SearcharxivSearch

arXiv subjects

Miguel Lozano

Publications and source records attributed to Miguel Lozano.

3 recordsLinked to original sources

A robust shape model for blood vessels analysis

The availability of digital twins for the cardiovascular system will enable insightful computational tools both for research and clinical practice. This, however, demands robust and well defined models and methods for the different steps involved in the process. We present a vessel coordinate system (VCS) that enables the unanbiguous definition of locations in a vessel section, by adapting the idea of cylindrical coordinates to the vessel geometry. Using the VCS model, point correspondence can be defined among different samples of a cohort, allowing data transfer, quantitative comparison, shape coregistration or population analysis. Furthermore, the VCS model allows for the generation of specific meshes (e.g. cylindrical grids, ogrids) necessary for an accurate reconstruction of the geometries used in fluid simulations. We provide the technical details for coordinates computation and discuss the assumptions taken to guarantee that they are well defined. The VCS model is tested in a series of applications. We present a robust, low dimensional, patient specific vascular model and use it to study phenotype variability analysis of the thoracic aorta within a cohort of patients. Point correspondence is exploited to build an haemodynamics atlas of the aorta for the same cohort. The atlas originates from fluid simulations (Navier-Stokes with Finite Volume Method) conducted using OpenFOAMv10. We finally present a relevant discussion on the VCS model, which covers its impact in important areas such as shape modeling and computer fluids dynamics (CFD).

cs.CE

Unsupervised stratification of patients with myocardial infarction based on imaging and in-silico biomarkers

This study presents a novel methodology for stratifying post-myocardial infarction patients at risk of ventricular arrhythmias using patient-specific 3D cardiac models derived from late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) images. The method integrates imaging and computational simulation with a simplified cellular automaton model, Arrhythmic3D, enabling rapid and accurate VA risk assessment in clinical timeframes. Applied to 51 patients, the model generated thousands of personalized simulations to evaluate arrhythmia inducibility and predict VA risk. Key findings include the identification of slow conduction channels (SCCs) within scar tissue as critical to reentrant arrhythmias and the localization of high-risk zones for potential intervention. The Arrhythmic Risk Score (ARRISK), developed from simulation results, demonstrated strong concordance with clinical outcomes and outperformed traditional imaging-based risk stratification. The methodology is fully automated, requiring minimal user intervention, and offers a promising tool for improving precision medicine in cardiac care by enhancing patient-specific arrhythmia risk assessment and guiding treatment strategies.

cs.CE

Slow Extraction of Charged Ion Pulses from the REXEBIS

The Isotope mass Separator On-Line DEvice (ISOLDE) facility located at CERN, produces and transports Radioactive Ion Beams (RIBs) at low or high energy through the REX/HIE-ISOLDE linear accelerator, for nuclear physics, astrophysics, solid-state physics and applied-physics purposes. Increasing the charge state of the ions is a prerequisite for efficient acceleration and is accomplished by an Electron Beam Ion Source (REXEBIS). For more effective event discrimination at the experimental detectors, such as the MINIBALL spectrometer, it is advantageous to increase the pulse width of extracted ions from this EBIS. A Slow Extraction scheme is presented which uses a function comprised of discrete voltage steps to apply the extraction potential to the EBIS trap barrier. This function effectively stretches the pulse length of both stable and radioactive ion beams, with different mass-to-charge ratios and provides for extracted pulse widths in the millisecond range. Key operational parameters of the EBIS impacting the average ionic temperature and its axial energy spread are discussed, in order to anticipate changes in the resulting ion pulse time structures during experimental runs.

physics.acc-ph