SearcharxivSearch

arXiv subjects

Mitchell L. R. Walker

Publications and source records attributed to Mitchell L. R. Walker.

2 recordsLinked to original sources

High resolution spatially extended 1D laser scattering diagnostics using volume Bragg grating notch filters

Laser light scattering systems with volume Bragg grating (VBG) filters, which act as a spectral/angular filter, have often been used as a point measurement technique with spatial resolution as low as a few hundred um defined by the beam waist. In this work, we demonstrate how VBG filters can be leveraged for spatially resolved measurements with several um resolution perpendicular to the laser propagation axis over a few mm along the beam propagation axis. The rejection ring, as determined by the angular acceptance criteria of the filter, is derived analytically, and the use of the ring for 1D laser line rejection is explained. For the example cases presented, having a focused probe beam waist with a diameter of ~150 um, the rejection ring can provide up to several mm length along the beam propagation axis for a 1D measurement, which is also tunable. Additionally, methods to further extend the measurable region are proposed and demonstrated; using a collimation lens with a different focal length or using multiple VBG filters. The latter case can minimize the scattering signal loss, without the trade-off of the solid angle. Such use of multiple VBGs is to extend the measurable region along the beam axis, which differs from the commonly known application of multiple filters to improve the suppression of elastic interferences. 1D rotational Raman and Thomson scattering measurements are carried out on pulsed and DC discharges to verify this method. The system features compactness, simple implementation, high throughput, and flexibility to accommodate various experimental conditions.

physics.optics

Electromagnetically Induced Distortion of a Fibrin Matrix with Embedded Microparticles

Blood clots occur in the human body when they are required to prevent bleeding. In pathological states such as diabetes and sickle cell disease, blood clots can also form undesirably due to hypercoagulable plasma conditions. With the continued effort in developing fibrin therapies for potential life-saving solutions, more mechanical modeling is needed to understand the properties of fibrin structures with inclusions. In this study, a fibrin matrix embedded with magnetic micro particles (MMPs) was subjected to a magnetic field to determine the magnitude of the required force to create plastic deformation within the fibrin clot. Using finite element (FE) analysis, we estimated the magnetic force from an electromagnet at a sample space located approximately 3 cm away from the coil center. This electromagnetic force coupled with gravity was applied on a fibrin mechanical system with MMPs to calculate the stresses and displacements. Using appropriate coil parameters, it was determined that application of a magnetic field of 730 A/m on the fibrin surface was necessary to achieve an electromagnetic force of 36 nN (to engender plastic deformation).

physics.bio-ph