SearcharxivSearch

arXiv subjects

Michael Vissers

Publications and source records attributed to Michael Vissers.

At least 19 recordsLinked to original sources

Operation of Unshielded Kinetic-Inductance Traveling-Wave Parametric Amplifiers in Multi-Tesla Fields

Cryogenic parametric amplifiers are used to amplify radio-frequency signals for a range of applications in basic and applied science. Both Josephson Parametric Amplifiers and Josephson Traveling-Wave Parametric Amplifiers have been used as first-stage amplifiers enabling readout chains operating within a few quanta of the quantum limit. However, these devices are highly sensitive to magnetic fields, having critical current suppressed by the Fraunhofer effect, requiring substantial field-free zones. In a dark matter axion search experiment, axions convert to detectable microwave photons in the presence of a strong magnetic field, necessitating amplifiers that can reliably operate close to these environments. Kinetic-inductance Traveling-Wave Parametric Amplifiers (KTWPAs) may be the ideal candidate for this type of application having high critical magnetic field of the materials used throughout their construction. In this letter we demonstrate that KTWPAs can provide high gain (>20dB) over a multi-GHz bandwidth in spite of from multiple exposures to multi-Tesla fields. Further, we explore operational characteristics of these devices under harsh conditions as a function of overall field strength, device orientation within the field, applied bias current, and pump power & frequency. In so doing, we find KTWPA gain vanishes in devices oriented perpendicularly to a field of 0.02T, but gain values >10dB are achievable in fields over 1T when oriented near~parallel to the device plane, with peak gain achieved with an applied 0.25T to 0.5T field. It is our expectation that KTWPAs will expand the accessibility of quantum-limited RF measurements in the presence of Tesla-scale fields.

hep-ex

CCAT: Characterization of the first science-grade MKID array for the Prime-Cam 850 GHz module

The Fred Young Submillimeter Telescope (FYST) is a 6-meter crossed-Dragone telescope developed by the CCAT collaboration. Sited at 5600 m on Cerro Chajnantor in the Atacama Plateau of Chile, FYST aims to provide superior atmospheric transmission and a wide field of view for submillimeter observations. Prime-Cam is a first-generation instrument for FYST designed to house up to seven separate instrument modules. Among these, the 850 GHz module represents the highest-frequency band and is optimized for ultra-sensitive broadband polarimetry and imaging. This module is designed to deploy ~38,000 polarization-sensitive lumped-element titanium-nitride (TiN) microwave kinetic inductance detectors (MKIDs) across three arrays. Thus the 850 GHz module will have the most submillimeter MKIDs in a single instrument module to date. These detectors have adopted a novel two-octave design to maximize the multiplexing achieved using a RFSoC readout system. We review the design parameters and fabrication process for the first 850 GHz science-grade array. The preliminary measurements of the array show a fabrication yield of 99%, highlighting the successful application of the design and fabrication process. We further present the cryogenic characterization of the first full MKID array developed for the Prime-Cam 850 GHz module. Multiple tests were performed on the devices including resonator frequency mapping, quality factor measurements, optical load sweeps and noise performance. From these measurements, we discuss the measured optical efficiency, sensitivity, and uniformity across the array and the expected on-sky performance of the module. The 850 GHz module will be deployed for observing in 2027.

astro-ph.IM

Multi-stage Quantum Amplifier Readout Chain

Multi-stage cryogenic readout chains with a wide bandwidth and added noise within a few quanta of the quantum limit are frequently constructed using traveling-wave parametric amplifiers (TWPAs) as the first stage, and a semiconductor amplifier as the second stage. Unfortunately for highly-scaled superconducting detector arrays, or quantum information systems, and space-based observatories, the power dissipation of the semiconductor amplifier becomes problematic from the perspective of available cryogenic cooling power at \mbox{3~K to 4~K}. Here we demonstrate a readout chain based on a two-stage kinetic inductance TWPA (KTWPA). This quantum-amplifier-based-readout-chain (QARC) provides sufficient gain that a cryogenic semiconductor follow-on amplifier can be eliminated without degradation of the system noise. In this way, the QARC dissipates approximately three orders of magnitude less power than readout chains containing semiconductor amplifiers while adding noise of less than 2~quanta over a 1~GHz bandwidth. In addition, by leveraging the high power handling of kinetic inductance technology, the QARC maintains an input compression point of -93~dBm, which exceeds that of many contemporary Josephson-junction-based parametric amplifiers.

quant-ph

CCAT: Silicon-Platelet Feedhorns for Submillimeter Wavelengths

Silicon-platelet feedhorn arrays are an established technology at millimeter wavelengths that, for some applications, can provide significant advantages over traditional direct-machined metal feedhorns. The Prime-Cam focal planes operating in the 350 GHz ($\sim$860 $\mathrm{\mu}$m) and 850 GHz ($\sim$350 $\mathrm{\mu}$m) bands are anticipated to carry the first silicon-platelet feedhorn arrays to operate fully at submillimeter wavelengths, representing a significant step forward in the application of this technology. In particular, the feedhorns designed for operation in the 850 GHz band represent a 3x increase in frequency compared to previously demonstrated and deployed devices of this type. Here we present a demonstration of silicon-platelet feedhorns at these submillimeter wavelengths, including in-lab performance characterization. We present fabrication metrology, room-temperature beammaps, and cryogenic optical efficiency measurements where the feedhorns are coupled to prototype CCAT Prime-Cam detectors. We show that feedhorn performance measurements are well matched to simulation and compare that performance directly to traditional, direct-machined metal feedhorns.

astro-ph.IM

CCAT: Magnetic Sensitivity Measurements of Kinetic Inductance Detectors

The CCAT Observatory is a ground-based submillimeter to millimeter experiment located on Cerro Chajnantor in the Atacama Desert, at an altitude of 5,600 meters. CCAT features the 6-meter Fred Young Submillimeter Telescope (FYST), which will cover frequency bands from 210 GHz to 850 GHz using its first-generation science instrument, Prime-Cam. The detectors used in Prime-Cam are feedhorn-coupled, lumped-element superconducting microwave kinetic inductance detectors (KIDs). The telescope will perform wide-area surveys at speeds on the order of degrees per second. During telescope operation, the KIDs are exposed to changes in the magnetic field caused by the telescope's movement through Earth's magnetic field and internal sources within the telescope. We present and compare measurements of the magnetic sensitivity of three different CCAT KID designs at 100 mK. The measurements are conducted in a dilution refrigerator (DR) with a set of room temperature Helmholtz coils positioned around the DR. We discuss the implications of these results for CCAT field operations.

astro-ph.IM

High-Throughput Microwave Package for Precise Superconducting Device Measurement

Cryogenic microwave measurement of superconducting quantum devices is complicated by the packaging required to connect devices to control and readout circuitry. In this work, we outline the design and experimental demonstration of a wirebond-free, PCB-free, drop-in microwave package for on-chip superconducting quantum devices. The package is composed of a superconducting aluminum cavity with a suspended tungsten transmission pin. The fundamental package cavity mode is far detuned from the 4 GHz to 8 GHz band of interest, and the pin transmission exhibits less than 3 dB of ripple across this range. We demonstrate the use of this package to extract the loss tangent of superconducting ring resonators, measuring a value of (1.10 +- 0.09) x 10^-6, which agrees with measurements of lambda/4 resonators in wirebond-based packaging. This high-throughput measurement system will allow the rapid generation of large datasets for improving superconducting qubit performance, and facilitate time-sensitive surface passivation and oxide regrowth studies.

quant-ph

Thermal and Electrical Properties of Prototype Readout Components for CMB-S4

CMB-S4 is the fourth-generation ground-based cosmic microwave background project, designed to probe the early universe and cosmic inflation. CMB-S4 would achieve its science goals in part by dramatically increasing the number of transition edge sensor (TES) bolometer detectors on the sky. The detector readout system for CMB-S4 is time-division multiplexing (TDM) with a two-stage Superconducting Quantum Interference Device (SQUID) system. To accommodate the large increase in detectors, the size of our camera increases, placing physical constraints on the readout, its wiring, and its power dissipation. Therefore, to optimize readout performance, we need to balance competing design considerations such as thermal load and bandwidth. We present results characterizing the thermal and electrical performance of prototype components, including wiring and SQUID arrays for CMB-S4, and discuss the impact on overall system performance.

astro-ph.IM

Development of Silicon Micromachined Waveguide Filter-Banks for On-Chip Spectrometers

Development of high-speed, spatial-mapping spectrometers in the millimeter and far-infrared frequencies would enable entirely new research avenues in astronomy and cosmology. An "on-chip" spectrometer is one such technology that could enable Line Intensity Mapping. Recent work has shown the promise of high-speed imaging; however, a limiting factor is that many of these devices suffer from low optical efficiency. Here we present the fabrication of a metalized, Si waveguide filter-bank fabricated using deep reactive ion etching for use in millimeter spectroscopy. Our design simultaneously provides high-density pixel packing, high optical efficiency, high spectral resolution, and is readily compatible with simple and multiplexable MKID arrays. Gold plated test waveguide and filter show excellent match to simulations with a measured resolving power of 263 and a loss quality factor of 1116 at room temperature. The results show promise for extending the measurements to larger, multi-wavelength designs.

astro-ph.IM

Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers

Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to many of these arrays is the efficient use of focal plane area to achieve a large fill fraction of absorbers coupled to detectors. We are developing an integrated fabrication of soft X-ray transition edge sensors (TES) and microwave SQUID multiplexers ($μ$MUX) with the goal of maximizing the fill fraction of the focal plane area on a scale of many thousand pixel detectors. We will utilize lithographically defined high density interconnects to circumvent limitations in existing solutions that use wirebonds or flip-chip bonds. Here we report the first demonstration of combining TES and $μ$MUX processes into a single TES-System-on-a-Chip (TES-SoC) fabrication on a silicon wafer. The $μ$MUX SQUIDs and TES electrothermal feedback circuits are microfabricated first and protected with passivating SiO$_2$, then the TES devices and TES-to-SQUID interconnects are fabricated, and finally the protective layer is removed before the fabrication of the microwave resonators. We show that the microwave SQUIDs are functional and have reasonable yield, and that we are able to read out the transition temperature of the connected TESs using those SQUIDs.

physics.ins-det

CCAT: Design, Implementation, and Testing of a System to Read Out over 10,000 280 GHz KIDs using RFSoC Electronics

Over the past decade, kinetic inductance detectors (KIDs) have emerged as a viable superconducting technology for astrophysics at millimeter and submillimeter wavelengths. KIDs spanning 210 - 850 GHz across seven instrument modules will be deployed in the Prime-Cam instrument of CCAT Observatory's Fred Young Submillimeter Telescope at an elevation of 5600 m on Cerro Chajnantor in Chile's Atacama Desert. The natural frequency-division multiplexed readout of KIDs allows hundreds of detectors to be coupled to a single radio frequency (RF) transmission line, but requires sophisticated warm readout electronics. The FPGA-based Xilinx ZCU111 radio frequency system on chip (RFSoC) offers a promising and flexible solution to the challenge of warm readout. CCAT uses custom packaged RFSoCs to read out KIDs in the Prime-Cam instrument. Each RFSoC can simultaneously read out four RF channels with up to 1,000 detectors spanning a 512 MHz bandwidth per channel using the current firmware. We use five RFSoCs to read out the >10,000 KIDs in the broadband 280 GHz instrument module. Here, we describe and demonstrate the readout hardware, software and pipeline for the RFSoC system. We present a detector position map of the 280 GHz module focal plane and preliminary averaged spectral responses of a small subset of detectors from the TiN and first Al arrays. These measurements demonstrate our ability to simultaneously readout thousands of detectors, validate the end-to-end performance of the readout and optical systems, and represent a critical step toward reading out the ~100,000 KIDs in Prime-Cam in its future full capacity configuration.

astro-ph.IM

Compact Superconducting Kinetic Inductance Traveling Wave Parametric Amplifiers with On-chip rf Components

Quantum computing systems and fundamental physics experiments using superconducting technologies frequently require signal amplification chains operating near the quantum limit of added noise. Both Josephson parametric amplifiers (JPAs) and traveling wave parametric amplifiers (TWPAs) have been used as first-stage amplifiers to enable readout chains operating within a few quanta or less of the quantum limit. These devices are also presently entering the commercial industry. However, nearly all demonstrations and existing products require bulky external microwave components for interconnection and application of requisite biases. These components -- cabling interconnects, bias tees, directional couplers, and diplexers -- increase the overall amplifier footprint, installation complexity, and reduce already limited available cryogenic volumes. Additionally, these components introduce loss and reflections which impact the measurement efficiency and readout system noise performance; thus making it more difficult to operate near the quantum limit. Here we present the design and validation of microfabricated bias tees and directional couplers for operating three-wave mixing kinetic inductance TWPAs (KITs). We report the performance of KITs integrated with the microfabricated rf components. Using these devices we demonstrate reduction in the amplifier installation footprint by a factor of nearly five and elimination of all external, lossy microwave components previously required to operate a KIT. Our device displays a 2.8 GHz 3 dB bandwidth with a median true gain of 17.5 dB and median system noise of 3.4 quanta. These efforts represent the first full integration of all rf components mandatory for TWPA operation on-chip. Our results mark significant progress towards the miniaturization and simplification of parametric amplifier setups and will aid in their more widespread applicability.

quant-ph

CCAT: LED Mapping and Characterization of the 280 GHz TiN KID Array

Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as the superconducting material and has 3,456 individual detectors, while the other two arrays use aluminum. This paper presents the design and laboratory characterization of the 280 GHz TiN array, which is cooled below its critical temperature to ~0.1 K and read out over six RF feedlines. LED mapping, a technique for matching the measured resonant frequency of a detector to its physical position, was performed on the array so that the results can be used to lithographically trim the KID capacitors and increase the yield of the array by reducing frequency collisions. We present the methods and results of LED mapping the 280 GHz TiN KID array before deployment on FYST.

astro-ph.IM

Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation

Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.

quant-ph

CCAT: Nonlinear effects in 280 GHz aluminum kinetic inductance detectors

Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam's 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling approximately 10,000 detectors at the focal plane, all of which have been fabricated and are currently undergoing testing. One complication of fielding large arrays of KIDs under dynamic loading conditions is tuning the detector tone powers to maximize signal-to-noise while avoiding bifurcation due to the nonlinear kinetic inductance. For aluminum-based KIDs, this is further complicated by additional nonlinear effects which couple tone power to resonator quality factors and resonant frequencies. While both nonequilibrium quasiparticle dynamics and two-level system fluctuations have been shown to give rise to qualitatively similar distortions, modeling these effects alongside nonlinear kinetic inductance is inefficient when fitting thousands of resonators on-sky with existing models. For this reason, it is necessary to have a detailed understanding of the nonlinear effects across relevant detector loading conditions, including how they impact on on-sky noise and how to diagnose the detector's relative performance. We present a study of the competing nonlinearities seen in Prime-Cam's 280 GHz aluminum KIDs, with a particular emphasis on the resulting distortions to the resonator line shape and how these impact detector parameter estimation.

astro-ph.IM

CCAT: Comparisons of 280 GHz TiN and Al Kinetic Inductance Detector Arrays

The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submillimeter wavelengths. The first of these instrument modules, the 280 GHz module, will include ${\sim}$10,000 kinetic inductance detectors (KIDs) across three arrays. While the first array was fabricated out of tri-layer TiN/Ti/TiN, the other two arrays were fabricated out of a single layer of Al. This combination of materials within the same instrument provides a unique opportunity to directly compare the performance and noise properties of two different detector materials that are seeing increasing use within the field. We present preliminary comparisons here based on lab testing, along with a discussion of the potential impacts on operation when observing and translating raw data to science-grade maps.

astro-ph.IM

CCAT-prime: The 850 GHz camera for Prime-Cam on FYST

The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity mapping during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be the highest frequency module in Prime-Cam and the most novel for astronomical and cosmological surveys, taking full advantage of the atmospheric transparency at the high 5600 meter CCAT-prime siting on Cerro Chajnantor. With a 1.1 deg diameter field, the 850 GHz module will deploy ~40,000 Kinetic Inductance Detectors (KIDs) with Silicon platelet feedhorn coupling (both fabricated at NIST), and will provide unprecedented broadband intensity and polarization measurement capabilities. The 850 GHz module will be key to addressing pressing astrophysical questions regarding galaxy formation, Big Bang cosmology, and star formation within our own Galaxy. We present the motivation and overall design for the module, and initial laboratory characterization.

astro-ph.IM

CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam

The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.

astro-ph.IM

CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module

Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280-850 GHz broadband and spectroscopic measurements with microwave kinetic inductance detectors (MKIDs). CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.

astro-ph.IM