SearcharxivSearch

arXiv subjects

Miguel Daal

Publications and source records attributed to Miguel Daal.

15 recordsLinked to original sources

SENSEI: A Search for Diurnal Modulation in sub-GeV Dark Matter Scattering

Dark matter particles with sufficiently large interactions with ordinary matter can scatter in the Earth's atmosphere and crust before reaching an underground detector. This Earth-shielding effect can induce a directional dependence in the dark matter flux, leading to a sidereal daily modulation in the signal rate. We perform a search for such a modulation using data from the SENSEI experiment, targeting MeV-scale dark matter. We achieve an order-of-magnitude improvement in sensitivity over previous direct-detection bounds for dark-matter masses below 1 MeV, assuming the Standard Halo Model with a Maxwell--Boltzmann velocity distribution, and constrain the amplitude of a general daily modulation signal to be below 6.8 electrons per gram per day.

hep-ex

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of $(1.39 \pm 0.11) \times 10^{-5}$ e$^-$/pix/day, corresponding to $(39.8 \pm 3.1)$ e$^-$/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the near-infrared-ultraviolet range. We use these data to obtain a 90% confidence level upper bound of $1.53 \times 10^{-5}$ e$^-$/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

astro-ph.CO

SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB

We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

astro-ph.CO

Improved Flexible Coaxial Ribbon Cable for High-Density Superconducting Arrays

Superconducting arrays often require specialized, high-density cryogenic cabling capable of transporting electrical signals across temperature stages with minimal loss, crosstalk, and thermal conductivity. We report improvements to the design and fabrication of previously published superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). We used 3D electromagnetic simulations to inform design changes to improve the characteristic impedance of the cable and the connector transition. We increased the center conductor diameter from 0.003 inches to 0.005 inches which lowered the cable characteristic impedance from $\sim$60 $Ω$ to $\sim$53 $Ω$. This change had a negligible impact on the computed heat load which we estimate to be 5 nW per trace from 1 K to 100 mK with a 1-ft cable. This is approximately half the heat load calculated for the smallest commercially available superconducting coax. We also modified the transition board to include a capacitive coupling between the upper ground plane and signal traces that mitigates the inductive transition. We tested these changes in a 5-trace, 1-ft long cable at 4 K and found the microwave transmission improved from 6 dB to 1.5 dB of attenuation at 8 GHz. This loss is comparable to commercial superconducting coax and 3$\times$ lower than commercial NbTi-on-polyimide flex cables at 8 GHz. The nearest-neighbor forward crosstalk remained less than -40 dB at 8 GHz. We compare key performance metrics with commercially available superconducting coax and NbTi-on-polyimide flex cables and we share initial progress on commercialization of this technology by Maybell Quantum Industries.

cond-mat.supr-con

SCExAO and Keck Direct Imaging Discovery of a Low-Mass Companion Around the Accelerating F5 Star HIP 5319

We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of T=3200 K and surface gravity log($g$)=5.5. Using the relative astrometry for HIP 5319 B from CHARIS and NIRC2 and absolute astrometry for the primary from $Gaia$ and $Hipparcos$ and adopting a log-normal prior assumption for the companion mass, we measure a dynamical mass for HIP 5319 B of $31^{+35}_{-11}M_{\rm J}$, a semimajor axis of $18.6^{+10}_{-4.1}$ au, an inclination of $69.4^{+5.6}_{-15}$ degrees, and an eccentricity of $0.42^{+0.39}_{-0.29}$. However, using an alternate prior for our dynamical model yields a much higher mass of 128$^{+127}_{-88}M_{\rm J}$. Using data taken with the LCOGT NRES instrument we also show that the primary HIP 5319 A is a single star in contrast to previous characterizations of the system as a spectroscopic binary. This work underscores the importance of assumed priors in dynamical models for companions detected with imaging and astrometry and the need to have an updated inventory of system measurements.

astro-ph.SR

Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors

Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and estimating each photon's energy. The resolving power of non-membrane MKIDs has remained stubbornly around 10 at 1 $μ$m despite significant improvements in the system noise. Here we show that the resolving power can be roughly doubled with a simple bilayer design without needing to place the device on a membrane, avoiding a significant increase in fabrication complexity. Based on modeling of the phonon propagation, we find that the majority of the improvement comes from the inability of high energy phonons to enter the additional layer due to the lack of available phonon states.

astro-ph.IM

SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

astro-ph.SR

Improving the dynamic range of single photon counting kinetic inductance detectors

We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium MKID designed to be sensitive to photons with wavelengths in the 800 to 1300 nm range. The new coordinates allow the detector to resolve photons with wavelengths down to 400 nm, raising the resolving power at that wavelength from 6.8 to 17.

astro-ph.IM

The MKID Exoplanet Camera for Subaru SCExAO

We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.

astro-ph.IM

Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays

Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax

physics.ins-det

Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors

We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $μ$s and resolving powers of ~9 at 800 nm.

astro-ph.IM

Enabling the next generation of scientific discoveries by embracing photonic technologies

The fields of Astronomy and Astrophysics are technology limited, where the advent and application of new technologies to astronomy usher in a flood of discoveries altering our understanding of the Universe (e.g., recent cases include LIGO and the GRAVITY instrument at the VLTI). Currently, the field of astronomical spectroscopy is rapidly approaching an impasse: the size and cost of instruments, especially multi-object and integral field spectrographs for extremely large telescopes (ELTs), are pushing the limits of what is feasible, requiring optical components at the very edge of achievable size and performance. For these reasons, astronomers are increasingly looking for innovative solutions like photonic technologies that promote instrument miniaturization and simplification, while providing superior performance. Astronomers have long been aware of the potential of photonic technologies. The goal of this white paper is to draw attention to key photonic technologies and developments over the past two decades and demonstrate there is new momentum in this arena. We outline where the most critical efforts should be focused over the coming decade in order to move towards realizing a fully photonic instrument. A relatively small investment in this technology will advance astronomical photonics to a level where it can reliably be used to solve challenging instrument design limitations. For the benefit of both ground and space borne instruments alike, an endorsement from the National Academy of Sciences decadal survey will ensure that such solutions are set on a path to their full scientific exploitation, which may one day address a broad range of science cases outlined in the KSPs.

astro-ph.IM

Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s

Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.

astro-ph.IM

A semi-empirical model for two-level system noise in superconducting microresonators

We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explained by a simple semi-empirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise.

cond-mat.supr-con

Experimental evidence for a surface distribution of two-level systems in superconducting lithographed microwave resonators

We present measurements of the temperature-dependent frequency shift of five niobium superconducting coplanar waveguide microresonators with center strip widths ranging from 3 $μ$m to 50 $μ$m, taken at temperatures in the range 100-800 mK, far below the 9.2 K transition temperature of niobium. These data agree well with the two-level system (TLS) theory. Fits to this theory provide information on the number of TLS that interact with each resonator geometry. The geometrical scaling indicates a surface distribution of TLS, and the data are consistent with a TLS surface layer thickness of order a few nm, as might be expected for a native oxide layer.

cond-mat.supr-con