Development and Commissioning of a Compact Cosmic Ray Muon Imaging Prototype

Due to the muon tomography's capability of imaging high Z materials, some potential applications have been reported on inspecting smuggled nuclear materials in customs. A compact Cosmic Ray Muons (CRM) imaging prototype, Lanzhou University Muon Imaging System (LUMIS), is comprehensively introduced in this paper including the structure design, assembly, data acquisition and analysis, detector performance test, and material imaging commissioning etc. Casted triangular prism plastic scintillators (PS) were coupled with Si-PMs for sensitive detector components in system. LUMIS's experimental results show that the detection efficiency of an individual detector layer is about 98%, the position resolution for vertical incident muons is 2.5 mm and the angle resolution is 8.73 mrad given a separation distance of 40.5 cm. Moreover, the image reconstruction software was developed based on the Point of Closest Approach (PoCA) to detect lead bricks as our target. The reconstructed images indicate that the profile of the lead bricks in the image is highly consistent with the target. Subsequently, the capability of LUMIS to distinguish different materials, such as Pb, Cu, Fe, and Al, was investigated as well. The lower limit of response time for rapidly alarming high-Z materials is also given and discussed. The successful development and commissioning of the LUMIS prototype have provided a new solution option in technology and craftsmanship for developing compact CRM imaging systems that can be used in many applications.

physics.ins-det

Optimization of Timepix3-based conventional Compton camera using electron track algorithm

The hybrid pixel detector Timepix3 allows the measurement of the time and energy deposition of an event simultaneously in each 55 $\mu$m pixel, which makes Timepix3 a promising approach for a compact Compton camera. However, the angular resolution of Compton camera based on this kind of detector with high pixel density is usually degraded in imaging of MeV gamma-ray sources, because the diffusion of energetic Compton electron or photoelectron could trigger many pixels and lead to an inaccurate measurement of interaction position. In this study, an electron track algorithm is used to reconstruct the electron track and determine the interaction point. An demonstrative experiment was carried out, showing that the effect of this algorithm was significant. The angular resolution measures of a single layer Compton camera based on Timepix3 was enhanced to 12 degrees (FWHM) in imaging of a Co-60 gamma source.

physics.ins-det

Diagnostics for ultrashort X-ray pulses using silicon trackers

The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of laser-plasma based X-ray pulse are not very high, especially in the range of several hundred keV. In this study, a new method based on electron tracks detection to measure the spectrum of laser-plasma produced X-ray pulses is proposed and demonstrated. Laser-plasma generated X-rays are scattered in a multi-pixel silicon tracker. Energies and scattering directions of Compton electrons can be extracted from the response of the detector, and then the spectrum of X-rays can be reconstructed. Simulations indicate that the energy resolution of this method is approximately 20% for X-rays from 200 to 550 keV for a silicon-on-insulator pixel detector with 12 $\rm \mu$m pixel pitch and 500 $\rm \mu$m depletion region thickness. The results of a proof-of-principle experiment based on a Timepix3 detector are also shown.