suffers from poor generalization in the presence of shifts in the data distribution. In the context of AI-based computed tomography (CT) analysis, significant data distribution shifts can be caused by changes in scanner manufacturer, reconstruction technique or dose. AI harmonization techniques can address this problem by reducing distribution shifts caused by various acquisition settings. This paper presents an open-source benchmark dataset containing CT scans of an anthropomorphic phantom acquired with various scanners and settings, which purpose is to foster the development of AI harmonization techniques. Using a phantom allows fixing variations attributed to inter- and intra-patient variations. The dataset includes 1378 image series acquired with 13 scanners from 4 manufacturers across 8 institutions using a harmonized protocol as well as several acquisition doses. Additionally, we present a methodology, baseline results and open-source code to assess image- and feature-level stability and liver tissue classification, promoting the development of AI harmonization strategies.

cs.CV

Clinnova Federated Learning Proof of Concept: Key Takeaways from a Cross-border Collaboration

Clinnova, a collaborative initiative involving France, Germany, Switzerland, and Luxembourg, is dedicated to unlocking the power of precision medicine through data federation, standardization, and interoperability. This European Greater Region initiative seeks to create an interoperable European standard using artificial intelligence (AI) and data science to enhance healthcare outcomes and efficiency. Key components include multidisciplinary research centers, a federated biobanking strategy, a digital health innovation platform, and a federated AI strategy. It targets inflammatory bowel disease, rheumatoid diseases, and multiple sclerosis (MS), emphasizing data quality to develop AI algorithms for personalized treatment and translational research. The IHU Strasbourg (Institute of Minimal-invasive Surgery) has the lead in this initiative to develop the federated learning (FL) proof of concept (POC) that will serve as a foundation for advancing AI in healthcare. At its core, Clinnova-MS aims to enhance MS patient care by using FL to develop more accurate models that detect disease progression, guide interventions, and validate digital biomarkers across multiple sites. This technical report presents insights and key takeaways from the first cross-border federated POC on MS segmentation of MRI images within the Clinnova framework. While our work marks a significant milestone in advancing MS segmentation through cross-border collaboration, it also underscores the importance of addressing technical, logistical, and ethical considerations to realize the full potential of FL in healthcare settings.

cs.CV

Multi-centric AI Model for Unruptured Intracranial Aneurysm Detection and Volumetric Segmentation in 3D TOF-MRI

Purpose: To develop an open-source nnU-Net-based AI model for combined detection and segmentation of unruptured intracranial aneurysms (UICA) in 3D TOF-MRI, and compare models trained on datasets with aneurysm-like differential diagnoses. Methods: This retrospective study (2020-2023) included 385 anonymized 3D TOF-MRI images from 364 patients (mean age 59 years, 60% female) at multiple centers plus 113 subjects from the ADAM challenge. Images featured untreated or possible UICAs and differential diagnoses. Four distinct training datasets were created, and the nnU-Net framework was used for model development. Performance was assessed on a separate test set using sensitivity and False Positive (FP)/case rate for detection, and DICE score and NSD (Normalized Surface Distance) with a 0.5mm threshold for segmentation. Statistical analysis included chi-square, Mann-Whitney-U, and Kruskal-Wallis tests, with significance set at p < 0.05. Results: Models achieved overall sensitivity between 82% and 85% and a FP/case rate of 0.20 to 0.31, with no significant differences (p = 0.90 and p = 0.16). The primary model showed 85% sensitivity and 0.23 FP/case rate, outperforming the ADAM-challenge winner (61%) and a nnU-Net trained on ADAM data (51%) in sensitivity (p < 0.05). It achieved a mean DICE score of 0.73 and an NSD of 0.84 for correctly detected UICA. Conclusions: Our open-source, nnU-Net-based AI model (available at 10.5281/zenodo.13386859) demonstrates high sensitivity, low false positive rates, and consistent segmentation accuracy for UICA detection and segmentation in 3D TOF-MRI, suggesting its potential to improve clinical diagnosis and for monitoring of UICA.

cs.CV

Assessing radiomics feature stability with simulated CT acquisitions

Medical imaging quantitative features had once disputable usefulness in clinical studies. Nowadays, advancements in analysis techniques, for instance through machine learning, have enabled quantitative features to be progressively useful in diagnosis and research. Tissue characterisation is improved via the 'radiomics' features, whose extraction can be automated. Despite the advances, stability of quantitative features remains an important open problem. As features can be highly sensitive to variations of acquisition details, it is not trivial to quantify stability and efficiently select stable features. In this work, we develop and validate a Computed Tomography (CT) simulator environment based on the publicly available ASTRA toolbox (www.astra-toolbox.com). We show that the variability, stability and discriminative power of the radiomics features extracted from the virtual phantom images generated by the simulator are similar to those observed in a tandem phantom study. Additionally, we show that the variability is matched between a multi-center phantom study and simulated results. Consequently, we demonstrate that the simulator can be utilised to assess radiomics features' stability and discriminative power.

physics.comp-ph

TotalSegmentator: robust segmentation of 104 anatomical structures in CT images

We present a deep learning segmentation model that can automatically and robustly segment all major anatomical structures in body CT images. In this retrospective study, 1204 CT examinations (from the years 2012, 2016, and 2020) were used to segment 104 anatomical structures (27 organs, 59 bones, 10 muscles, 8 vessels) relevant for use cases such as organ volumetry, disease characterization, and surgical or radiotherapy planning. The CT images were randomly sampled from routine clinical studies and thus represent a real-world dataset (different ages, pathologies, scanners, body parts, sequences, and sites). The authors trained an nnU-Net segmentation algorithm on this dataset and calculated Dice similarity coefficients (Dice) to evaluate the model's performance. The trained algorithm was applied to a second dataset of 4004 whole-body CT examinations to investigate age dependent volume and attenuation changes. The proposed model showed a high Dice score (0.943) on the test set, which included a wide range of clinical data with major pathologies. The model significantly outperformed another publicly available segmentation model on a separate dataset (Dice score, 0.932 versus 0.871, respectively). The aging study demonstrated significant correlations between age and volume and mean attenuation for a variety of organ groups (e.g., age and aortic volume; age and mean attenuation of the autochthonous dorsal musculature). The developed model enables robust and accurate segmentation of 104 anatomical structures. The annotated dataset (https://doi.org/10.5281/zenodo.6802613) and toolkit (https://www.github.com/wasserth/TotalSegmentator) are publicly available.

eess.IV

Historical Context, Scientific Context, and Translation of Haidinger's (1844) Discovery of Naked-Eye Visibility of the Polarization of Light

In 1844, the Austrian mineralogist Wilhelm von Haidinger reported he could see the polarization of light with the naked eye. It appears as a faint, blurry, transient, yellow hourglass shape superimposed on whatever one looks at. It is now commonly called Haidinger's brushes. To our surprise, even though the paper is well cited, we were unable to find a translation of it from its difficult, nineteenth-century German into English. We provide one, with annotations to set the paper into its scientific and historical context.

physics.hist-ph