SearcharxivSearch

arXiv subjects

Miki Kurihara

Publications and source records attributed to Miki Kurihara.

6 recordsLinked to original sources

Fe K{\alpha} equivalent-width mapping with 3D radiative transfer calculation: A general model and application to the RS Canum Venaticorum-type stars with XRISM/Resolve

The Fe K $\alpha$ fluorescence line at 6.4 keV has long been used to probe the relative geometry between photoionizing X-ray sources and surrounding cold material in a wide range of astrophysical systems. With the advent of the X-ray microcalorimeter XRISM/Resolve, Fe K $\alpha$ lines with equivalent widths down to $\sim 5$ eV-previously inaccessible-are now detectable, and even non-detections can place upper limits of a few eV, making non-detections themselves valuable for constraining the geometry. Considering that Fe K $\alpha$-based geometric diagnostics are entering a new stage in the microcalorimeter era, we present Fe K $\alpha$ equivalent-width maps computed with the three-dimensional Monte Carlo radiative-transfer code SKIRT for a generalized configuration consisting of a spherical reflector of radius $R_{*}$ and a point source located at a height $h$ above the surface. The equivalent-width maps exhibit two characteristic features: (1) an increase toward the center of the projected surface of the sphere; and (2) an overall decrease with increasing $h/R_{*}$. The key point is that we confirm these features for equivalent widths of $< 40$ eV, a regime that has become accessible for the first time thanks to the improved detection threshold from $\sim 50$ eV with Chandra/HETG to $\sim 5$ eV with XRISM/Resolve. As an illustrative application, we compare the maps with XRISM/Resolve spectra of three RS Canum Venaticorum-type stars (GT Muscae, $\sigma$ Geminorum, and HR 1099) and constrain the locations of the flare loop and coronal bright points in these systems. Because the maps are constructed for a highly generalized point-source--spherical-reflector geometry, they are readily applicable to many other objects, including X-ray binaries and cataclysmic variables.

astro-ph.HE

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of $\sim 10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7--10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5--7.0 keV), we resolved the inner-shell lines of Fe XIX--XXIV as well as the outer-shell lines of Fe XXV--XXVI. These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1--10 keV (roughly 10--100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

astro-ph.SR

Spectroscopic diagnostics of high-temperature plasma in stellar corona using Fe XXIV--XXVI K-shell lines with XRISM

The RS CVn type binary star GT Mus was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV--XXVI K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional onization equilibrium (CIE) and Maxwell electron energy distribution with a single-temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$α$, Ly$α$, and He$β$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with a thermal broadening of Fe XXV and the broadband fitting results in the 1.7--10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $κ$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

astro-ph.HE

High-velocity blue-shifted Fe XXV He$α$ line during a superflare of the RS CVn-type star IM Peg

Monitor of All-sky X-ray Image (MAXI) detected a superflare, releasing $5\times 10^{37}$ erg in 2$-$10 keV, of the RS CVn-type star IM Peg at 10:41 UT on 2023 July 23 with its Gas Slit Camera (GSC; 2$-$30 keV). We conducted X-ray follow-up observations of the superflare with Neutron Star Interior Composition ExploreR (NICER; 0.2$-$12 keV) starting at 16:52 UT on July 23 until 06:00 UT on August 2. NICER X-ray spectra clearly showed emission lines of the Fe XXV He$α$ and Fe XXVI Ly$α$ for $\sim 1.5$ days since the MAXI detection. The Fe XXV He$α$ line was blue-shifted with its maximum Doppler velocity reaching $-2200 \pm 600$ $\mathrm{km \: s^{-1}}$, suggesting an upward-moving plasma during the flare, such as a coronal mass ejection (CME) and/or chromospheric evaporation. This is the first case that the Fe XXV He$α$ line is blue-shifted during a stellar flare and its velocity overwhelmingly exceeds the escape velocity of the star ($-230$ $\mathrm{km \: s^{-1}}$). One hour before the most pronounced blueshift detection, a signature of reheating the flare plasma was observed. We discuss the origin of the blueshift, a CME or high-velocity chromospheric evaporation.

astro-ph.SR

Investigation of non-equilibrium ionization plasma during a giant flare of UX Arietis triggered with MAXI and observed with NICER

We detected a giant X-ray flare from the RS-CVn type binary star UX Ari using MAXI on 2020 August 17 and started a series of NICER observations 89 minutes later. For a week, the entire duration of the flare was covered with 32 snapshot observations including the rising phase. The X-ray luminosity reached 2$\times$10$^{33}$ erg s$^{-1}$ and the entire energy release was $\sim 10^{38}$ erg in the 0.5--8.0~keV band. X-ray spectra characterized by continuum emission with lines of Fe XXV He$α$ and Fe XXVI Ly$α$ were obtained. We found that the temperature peaks before that of the flux, which suggests that the period of plasma formation in the magnetic flare loop was captured. Using the continuum information (temperature, flux, and their delay time), we estimated the flare loop size to be $\sim 3 \times 10^{11}$ cm and the peak electron density to be $\sim 4\times10^{10}$ cm$^{-3}$. Furthermore, using the line ratio of Fe XXV and Fe XXVI, we investigated any potential indications of deviation from collisional ionization equilibrium (CIE). The X-ray spectra were consistent with CIE plasma throughout the flare, but the possibility of an ionizing plasma away from CIE was not rejected in the flux rising phase.

astro-ph.SR

Ground test results of the electromagnetic interference for the x-ray microcalorimeter onboard XRISM

Electromagnetic interference (EMI) for low-temperature detectors is a serious concern in many missions. We investigate the EMI caused by the spacecraft components to the x-ray microcalorimeter of the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which is currently under development by an international collaboration and is planned to be launched in 2023. We focus on the EMI from (a) the low-frequency magnetic field generated by the magnetic torquers (MTQ) used for the spacecraft attitude control and (b) the radio-frequency (RF) electromagnetic field generated by the S and X band antennas used for communication between the spacecraft and the ground stations. We executed a series of ground tests both at the instrument and spacecraft levels using the flight-model hardware in 2021-2022 in a JAXA facility in Tsukuba. We also conducted electromagnetic simulations partially using the Fugaku high-performance computing facility. The MTQs were found to couple with the microcalorimeter, which we speculate through pick-ups of low-frequency magnetic field and further capacitive coupling. There is no evidence that the resultant energy resolution degradation is beyond the current allocation of noise budget. The RF communication system was found to leave no significant effect. We present the result of the tests and simulation in this article.

astro-ph.IM