SearcharxivSearch

arXiv subjects

Michael Feinberg

Publications and source records attributed to Michael Feinberg.

2 recordsLinked to original sources

From Prediction to Intervention: The Evolution of AI in Biomedicine

Artificial intelligence has advanced rapidly in biomedicine through large-scale multimodal data integration, enabling increasingly accurate prediction of clinical outcomes and patient stratification. These systems, however, remain fundamentally observational: they learn statistical associations from historical data and operate within previously observed biological and clinical states, limiting their ability to generalize to novel therapies or unobserved interventions. We argue that AI in biomedicine is undergoing a structural transition. As biomedical decision-making increasingly depends on reasoning about intervention rather than extrapolation from past observations, predictive architectures become structurally insufficient. Systems that learn from historical data cannot, by construction, represent how biological systems evolve under perturbation, and therefore cannot reliably support decision-making in the presence of novel interventions. We introduce a conceptual framework distinguishing observational and interventional intelligence and define disease-level models as systems that explicitly represent the state, dynamics, and intervention response of biological processes. These models enable a shift from inference to simulation -- reasoning about what will happen under intervention rather than what is likely based on the past. This transition also implies a shift in where value is created: from data processing and prediction toward systems that support and define decision-making under intervention. It follows directly from the structure of biomedical decision-making and defines the next stage of AI in medicine. Systems that cannot model intervention will be structurally excluded from decision-making.

cs.CY

Laboratory demonstration of a cryogenic deformable mirror for wavefront correction of space-borne infrared telescopes

This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error of their mirror surface, which makes the imaging performance worse. For on-orbit wavefront correction as one solution, we developed a MEMS-processed electro-static DM with a special surrounding structure for use under the cryogenic temperature. We conducted a laboratory demonstration of its operation in three cooling cycles between 5 K and 295 K. Using a laser interferometer, we detected the deformation corresponding to the applied voltages under the cryogenic temperature for the first time. The relationship between voltages and displacements was qualitatively expressed by the quadratic function, which is assumed based on the principle of electro-static DMs. We also found that it had a high operating repeatability of a few nm RMS and no significant hysteresis. Using the measured values of repeatability, we simulated the improvement of PSF by wavefront correction with our DM. These results show that our developed DM is effective in improving imaging performance and PSF contrast of space-borne infrared telescopes.

astro-ph.IM