SearcharxivSearch

arXiv subjects

Michael Guinchard

Publications and source records attributed to Michael Guinchard.

2 recordsLinked to original sources

Technical Proposal for the Atom Interferometer CERN Experiment (AICE) Facility

We present the technical proposal for the Atom Interferometer CERN Experiment (AICE), a $\mathcal{O}(100)$ m vertical atom interferometer to be installed against the wall of the PX46 access shaft to the LHC. AICE is conceived as a versatile and flexible long-baseline atom-interferometry facility whose primary scientific goal is probing for bosonic ultralight dark matter (ULDM) in a mass range inaccessible to other experiments, with a secondary goal of pioneering the exploration of gravitational waves (GWs) with frequencies in the range ${\sim}$0.03-3 Hz as a pathfinder for future longer-baseline detectors. The initial configuration employs ultracold $^{87}$Sr atoms in a single-photon 698-nm interferometer with three shaft-based atom sources in a multi-source gradiometer geometry, supported by one surface reference source for laser stabilisation and diagnostics, to target scalar ULDM. Operation with $^{88}$Sr will give sensitivity to axion-like particles (ALPs), vector ULDM with $B-L$ couplings and violation of the principle of equivalence, while a $^{171}$Yb upgrade will improve the sensitivity to $B-L$ couplings and equivalence violations. Probing the Einstein equivalence principle (EP) and measuring $\alpha$ will proceed in parallel with the ULDM searches. A conceptual feasibility study and a detailed technical implementation study have established that PX46 is a uniquely mature and implementation-ready site, with no technical showstoppers. Completing site preparation works during LS3 would enable the subsequent installation and operation of AICE without impacting HL-LHC operations. The detector design builds on the VLBAI and MAGIS experiments and the AION-10 Technical Design Report, scaling the strontium gradiometer architecture to the $\sim$100 m baseline. AICE is endorsed by the TVLBAI Proto-Collaboration, comprising 57 institutions in 22 countries.

hep-ex

Performance of a MQXF Nb3Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb3Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

physics.app-ph