SearcharxivSearch

arXiv subjects

Michael G. Huber

Publications and source records attributed to Michael G. Huber.

12 recordsLinked to original sources

Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access

Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room temperature and standard atmospheric pressure. However, neutron interferometry is sensitive to changes in the local environment, especially thermal gradients across the crystal, resulting in phase drifts and systematic uncertainty. A need for measurements performed in different sample environments compound these issues. Fortunately, the use of a vacuum chamber has been shown to be an effective method of environmental isolation for perfect-crystal neutron interferometers. A large volume, highly versatile vacuum chamber has been installed at the Neutron Interferometry and Optics Facility at the NIST Center for Neutron Research to isolate interferometry from local temperature and pressure deviations as well as allowing for the introduction of cryogenically cooled samples. The prospect of incorporating a cryostat within a neutron interferometer opens up new areas of investigation, such as superconductivity. In addition to describing the vacuum chamber, we report on the first measurement of a cryogenic-cooled sample by a neutron interferometer. For this demonstration contrast was measured with a Ni60Cu40 sample between 4 K to 300 K.

physics.ins-det

A unified quantum random walk model for internal crystal effects in dynamical diffraction

The theory of dynamical diffraction (DD) in perfect crystals is the backbone of high-precision neutron and X-ray diffraction experiments, enabling accurate determination of crystal structure factors and the realization of perfect crystal interferometers. In practice, however, real crystals exhibit deformations and imperfections, including surface roughness, defects, temperature gradients, angled crystal faces, and curvature, that degrade interferometer performance and are difficult to model using conventional DD theory, particularly in complex geometries. To address these challenges, a quantum information (QI) model for DD has been under development, with demonstrated experimental agreement for both ideal crystals and in the presence of some imperfections such as surface roughness and defects. Here, we present a unified quantum random walk model that is now suitable for reproducing all established DD effects. We demonstrate this by incorporating a broad range of internal crystal effects influencing DD intensity distributions, including linear temperature gradients, the DD Talbot effect, and angled or miscut crystals. These results establish the QI model as a comprehensive and flexible framework for experimental analysis, as well as for the design of next-generation perfect crystal neutron interferometers and neutron optical components, such as condensing monochromators.

physics.app-ph

A perfect crystal neutron loop cavity

Coherent control of neutrons via Bragg diffraction forms the foundation of perfect crystal neutron interferometry, facilitating both fundamental tests of quantum mechanics and applications in quantum information science. In cavity geometries, perfect crystals enable neutron confinement and have been employed in precision measurements of spin-orbit interactions and for neutron electric dipole moment (nEDM) searches. However, in these conventional configurations, neutrons undergo a single pass through the crystal geometry, placing a physical constraint on both crystal and in-flight interaction times and measurement sensitivity. In this work, we introduce a neutron loop cavity that coherently recirculates neutrons through repeated Bragg reflections between perfect silicon crystal blades. This structure is predicted to achieve a neutron survival probability of $\sim64~\%$ for 10,000 Bragg reflections, corresponding to confinement times on the order of seconds. We propose a Schwinger interaction measurement that achieves a $π$ spin rotation in 800 Bragg reflections, representing more than a tenfold improvement in sensitivity over recent measurements. Further applications include high-sensitivity nEDM searches targeting the $10^{-27}~$e$\cdot$cm scale, as well as competitive experimental tests of neutron parity violation, the neutron lifetime, and the quantum Zeno effect with neutrons.

physics.ins-det

Multimode structured neutron beams

The experimental realization of neutron orbital angular momentum (OAM) states and neutron Airy beams has opened new avenues for structured neutron science in both materials characterization and fundamental physics. These additional degrees of freedom in scattering experiments enable the exploration of selection rules for neutrons, the analysis of scattering properties in topological materials, and the generation of auto-focusing neutron beams. In the effort to enhance the amount of spatial and angular-momentum information retrievable from a single measurement, and to overcome current phase-grating efficiency limits, here we demonstrate multimode structured neutron beams that enable simultaneous access to multiple, well-defined OAM modes, and to hybrid combinations of OAM and Airy states. This multimode approach, analogous to wavelength- or OAM-multiplexing in optics, facilitates the efficient investigation of material scattering properties and nuclear interactions with a neutron source composed of a discretized OAM spectrum.

physics.app-ph

Generation of neutron Airy beams

The Airy wave packet is a solution to the potential-free Schrodinger equation that exhibits remarkable properties such as self-acceleration, non-diffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this work, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of non-elementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams.

physics.app-ph

Small-angle scattering interferometry with neutron orbital angular momentum states

Access to the neutron orbital degree of freedom has been enabled by the recent actualization of methods to prepare and characterize neutron helical waves carrying orbital angular momentum (OAM) at small-angle neutron scattering (SANS) facilities. This provides new avenues of exploration in fundamental science experiments as well as in material characterization applications. However, it remains a challenge to recover phase profiles from SANS measurements. We introduce and demonstrate a novel neutron interferometry technique for extracting phase information that is typically lost in SANS measurements. An array of reference beams, with complementary structured phase profiles, are put into a coherent superposition with the array of object beams, thereby manifesting the phase information in the far-field intensity profile. We demonstrate this by resolving petal-structure signatures of helical wave interference for the first time: an implementation of the long-sought recovery of phase information from small-angle scattering measurements.

physics.app-ph

Pendellösung Interferometry Probes the Neutron Charge Radius, Lattice Dynamics, and Fifth Forces

Structure factors describe how incident radiation is scattered from materials such as silicon and germanium and characterize the physical interaction between the material and scattered particles. We use neutron pendellösung interferometry to make precision measurements of the (220) and (400) neutron-silicon structure factors, and achieve a factor of four improvement in the (111) structure factor uncertainty. These data provide measurements of the silicon Debye-Waller factor at room temperature and the mean square neutron charge radius $\langle r_n^2 \rangle = -0.1101 \pm 0.0089 \, \mathrm{fm}^2$. Combined with existing measurements of the Debye-Waller factor and charge radius, the measured structure factors also improve constraints on the strength of a Yukawa-modification to gravity by an order of magnitude over the 20 pm to 10 nm length scale range.

nucl-ex

Increased interference fringe visibility from the post fabrication heat treatment of a perfect crystal silicon neutron interferometer

Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the same base preserves Bragg plane alignment, but if the interferometer contains crystallographic misalignments of greater than about 10 nrad between the blades, interference fringe visibility begins to suffer. Additionally, the parallelism, thickness, and distance between the blades must be machined to micron tolerances. Traditionally, interferometers do not exhibit usable interference fringe visibility until 30 $μ$m to 60 $μ$m of machining surface damage is chemically etched away. However, if too much material is removed, the uneven etch rates across the interferometer cause the shape of the crystal blades to be outside of the required tolerances. As a result, the ultimate interference fringe visibility varies widely among neutron interferometers that are created under similar conditions. We find that annealing a previously etched interferometer at $800^\circ \mathrm{C}$ dramatically increased interference fringe visibility from 23 % to 90 %. The Bragg plane misalignments were also measured before and after annealing using neutron rocking curve interference peaks, showing that Bragg plane alignment was improved across the interferometer after annealing. This suggests that current interferometers with low fringe visibility may be salvageable and that annealing may become an important step in the fabrication process of future neutron interferometers, leading to less need for chemical etching and larger, more exotic neutron interferometers.

physics.ins-det

Spin-Orbit States of Neutron Wavepackets

We propose a method to prepare an entangled spin-orbit state between the spin and the orbital angular momenta of a neutron wavepacket. This spin-orbit state is created by passing neutrons through the center of a quadrupole magnetic field, which provides a coupling between the spin and orbital degrees of freedom. A Ramsey fringe type measurement is suggested as a means of verifying the spin-orbit correlations.

quant-ph

Broadband Neutron Interferometer

We demonstrate a two phase-grating, multi-beam neutron interferometer by using a modified Ronchi setup in a far-field regime. The functionality of the interferometer is based on the universal \moire effect that was recently implemented for X-ray phase-contrast imaging in the far-field regime. Interference fringes were achieved with monochromatic, bichromatic, and polychromatic neutron beams; for both continuous and pulsed beams. This far-field neutron interferometry allows for the utilization of the full neutron flux for precise measurements of potential gradients, and expands neutron phase-contrast imaging techniques to more intense polycromatic neutron beams.

physics.ins-det

Demonstration of a white beam far-field neutron interferometer for spatially resolved small angle neutron scattering

We provide the first demonstration that a neutron far-field interferometer can be employed to measure the microstructure of a sample. The interferometer is based on the moiré pattern of two phase modulating gratings which was previously realized in hard x-ray and visible light experiments. The autocorrelation length of this interferometer, and hence the microstructure length scale that is probed, is proportional to the grating spacing and the neutron wavelength, and can be varied over several orders of magnitude for one pair of gratings. We compare our measurements of the change in visibility from monodisperse samples with calculations which show reasonable agreement. The potential advantages of a far-field neutron interferometer include high fringe visibility in a polychromatic beam (over 30 %), no requirement for an absorbing grating to resolve the interference fringes, and the ability to measure the microstructure in the length scale range of 100 nm to 10 \mum by varying either the grating spacing or neutron wavelength with a broad wavelength range and single set of gratings.

physics.ins-det

Quantum correlations in a noisy neutron interferometer

We investigate quantum coherences in the presence of noise by entangling the spin and path degrees of freedom of the output neutron beam from a noisy three-blade perfect crystal neutron interferometer. We find that in the presence of dephasing noise on the path degree of freedom the entanglement of the output state reduces to zero, however the quantum discord remains non-zero for all noise values. Hence even in the presence of strong phase noise non-classical correlations persist between the spin and path of the neutron beam. This indicates that measurements performed on the spin of the neutron beam will induce a disturbance on the path state. We calculate the effect of the spin measurement by observing the changes in the observed contrast of the interferometer for an output beam post-selected on a given spin state. In doing so we demonstrate that these measurements allow us to implement a quantum eraser, and a which-way measurement of the path taken by the neutron through the interferometer. While strong phase noise removes the quantum eraser, the spin-filtered which-way measurement is robust to phase noise. We experimentally demonstrate this disturbance by comparing the contrasts of the output beam with and without spin measurements of three neutron interferometers with varying noise strengths. This demonstrates that even in the presence of noise that suppresses path coherence and spin-path entanglement, a neutron interferometer still exhibits uniquely quantum behaviour.

quant-ph