SearcharxivSearch

arXiv subjects

Michael Tayler

Publications and source records attributed to Michael Tayler.

2 recordsLinked to original sources

High-sensitivity multichannel zero-to-ultralow field NMR with atomic magnetometer arrays

Despite its versatility and high chemical specificity, conventional NMR spectroscopy is limited in measurement throughput due to the need for high-homogeneity magnetic fields, necessitating sequential sample analysis, and bulky devices. Here, we propose a multichannel NMR device that overcomes these limitations that leverages the zero-to-ultralow field (ZULF) regime, where simultaneous detection of multiple samples is carried out via an array of compact optically pumped magnetometers (OPMs). A magnetic field is used only for pre-polarization, permitting the use of large-bore, high-field, inhomogeneous magnets that can accommodate many samples concurrently. Through systematic advances, we demonstrate high-sensitivity, high resolution ZULF NMR spectroscopy with sensitivity comparable to benchtop NMR systems. The spectroscopy remains robust without the need for field shimming for periods on the order of weeks. We show the detection of ZULF NMR signals from organic molecules without isotopic enrichment, and demonstrate the parallelized detection of three distinct samples simultaneously as a proof-of-concept, with the potential to scale further to over 100 channels at a cost comparable to high-resolution liquid state NMR systems. This work sets the stage for using multichannel "NMR camera" devices for inline reaction monitoring, robotic chemistry, quality control, and high-throughput assays.

physics.ins-det

Fast-field-cycling, ultralow-field nuclear magnetic relaxation dispersion

Optically pumped magnetometers (OPMs) based on alkali-atom vapors are ultra-sensitive devices for dc and low-frequency ac magnetic measurements. Here, in combination with fast-field-cycling hardware and high-resolution spectroscopic detection, we demonstrate applicability of OPMs in quantifying nuclear magnetic relaxation phenomena. Relaxation rate dispersion across the nT to mT field range enables quantitative investigation of extremely slow molecular motion correlations in the liquid state, with time constants >1 ms, and insight into the corresponding relaxation mechanisms. The 10-20 fT/$\sqrt{\mathrm{Hz}}$ sensitivity of an OPM between 10 Hz and 5.5 kHz $^1$H Larmor frequency suffices to detect magnetic resonance signals from $\sim$0.1 mL liquid volumes imbibed in simple mesoporous materials, or inside metal tubing, following nuclear spin prepolarization adjacent to the OPM. High-resolution spectroscopic detection can resolve inter-nucleus spin-spin couplings, further widening the scope of application to chemical systems. Expected limits of the technique regarding measurement of relaxation rates above 100 s$^{-1}$ are discussed.

physics.chem-ph