Optimization of 3D diamond detectors with graphitized electrodes based on an innovative numerical simulation

Future experiments at hadron colliders require an evolution of the tracking sensors to ensure sufficient radiation hardness as well as space and time resolution to handle unprecedented particle fluxes. 3D diamond sensors with laser-graphitized electrodes are promising candidates due to their strong binding energy, small atomic number, and high carrier mobility. However, the high resistance of the engraved electrodes delays the propagation of the induced signals towards the readout electronics, thereby degrading the precision of the timing measurements. So far, this effect has been the dominant factor limiting the time resolution of these devices, with other contributions, such as those due to electric field inhomogeneities or electronic noise, typically neglected. Recent advancements in graphitization technology, however, motivate a renewed effort in modeling signal generation in 3D diamond detectors, to achieve more reliable predictions. To this purpose, we apply an extended version of the Ramo-Shockley theorem, describing the effect of signal propagation as a time-dependent weighting potential, obtained by numerically solving the Maxwell's equations in a quasi-static approximation. We developed a custom spectral method solver and validated it against COMSOL MultiPhysics. The response of the modeled sensor to a beam of particles is then simulated using Garfield++ and is compared to the data acquired in a beam test carried on in 2021 by the TimeSPOT Collaboration at the SPS, at CERN. Based on the results obtained with this simulation workflow, we conclude that reducing the resistivity of the graphitic columns remains the priority for significantly improving the time resolution of 3D diamond detectors. Once achieved, optimization of the detector geometry and readout electronics design will become equally important steps to further enhance the timing performance of these devices.

physics.ins-det

New results from an extensive aging test on bakelite Resistive Plate Chambers

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOhm to more than 250 MOhm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm2 to less than 0.15 kHz/cm2 is also found.

physics.ins-det

First results from an aging test of a prototype RPC for the LHCb Muon System

Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm$^2$, corresponding to about 4 years of LHCb running at the highest background rate. The performance of the chamber has been studied under several photon flux values exploiting a muon beam. A degradation of the rate capability above 1 kHz/cm$^2$ is observed, which can be correlated to a sizeable increase of resistivity of the chamber plates. An increase of the chamber dark current is also observed. The chamber performance is found to fulfill the LHCb operation requirements.

physics.ins-det

Preliminary results of an aging test of RPC chambers for the LHCb Muon System

The preliminary results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge density of 0.42 C/cm^2, corresponding to about 4 years of LHCb running at the highest background rate. We observe a rise in the dark current and noise measured with source off. The current drawn with source on steadily decreased, possibly indicating an increase of resistivity of the chamber plates. The performance of the chamber, studied with a muon beam under several photon flux values, is found to still fulfill the LHCb operation requirements.