Searcharxiv⌕ Search

arXiv subjects

Michail E. Klontzas

Publications and source records attributed to Michail E. Klontzas.

8 recordsLinked to original sources

Cross Modality Image Translation In Medical Imaging Using Generative Frameworks

Magnetic Resonance Imaging (MRI), Computed Tomography (CT), and Positron Emission Tomography (PET) provide complementary information about tissues. Medical image-to-image (I2I) translation enables virtual scanning by synthesizing a target modality from a source one without requiring an additional acquisition. Despite growing interest, many methods operate on 2D slices, are evaluated on isolated tasks under different experimental settings, and lack clinically oriented assessment. This work presents a reproducible benchmark for 3D I2I translation in oncological imaging that compares seven generative models: three Generative Adversarial Networks (Pix2Pix, CycleGAN, and SRGAN) and four latent models (Latent Diffusion Model, Latent Diffusion Model+ControlNet, Brownian Bridge, and Flow Matching). The benchmark comprises 77 experiments across eleven configurations drawn from five datasets, covering three anatomical regions (head/neck, lung, and pelvis) and four translation directions (cone-beam CT to CT, MRI to CT, CT to PET, and T2-weighted MRI to T2-FLAIR). Under the evaluated configurations, SRGAN achieves the highest quantitative image fidelity across all tasks, while latent models perform less well, due to information loss introduced by the variational autoencoder. A tumor-level analysis reveals that all models struggle with small lesions and that, in CT to PET synthesis, models reproduce tumor shape more reliably than tracer uptake values. A Visual Turing test involving 17 physicians, including 15 radiologists, shows near-chance classification accuracy (56.7\%), suggesting that experts struggle to distinguish real from synthetic volumes under the viewing conditions of the study. Expert preferences do not follow quantitative rankings, exposing a dissociation between quantitative metrics and clinical preference.

cs.CV↗

The MAMA-MIA Challenge: Advancing Generalizability and Fairness in Breast MRI Tumor Segmentation and Treatment Response Prediction

Breast cancer is the most frequently diagnosed malignancy among women worldwide and a leading cause of cancer-related mortality. Dynamic contrast-enhanced magnetic resonance imaging plays a central role in tumor characterization and treatment monitoring, particularly in patients receiving neoadjuvant chemotherapy. However, existing artificial intelligence models for breast magnetic resonance imaging are typically developed and evaluated using heterogeneous datasets, study populations, and assessment protocols, making direct comparison difficult and limiting understanding of model robustness across institutions and clinically relevant patient subgroups. The MAMA-MIA Challenge was designed to address these challenges by providing a standardized benchmark for the joint evaluation of primary tumor segmentation and prediction of pathologic complete response using pre-treatment magnetic resonance imaging only. The training cohort comprised 1,506 patients from multiple institutions in the United States, while evaluation was conducted on an external test set of 574 patients from three independent European centers to assess cross-continental and cross-institutional generalization. A unified scoring framework combined predictive performance with subgroup consistency across age, menopausal status, and breast density. Twenty-six international teams participated in the final evaluation phase. Results demonstrate substantial performance variability under a common external evaluation framework and reveal trade-offs between overall accuracy and subgroup fairness. The challenge provides standardized datasets, evaluation protocols, and public resources to promote the development of robust and equitable artificial intelligence systems for breast cancer imaging.

cs.CV↗

ReclAIm: A Multi-Agent Framework for Monitoring and Correcting Performance Decline in Medical Imaging AI

Purpose: To develop and evaluate a multi-agent framework (ReclAIm) for automated monitoring, detection, and correction of performance decline in medical image classification models. Materials and Methods: ReclAIm is a large language model-based multi-agent system that operates through natural language interaction. A master agent coordinating three task-specific agents performed performance evaluation and triggered fine-tuning when substantial performance declines were detected. The fine-tuning workflow incorporated data augmentation, class imbalance handling, and a parameter-anchoring regularization strategy to limit catastrophic forgetting. The system was benchmarked using multiple imaging datasets, including brain MRI, chest CT, and chest radiography, partitioned into model development, inference (performance monitoring), and fine-tuning subsets (60%:20%:20%). Results: ReclAIm successfully orchestrated training, evaluation, and performance monitoring across all datasets. Performance discrepancies between test and inference data were detected in 8 of 18 models, prompting fine-tuning workflows that reduced performance gaps. In cases with declines of up to 40.6% (cardiomegaly dataset, InceptionV3), fine-tuning restored performance metrics to within 2% of baseline values. Conclusion: ReclAIm provides a prototype framework for automated monitoring and targeted fine-tuning of medical image classification models, with a natural language interface designed to support accessibility in research and potential clinical applications.

cs.MA↗

DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI

Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes. Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.

physics.med-ph↗

OpenRad: a Curated Repository of Open-access AI models for Radiology

The rapid developments in artificial intelligence (AI) research in radiology have produced numerous models that are scattered across various platforms and sources, limiting discoverability, reproducibility and clinical translation. Herein, OpenRad was created, a curated, standardized, open-access repository that aggregates radiology AI models and providing details such as the availability of pretrained weights and interactive applications. Retrospective analysis of peer reviewed literature and preprints indexed in PubMed, arXiv and Scopus was performed until Dec 2025 (n = 5239 records). Model records were generated using a locally hosted LLM (gpt-oss:120b), based on the RSNA AI Roadmap JSON schema, and manually verified by ten expert reviewers. Stability of LLM outputs was assessed on 225 randomly selected papers using text similarity metrics. A total of 1694 articles were included after review. Included models span all imaging modalities (CT, MRI, X-ray, US) and radiology subspecialties. Automated extraction demonstrated high stability for structured fields (Levenshtein ratio > 90%), with 78.5% of record edits being characterized as minor during expert review. Statistical analysis of the repository revealed CNN and transformer architectures as dominant, while MRI was the most commonly used modality (in 621 neuroradiology AI models). Research output was mostly concentrated in China and the United States. The OpenRad web interface enables model discovery via keyword search and filters for modality, subspecialty, intended use, verification status and demo availability, alongside live statistics. The community can contribute new models through a dedicated portal. OpenRad contains approx. 1700 open access, curated radiology AI models with standardized metadata, supplemented with analysis of code repositories, thereby creating a comprehensive, searchable resource for the radiology community.

cs.AI↗

mAIstro: an open-source multi-agentic system for automated end-to-end development of radiomics and deep learning models for medical imaging

Agentic systems built on large language models (LLMs) offer promising capabilities for automating complex workflows in healthcare AI. We introduce mAIstro, an open-source, autonomous multi-agentic framework for end-to-end development and deployment of medical AI models. The system orchestrates exploratory data analysis, radiomic feature extraction, image segmentation, classification, and regression through a natural language interface, requiring no coding from the user. Built on a modular architecture, mAIstro supports both open- and closed-source LLMs, and was evaluated using a large and diverse set of prompts across 16 open-source datasets, covering a wide range of imaging modalities, anatomical regions, and data types. The agents successfully executed all tasks, producing interpretable outputs and validated models. This work presents the first agentic framework capable of unifying data analysis, AI model development, and inference across varied healthcare applications, offering a reproducible and extensible foundation for clinical and research AI integration. The code is available at: https://github.com/eltzanis/mAIstro

cs.LG↗

Accurate and Energy Efficient: Local Retrieval-Augmented Generation Models Outperform Commercial Large Language Models in Medical Tasks

Background The increasing adoption of Artificial Intelligence (AI) in healthcare has sparked growing concerns about its environmental and ethical implications. Commercial Large Language Models (LLMs), such as ChatGPT and DeepSeek, require substantial resources, while the utilization of these systems for medical purposes raises critical issues regarding patient privacy and safety. Methods We developed a customizable Retrieval-Augmented Generation (RAG) framework for medical tasks, which monitors its energy usage and CO2 emissions. This system was then used to create RAGs based on various open-source LLMs. The tested models included both general purpose models like llama3.1:8b and medgemma-4b-it, which is medical-domain specific. The best RAGs performance and energy consumption was compared to DeepSeekV3-R1 and OpenAIs o4-mini model. A dataset of medical questions was used for the evaluation. Results Custom RAG models outperformed commercial models in accuracy and energy consumption. The RAG model built on llama3.1:8B achieved the highest accuracy (58.5%) and was significantly better than other models, including o4-mini and DeepSeekV3-R1. The llama3.1-RAG also exhibited the lowest energy consumption and CO2 footprint among all models, with a Performance per kWh of 0.52 and a total CO2 emission of 473g. Compared to o4-mini, the llama3.1-RAG achieved 2.7x times more accuracy points per kWh and 172% less electricity usage while maintaining higher accuracy. Conclusion Our study demonstrates that local LLMs can be leveraged to develop RAGs that outperform commercial, online LLMs in medical tasks, while having a smaller environmental impact. Our modular framework promotes sustainable AI development, reducing electricity usage and aligning with the UNs Sustainable Development Goals.

cs.AI↗

A large-scale multicenter breast cancer DCE-MRI benchmark dataset with expert segmentations

Artificial Intelligence (AI) research in breast cancer Magnetic Resonance Imaging (MRI) faces challenges due to limited expert-labeled segmentations. To address this, we present a multicenter dataset of 1506 pre-treatment T1-weighted dynamic contrast-enhanced MRI cases, including expert annotations of primary tumors and non-mass-enhanced regions. The dataset integrates imaging data from four collections in The Cancer Imaging Archive (TCIA), where only 163 cases with expert segmentations were initially available. To facilitate the annotation process, a deep learning model was trained to produce preliminary segmentations for the remaining cases. These were subsequently corrected and verified by 16 breast cancer experts (averaging 9 years of experience), creating a fully annotated dataset. Additionally, the dataset includes 49 harmonized clinical and demographic variables, as well as pre-trained weights for a baseline nnU-Net model trained on the annotated data. This resource addresses a critical gap in publicly available breast cancer datasets, enabling the development, validation, and benchmarking of advanced deep learning models, thus driving progress in breast cancer diagnostics, treatment response prediction, and personalized care.

cs.CV↗