SearcharxivSearch

arXiv subjects

Michael Dyck

Publications and source records attributed to Michael Dyck.

5 recordsLinked to original sources

EMG-Based Adaptation of Anisotropic Virtual Fixtures for Robot-Assisted Surgical Resection and Dissection

In this paper, we address the development of an adaptive assistance system for robot-assisted laparoscopic surgery, specifically for delicate tasks such as Resection and Dissection. Even if Virtual Fixtures offer significant advantages for guiding a surgeon's movements, conventional Virtual Fixtures are often defined by fixed geometries, lacking the flexibility to adapt to the surgical workflow or the surgeon's immediate intent. To address these limitations, we propose a novel framework for an adaptive and anisotropic virtual fixture. In addition, we introduce an intuitive control interface that modulates the fixture's geometry in real-time based on the surgeon's intent, inferred from EMG signals. This approach allows the surgeon to dynamically expand or disengage the constraint by contracting their forearm muscles, enabling seamless transitions between precise guided motion and free repositioning of the tool. Experimental results from a pilot user study, based on a standardized surgical training task, demonstrate the effectiveness of the proposed method. The system showed significant improvements in task accuracy and movement consistency, alongside a reduction in perceived cognitive load, effort, and frustration.

cs.RO

Towards Safe and Collaborative Robotic Ultrasound Tissue Scanning in Neurosurgery

Intraoperative ultrasound imaging is used to facilitate safe brain tumour resection. However, due to challenges with image interpretation and the physical scanning, this tool has yet to achieve widespread adoption in neurosurgery. In this paper, we introduce the components and workflow of a novel, versatile robotic platform for intraoperative ultrasound tissue scanning in neurosurgery. An RGB-D camera attached to the robotic arm allows for automatic object localisation with ArUco markers, and 3D surface reconstruction as a triangular mesh using the ImFusion Suite software solution. Impedance controlled guidance of the US probe along arbitrary surfaces, represented as a mesh, enables collaborative US scanning, i.e., autonomous, teleoperated and hands-on guided data acquisition. A preliminary experiment evaluates the suitability of the conceptual workflow and system components for probe landing on a custom-made soft-tissue phantom. Further assessment in future experiments will be necessary to prove the effectiveness of the presented platform.

cs.RO

Identifying visible tissue in intraoperative ultrasound: a method and application

Purpose: Intraoperative ultrasound scanning is a demanding visuotactile task. It requires operators to simultaneously localise the ultrasound perspective and manually perform slight adjustments to the pose of the probe, making sure not to apply excessive force or breaking contact with the tissue, whilst also characterising the visible tissue. Method: To analyse the probe-tissue contact, an iterative filtering and topological method is proposed to identify the underlying visible tissue, which can be used to detect acoustic shadow and construct confidence maps of perceptual salience. Results: For evaluation, datasets containing both in vivo and medical phantom data are created. A suite of evaluations is performed, including an evaluation of acoustic shadow classification. Compared to an ablation, deep learning, and statistical method, the proposed approach achieves superior classification on in vivo data, achieving an F_beta score of 0.864, in comparison to 0.838, 0.808, 0.808. A novel framework for evaluating the confidence estimation of probe tissue contact is created. The phantom data is captured specifically for this, and comparison is made against two established methods. The proposed method produced the superior response, achieving an average normalised root mean square error of 0.168, in comparison to 1.836 and 4.542. Evaluation is also extended to determine the algorithm's robustness to parameter perturbation, speckle noise, data distribution shift, and capability for guiding a robotic scan. Conclusion: The results of this comprehensive set of experiments justify the potential clinical value of the proposed algorithm, which can be used to support clinical training and robotic ultrasound automation.

eess.IV

Automated robotic intraoperative ultrasound for brain surgery

During brain tumour resection, localising cancerous tissue and delineating healthy and pathological borders is challenging, even for experienced neurosurgeons and neuroradiologists. Intraoperative imaging is commonly employed for determining and updating surgical plans in the operating room. Ultrasound (US) has presented itself a suitable tool for this task, owing to its ease of integration into the operating room and surgical procedure. However, widespread establishment of this tool has been limited because of the difficulty of anatomy localisation and data interpretation. In this work, we present a robotic framework designed and tested on a soft-tissue-mimicking brain phantom, simulating intraoperative US (iUS) scanning during brain tumour surgery.

cs.RO

Collaborative Robotic Ultrasound Tissue Scanning for Surgical Resection Guidance in Neurosurgery

The aim of this paper is to introduce a robotic platform for autonomous iUS tissue scanning to optimise intraoperative diagnosis and improve surgical resection during robot-assisted operations. To guide anatomy specific robotic scanning and generate a representation of the robot task space, fast and accurate techniques for the recovery of 3D morphological structures of the surgical cavity are developed. The prototypic DLR MIRO surgical robotic arm is used to control the applied force and the in-plane motion of the US transducer. A key application of the proposed platform is the scanning of brain tissue to guide tumour resection.

cs.RO