Searcharxiv⌕ Search

arXiv subjects

Michael Deimetry

Publications and source records attributed to Michael Deimetry.

4 recordsLinked to original sources

Three-dimensional dopant depth determination from momentum-resolved core-loss 4D-STEM data

Moving beyond specimen-projected micrographs in scanning transmission electron microscopy to determine a three-dimensional distribution of dopants is of vital importance for materials characterization and development. Within the Born approximation, Fourier transformation over probe position of a momentum-resolved core-loss 4D-STEM dataset reveals fringes whose frequency encodes the dopant's distance from the focal plane. We address two principal challenges which arise under experimental circumstances. First, fringe contrast is degraded by dynamical scattering, but can be partially recovered by acquiring off major zone axes. Second, the excessive doses typical of core-loss scattering can be alleviated using a Bayesian framework which, on a simulated Fe-doped strontium titanate, achieves nanometre to sub-nanometre depth precision from 100 to 1000 core-loss counts, depending on the signal-to-background.

cond-mat.mtrl-sci↗

Three-dimensional dopant distribution from a single, out-of-focus spectroscopic image

Increasing miniaturization of nanoscale devices makes determining the three-dimensional distribution of dopants increasingly important. In out-of-focus spectroscopic scanning transmission electron microscopy images, we show that dopant atoms appear as disks with radii relating to dopant depth, allowing the three-dimensional distribution of dopants to be determined from simple geometric analysis of a single out-of-focus image. Through numerical experiments on Si-doped graphene we validate statistical detection and Bayesian inference methods to quantify confidence and uncertainties while making the analysis more robust at lower dose. We present proof-of-concept experimental data from an Fe-doped spinel, retrieving dopant depth to within around 2 nanometres.

cond-mat.other↗

Dopant site occupancy determined by core-loss-filtered, position-averaged convergent beam electron diffraction

In the elastic scattering regime, probe position-averaged convergent beam electron diffraction (PACBED) patterns have proven robust for estimating specimen thickness and mistilt. Through simulation, we show that core-loss-filtered PACBED patterns can be used to measure the site occupancy of a small concentration of dopants in an otherwise known crystal structure. By leveraging the reciprocity between scanning and conventional transmission electron microscopy, we interpret core-loss PACBED patterns using a strategy traditionally used for determining dopant concentrations via energy dispersive X-ray spectroscopy. We show that differences in the interaction range of different elements hinder a purely measurement-based quantification strategy, but that this can be overcome through comparison with simulations that generalize the Cliff-Lorimer k-factors.

cond-mat.other↗

Differential phase contrast from electrons that cause inner shell ionization

Differential Phase Contrast (DPC) imaging, in which deviations in the bright field beam are in proportion to the electric field, has been extensively studied in the context of pure elastic scattering. Here we discuss differential phase contrast formed from core-loss scattered electrons, i.e. those that have caused inner shell ionization of atoms in the specimen, using a transition potential approach for which we study the number of final states needed for a converged calculation. In the phase object approximation, we show formally that differential phase contrast formed from core-loss scattered electrons is mainly a result of preservation of elastic contrast. Through simulation we demonstrate that whether the inelastic DPC images show element selective contrast depends on the spatial range of the ionization interaction, and specifically that when the energy loss is low the delocalisation can lead to contributions to the contrast from atoms other than that ionized. We further show that inelastic DPC images remain robustly interpretable to larger thicknesses than is the case for elastic DPC images, owing to the incoherence of the inelastic wavefields, though subtleties due to channelling remain. Lastly, we show that while a very high dose will be needed for sufficient counting statistics to discern differential phase contrast from core-loss scattered electrons, there is some enhancement of signal-to-noise ratio with thickness that makes inelastic DPC imaging more achievable for thicker samples.

cond-mat.other↗