Searcharxiv⌕ Search

arXiv subjects

Michael Caouette-Mansour

Publications and source records attributed to Michael Caouette-Mansour.

4 recordsLinked to original sources

Fabricating fiber cavity mirror substrates compatible with high coupling efficiency

Fiber optical cavities offer small mode volumes and correspondingly strong light-matter interactions in an open Fabry-Perot geometry. However, existing fabrication techniques do not reliably produce substrates with surface profiles amenable to high mode matching between the cavity mode and fiber core, thereby limiting the achievable collection efficiency. Here we present a technique to fabricate fiber mirror substrates while using $\textit{in situ}$ reflectometry to constrain the achievable mode matching prior to coating. By measuring the back-reflection from freshly cleaved fiber tips, we pre-select 138 fibers compatible with 96.5-99.5% mode matching, and after a single CO$_2$ laser ablation pulse, these fibers remained compatible with 95.3-99.2\%. This simple technique provides rapid feedback during each stage of substrate fabrication, greatly enhancing the yield of viable fiber mirror substrates prior to (expensive) coating runs.

physics.optics↗

Comparing continuous and pulsed nitrogen-vacancy DC magnetometry in the optical-power-limited regime

Ensembles of nitrogen-vacancy (NV) center spins in diamond offer a robust, precise and accurate magnetic sensor. As their applications move beyond the laboratory, practical considerations including size, complexity, and power consumption become important. Here, we compare two commonly-employed NV magnetometry techniques -- continuous-wave (CW) vs pulsed magnetic resonance -- in a scenario limited by total available optical power. We develop a consistent theoretical model for the magnetic sensitivity of each protocol that incorporates NV photophysics - in particular, including the incomplete spin polarization associated with limited optical power; after comparing the models' behaviour to experiments, we use them to predict the relative DC sensitivity of CW versus pulsed operation for an optical-power-limited, shot-noise-limited NV ensemble magnetometer. We find a $\sim 2-3 \times$ gain in sensitivity for pulsed operation, which is significantly smaller than seen in power-unlimited, single-NV experiments. Our results provide a resource for practical sensor development, informing protocol choice and identifying optimal operation regimes when optical power is constrained.

quant-ph↗

Single-spin spectroscopy of spontaneous and phase-locked spin torque oscillator dynamics

We employ N-$V$ magnetometry to measure the stray field dynamics of a ferromagnetic permalloy nanowire driven by spin-orbit torques. Specifically, we observe the optically detected magnetic resonance (ODMR) signatures of both spontaneous DC-driven magnetic oscillations and phase-locking to a second harmonic drive, developing a simple macrospin model that captures the salient features. We also observe signatures of dynamics beyond the macrospin model, including an additional ODMR feature (associated with a second SW mode) and one mode sapping power from another. Our results provide additional insight into N-$V$-spin wave coupling mechanisms, and represent a new modality for sub-wavelength N-$V$ scanned probe microscopy of nanoscale magnetic oscillators.

cond-mat.mes-hall↗

Robust spin relaxometry with fast adaptive Bayesian estimation

Spin relaxometry with nitrogen-vacancy (NV) centers in diamond offers a spectrally selective, atomically localized, and calibrated measurement of microwave-frequency magnetic noise, presenting a versatile probe for condensed matter and biological systems. Typically, relaxation rates are estimated with curve-fitting techniques that do not provide optimal sensitivity, often leading to long acquisition times that are particularly detrimental in systems prone to drift or other dynamics of interest. Here we show that adaptive Bayesian estimation is well suited to this problem, producing dynamic relaxometry pulse sequences that rapidly find an optimal operating regime. In many situations (including the system we employ), this approach can speed the acquisition by an order of magnitude. We also present a four-signal measurement protocol that is robust to drifts in spin readout contrast, polarization, and microwave pulse fidelity while still achieving near-optimal sensitivity. The combined technique offers a practical, hardware-agnostic approach for a wide range of NV relaxometry applications.

quant-ph↗