Frequency domain multiplexing readout for large arrays of transition-edge sensors

We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on board the future Athena X-ray telescope. Using Ti/Au TES micro-calorimeters, high-Q LC filters and analog/digital electronics developed at SRON and low-noise two-stage SQUID amplifiers from VTT Finland, we demonstrated feasibility of our FDM readout technology, with the simultaneous readout of 37 pixels with an energy resolution at of 2.23 eV at an energy of 6 keV. We finally outline our plans for further scaling up and improving our technology.

astro-ph.IM

Susceptibility study of TES micro-calorimeters for X-ray spectroscopy under FDM readout

We present a characterization of the sensitivity of TES X-ray micro-calorimeters to environmental conditions under frequency-domain multiplexing (FDM) readout. In the FDM scheme, each TES in a readout chain is in series with a LC band-pass filter and AC biased with an independent carrier at MHz range. Using TES arrays, cold readout circuitry and warm electronics fabricated at SRON and SQUIDs produced at VTT Finland, we characterize the sensitivity of the detectors to bias voltage, bath temperature and magnetic field. We compare our results with the requirements for the Athena X-IFU instrument, showing the compliance of the measured sensitivities. We find in particular that FDM is intrinsically insensitive to the magnetic field because of TES design and AC readout.

astro-ph.IM

A test platform for the detection and readout chain for the Athena X-IFU

We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout, and will evolve over time to become more representative of the X-IFU mission baseline. The test bench yields critical feedback on subsystem designs and interfaces, in particular the warm readout electronics, and will provide an in-house detection system for continued testing and development of the warm readout electronics and for the validation of X-ray calibration sources. In this paper, we describe the test bench subsystems and design, characterization of the cryostat, and current status of the project.

astro-ph.IM

Josephson dynamical simulation using the electronic circuit simulator APLAC: a tutorial

Analysis Program for Linear Active Circuits (APLAC) is a general-purpose electronics circuit simulator, which has included a built-in model of the Josephson junction (JJ) since late 80's. It capabilities in simulating eg. noisy Superconducting Quantum Interference Devices (SQUIDs), Rapid Single Flux Quantum (RSFQ) logic circuits, or Superconducting Transition Edge Sensors (TESes) are relatively unknown within the superconducting electronics community. Here we give a brief step-to-step tutorial for APLAC users to unleash those capabilities.

cond-mat.supr-con

Two-stage SQUID amplifier with bias current re-use

We have designed and fabricated an integrated two-stage SQUID amplifier, requiring only one bias line and one flux setpoint line. From the biasing viewpoint the two stages are connected in series while from the signal propagation viewpoint the stages are cascaded. A proof-of principle demonstration at T = 4.2 K is presented.

physics.ins-det

Class-B cable-driving SQUID amplifier

We suggest a SQUID amplifier configuration with improved power efficiency, for applications where cooling budgets are limited, in particular superconducting detector array readouts in space observatories. The suggested two-SQUID configuration keeps one SQUID in a zero-voltage state during a half-cycle of the input while the other SQUID generates voltage. For the other half-cycle the roles of the SQUIDs are reversed. The circuit is an electrostatic dual of a transistor-based amplifier operating in class-B. A proof-of principle demonstration at T = 4.2 K is presented.

astro-ph.IM

Two SQUID amplifiers intended to alleviate the summing node inductance problem in multiplexed arrays of Transition Edge Sensors

Frequency Domain Multiplexed detector arrays constructed of superconducting Transition Edge Sensors in the current-summing configuration suffer from the finite impedance of the summing node which should ideally be zero. We suggest two circuits to alleviate the effect. The first circuit uses a capacitive resonant transformer to increase the voltages and decrease the currents of TES signals to overcome the parasitic inductance of the interconnections. On the SQUID chip impedance transform to the opposite direction takes place. The second circuit implements a power combiner having a better branch-to-branch isolation than a simple T-junction. Two SQUID devices have been designed and fabricated for a proof-of-principle demonstration of the circuits.

astro-ph.IM

Low-dissipating push-pull SQUID amplifier for TES detector readout

We suggest SQUID amplifier configuration intended for millikelvin refrigerators where cooling power is limited and hence high power efficiency is desirable. The configuration operates the SQUIDs in class-AB rather than the traditional class-A. A proof-of principle demonstration at T = 4.2 K is presented.

astro-ph.IM

Side-wall spacer passivated sub-um Josephson junction fabrication process

We present a structure and a fabrication method for superconducting tunnel junctions down to the dimensions of 200 nm using i-line UV lithography. The key element is a side-wall-passivating spacer structure (SWAPS) which is shaped for smooth crossline contacting and low parasitic capacitance. The SWAPS structure enables formation of junctions with dimensions at or below the lithography-limited linewidth. An additional benefit is avoiding the excessive use of amorphous dielectric materials which is favorable in sub-Kelvin microwave applications often plagued by nonlinear and lossy dielectrics. We apply the structure to niobium trilayer junctions, and provide characterization results yielding evidence on wafer-scale scalability, and critical current density tuning in the range of 0.1 -- 3.0 kA/cm$^2$. We discuss the applicability of the junction process in the context of different applications, such as, SQUID magnetometers and Josephson parametric amplifiers.

cond-mat.supr-con

Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a high quantum efficiency ($>$90 \%) and spectral resolution $ΔE$=2.5 eV $@$ 7 keV ($E/ΔE\sim$2800). FDM is currently the baseline readout system for the X-IFU instrument. Using high quality factor LC filters and room temperature electronics developed at SRON and low-noise two stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7 MHz in the single pixel read-out. We have also demonstrated for the first time an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES array (GSFC-A1). In this paper we report on the single pixel performance of these microcalorimeters under MHz AC bias, and further results of the performance of these pixels under FDM.

astro-ph.IM

Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena

The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.

astro-ph.IM

Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA

We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.

astro-ph.IM

Multiplexed readout demonstration of a TES-based detector array in a resistance locked loop

TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the instruments. In an effort to improve the properties of TES-based detectors, fixing the TES resistance in a resistance-locked loop (RLL) under optical loading has recently been proposed. Earlier theoretical work on this mode of operation has shown that the detector speed, linearity and dynamic range should improve with respect to voltage biased operation. This paper presents an experimental demonstration of multiplexed readout in this mode of operation in a TES-based detector array with noise equivalent power values (NEP) of $3.5\cdot 10^{-19} $W/$\sqrt{\mathrm{Hz}}$. The measured noise and dynamic properties of the detector in the RLL will be compared with the earlier modelling work. Furthermore, the practical implementation routes for future FDM systems for the readout of bolometer and microcalorimeter arrays will be discussed.

physics.ins-det

Operation of transition edge sensors in a resistance locked loop

We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal power. By combining a large negative electrothermal feedback with a load independent resistance, this approach can significantly linearise the response of the detector in the large signal limit. The electrothermal feedback is enhanced in comparison with the commonly applied voltage biasing, which further increases the speed of the detector. Furthermore, in frequency domain multiplexed (FDM) readout, the sinusoidal bias voltages for each TES can be generated cryogenically with the readout SQUIDs.

physics.ins-det