SearcharxivSearch

arXiv subjects

Miklós Koller

Publications and source records attributed to Miklós Koller.

5 recordsLinked to original sources

Morphology and actuation as inductive biases in robotic hand manipulation

Robotic hands vary widely in anatomical fidelity and mechanical complexity, and these structural choices influence the coordination of joint motions and the difficulty of controlling the system. A unified framework is presented in which the kinematic and actuation stages are analysed separately and in composition, through the conditioning of the task Jacobian, the actuation matrix, and their product. It is applied to two hands representing opposing design philosophies, the Shadow Dexterous Hand and the Anatomically Correct, Biomechatronic Hand, along four morphological aspects: joint axis geometry, actuator-to-DOF ratio, coupling architecture, and authority distribution. All parameters are derived from the hands' canonical digital representations. Anatomical fidelity carries no uniform advantage: oblique axes improve thumb conditioning but leave the long fingers worse conditioned than the orthogonal-axis design, while the branching tendon network improves the effective control mapping at every long finger and worsens it significantly at the thumb, where actuator authority is concentrated on thumb opposition. Predictions derived from these metrics are evaluated against reinforcement learning experiments using PPO, DDPG+HER, and TQC+HER, across three different tasks.

cs.RO

Tendon-based modelling, estimation and control for a simulated high-DoF anthropomorphic hand model

Tendon-driven anthropomorphic robotic hands often lack direct joint angle sensing, as the integration of joint encoders can compromise mechanical compactness and dexterity. This paper presents a computational method for estimating joint positions from measured tendon displacements and tensions. An efficient kinematic modeling framework for anthropomorphic hands is first introduced based on the Denavit-Hartenberg convention. Using a simplified tendon model, a system of nonlinear equations relating tendon states to joint positions is derived and solved via a nonlinear optimization approach. The estimated joint angles are then employed for closed-loop control through a Jacobian-based proportional-integral (PI) controller augmented with a feedforward term, enabling gesture tracking without direct joint sensing. The effectiveness and limitations of the proposed estimation and control framework are demonstrated in the MuJoCo simulation environment using the Anatomically Correct Biomechatronic Hand, featuring five degrees of freedom for each long finger and six degrees of freedom for the thumb.

cs.RO

The impact of tactile sensor configurations on grasp learning efficiency -- a comparative evaluation in simulation

Tactile sensors are breaking into the field of robotics to provide direct information related to contact surfaces, including contact events, slip events and even texture identification. These events are especially important for robotic hand designs, including prosthetics, as they can greatly improve grasp stability. Most presently published robotic hand designs, however, implement them in vastly different densities and layouts on the hand surface, often reserving the majority of the available space. We used simulations to evaluate 6 different tactile sensor configurations with different densities and layouts, based on their impact on reinforcement learning. Our two-setup system allows for robust results that are not dependent on the use of a given physics simulator, robotic hand model or machine learning algorithm. Our results show setup-specific, as well as generalized effects across the 6 sensorized simulations, and we identify one configuration as consistently yielding the best performance across both setups. These results could help future research aimed at robotic hand designs, including prostheses.

cs.RO

Standardized Evaluation of Fetal Phonocardiography Processing Methods

Motivation. Phonocardiography can give access to the fetal heart rate as well as direct heart sound data, and is entirely passive, using no radiation of any kind. Approach. We discuss the currently available methods for fetal heart sound detection and heart rate estimation and compare them using a common benchmarking platform and a pre-selected testing dataset. Compared to previous reviews, we evaluated the discussed methods in a standardized manner for a fair comparison. Our tests included tolerance-based detection accuracy, error rates for label insertions, deletions, and substitutions, and statistical measures for heart rate mean square error. Results. Based on our results, there is no definite best method that can achieve the highest scores in all of the tests, and simpler methods could perform comparably to more complex ones. The best model for first heart sound detection achieved 97.6% F1-score, 97.4% positive predictive value, and 12.2+-8.0 ms mean absolute error. In terms of second heart sound detection the best model had 91.4% F1-score, 91.3% positive predictive value, and 17.3+-12.2 ms mean absolute error. For fetal heart rate a 0.644 mean square error was achieved by the best method. Significance. Our main conclusion is that further standardization is required in fetal heart rate and heart sound detection method evaluation. The tests and algorithm implementations are openly available at: https://github.com/mulkr/standard-fpcg-evaluation.

eess.AS

pyPCG: A Python Toolbox Specialized for Phonocardiography Analysis

Phonocardiography has recently gained popularity in low-cost and remote monitoring, including passive fetal heart monitoring. Development for methods which analyse phonocardiographical data try to capitalize on this opportunity, and in recent years a multitude of such algorithms and models have been published. Although there is little to no standardization in these published algorithms and multiple parts of these models have to be reimplemented on a case-by-case basis. Datasets containing heart sound recordings also lack standardization in both data storage and labeling, especially in fetal phonocardiography. We are presenting a toolbox that can serve as a basis for a future standard framework for heart sound analysis. This toolbox contains some of the most widely used processing steps, and with these, complex analysis processes can be created. These functions can be individually tested. Due to the interdependence of the steps, we validated the current segmentation stage using a manually labeled fetal phonocardiogram dataset comprising 50 one-minute abdominal PCG recordings, which include 6,758 S1 and 6,729 S2 labels. Our results were compared to other common and available segmentation methods, peak detection with the Neurokit2 library, and the Hidden Semi-Markov Model by Springer et al. With a 30 ms tolerance our best model achieved a 97.1% F1 score and 10.8 +/- 7.9 ms mean absolute error for S1 detection. This detection accuracy outperformed all tested methods. With this a more accurate S2 detection method can be created as a multi-step process. After an accurate segmentation the extracted features should be representative of the selected segments, which allows for more accurate statistics or classification models. The toolbox contains functions for both feature extraction and statistics creation which are compatible with the previous steps.

eess.SP