Publications and source records attributed to Mingyao Zhu.

3 recordsLinked to original sources

Planned, delivered and variable RBE dose difference analysis for a patient cohort with base-of-tongue cancer treated with IMPT

Background: To our knowledge, no tools have been installed in clinic for delivered and planned dose differences evaluation. This difference could be large for head and neck patients who suffer the most anatomy changes compared with other treatment sites due to long treatment courses and difficulty in eating. At the same time, variable RBE dose is an increasing concern for proton therapy. The constant RBE 1.1 is widely applied in clinics, however, the real RBE is larger than 1.1 especially at the end of beam range. How they are different and what the influence on plan evaluation are an interesting topic to investigate.

physics.med-ph

Applying voxel-based analysis to oropharyngeal cancer proton therapy patients: a correlation study on radiation-induced acute dysphagia

Background: Voxel-based analysis (VBA) is an analytic approach to evaluate correlations between local dose and the development of different toxicities. DVHs are used for toxicity prediction as well. Compared with DVH, no contours are required for VBA technique and results tell specific voxels that may be related to the toxicity instead of the whole contoured area. The VBA has been used on different cancer sites and for different toxicities. Most of these studies included patients treated with photon, all published studies were based on planned dose and VBA tools used were developed in house. In our study, patient cohort were treated with proton, our VBA tool was developed based on RayStation and doses fed to the VBA tool were delivered doses with constant and two variable RBE models.

physics.med-ph

Characterization of 250 MeV protons from Varian ProBeam pencil beam scanning system for FLASH radiation therapy

Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it is not typical to use 250 MeV protons for routine clinical treatments and as such 250 MeV may not have been characterized in the commissioning. In this study, we aim to characterize 250 MeV protons from Varian ProBeam system for FLASH RT as well as assess the ability of clinical monitoring ionization chamber (MIC) for FLASH-readiness. We measured data needed for beam commissioning: integral depth dose (IDD) curve, spot sigma, and absolute dose calibration. To evaluate MIC, we measured output as a function of beam current. To characterize a 250 MeV FLASH beam, we measured: (1) central axis DR as a function of current and spot spacing and arrangement, (2) for a fixed spot spacing, the maximum field size that still achieves FLASH DR (i.e., > 40 Gy/s), (3) DR reproducibility. All FLASH DR measurements were performed using ion chamber for the absolute dose and irradiation times were obtained from log files. We verified dose measurements using EBT-XD films and irradiation times using a fast, pixelated spectral detector. R90 and R80 from IDD were 37.58 and 37.69 cm, and spot sigma at isocenter were σx=3.336 and σy=3.332 mm, respectively. The absolute dose output was measured as 0.377 GyE*mm2/MU for the commissioning conditions. Output was stable for beam currents up to 15 nA, and it gradually increased to 12-fold for 115 nA. DR depended on beam current, spot spacing and arrangement and could be reproduced within 4.2% variations. Even though FLASH was achieved and the largest field size that delivers FLASH DR was determined as 35x35 mm2, current MIC has DR dependence and users should measure DR each time for their FLASH applications.

physics.med-ph