SearcharxivSearch

arXiv subjects

Miu Tamamitsu

Publications and source records attributed to Miu Tamamitsu.

10 recordsLinked to original sources

Femtosecond-to-millisecond holographic imaging of laser ablation dynamics

Femtosecond laser ablation redistributes optically deposited energy across electronic, structural, mechanical, and thermal degrees of freedom over timescales from femtoseconds to milliseconds. However, these coupled processes are usually measured in separate temporal ranges and through different observables, limiting quantitative comparison between early transient dynamics, residual heating, and final morphology. Here we introduce pump-probe holographic imaging that reconstructs amplitude- and phase-resolved optical fields across this full temporal range under matched imaging conditions. Applied to deep-ultraviolet femtosecond ablation of BK7 glass, the method captures the transition from early excitation and removal-stage dynamics to residual substrate heating and permanent modification. Differential phase analysis isolates sub-nanosecond evolution of the transient ablating layer and microsecond residual heating after material removal. Above the ablation threshold, crater depth increases with fluence, whereas the residual thermal signal saturates, indicating that additional absorbed energy is preferentially partitioned into material removal and ablation-related processes rather than retained as substrate heat. These results identify fluence-dependent energy partitioning as a dynamical basis of low-heat-affected femtosecond processing and establish holographic imaging as a route to tracking laser-driven nonequilibrium material transformations.

physics.optics

Mid-infrared wide-field nanoscopy

Mid-infrared (MIR) spectroscopy is widely recognized as a powerful, non-distractive method for chemical analysis. However, its utility is constrained by a micrometer-scale spatial resolution imposed by the long-wavelength MIR diffraction limit. This limitation has been recently overcome by MIR photothermal (MIP) imaging, which detects photothermal effects induced in the vicinity of MIR absorbers using a visible-light microscope. Despite its promise, the full potential of its spatial resolving power has not been realized. Here, we present an optimal implementation of wide-field MIP imaging to achieve high spatial resolution. This is accomplished by employing single-objective synthetic-aperture quantitative phase imaging (SOSA-QPI) with synchronized sub-nanosecond MIR and visible light sources, effectively suppressing the resolution-degradation effect caused by photothermal heat diffusion. We demonstrate far-field MIR spectroscopic imaging with a spatial resolution limited by the visible diffraction, down to 125 nm, in the MIR region of 3.12-3.85 um (2,600-3,200 cm-1). This technique, through the use of a shorter visible wavelength and/or a higher objective numerical aperture, holds the potential to achieve a spatial resolution of less than 100 nm, thus paving the way for MIR wide-field nanoscopy.

physics.optics

Mid-infrared photothermal single-live-cell imaging beyond video rate

Advancement in mid-infrared (MIR) technology has led to promising biomedical applications of MIR spectroscopy, such as liquid biopsy or breath diagnosis. On the contrary, MIR microscopy has been rarely used for live biological samples in an aqueous environment due to the lack of spatial resolution and the large water absorption background. Recently, mid-infrared photothermal (MIP) imaging has proven to be applicable to 2D and 3D single-cell imaging with high spatial resolution inherited from visible light. However, the maximum measurement rate has been limited to several frames/s, limiting its range of use. Here, we develop a significantly-improved wide-field MIP quantitative phase microscope with two orders-of-magnitude higher signal-to-noise ratio than previous MIP imaging techniques and demonstrate single-live-cell imaging beyond video rate. We first derive optimal system design by numerically simulating thermal conduction following the photothermal effect. Then, we develop the designed system with a homemade nanosecond MIR optical parametric oscillator and a high full-well-capacity image sensor. Our high-speed and high-spatial-resolution MIR microscope has great potential to become a new tool for life science, in particular for single-live-cell analysis.

physics.optics

Label-free detection of Giardia lamblia cysts using a deep learning-enabled portable imaging flow cytometer

We report a field-portable and cost-effective imaging flow cytometer that uses deep learning to accurately detect Giardia lamblia cysts in water samples at a volumetric throughput of 100 mL/h. This flow cytometer uses lensfree color holographic imaging to capture and reconstruct phase and intensity images of microscopic objects in a continuously flowing sample, and automatically identifies Giardia Lamblia cysts in real-time without the use of any labels or fluorophores. The imaging flow cytometer is housed in an environmentally-sealed enclosure with dimensions of 19 cm x 19 cm x 16 cm and weighs 1.6 kg. We demonstrate that this portable imaging flow cytometer coupled to a laptop computer can detect and quantify, in real-time, low levels of Giardia contamination (e.g., <10 cysts per 50 mL) in both freshwater and seawater samples. The field-portable and label-free nature of this method has the potential to allow rapid and automated screening of drinking water supplies in resource limited settings in order to detect waterborne parasites and monitor the integrity of the filters used for water treatment.

eess.IV

Adaptive dynamic range shift (ADRIFT) quantitative phase imaging

Quantitative phase imaging (QPI) is often used for label-free single cell analysis with its high-contrast images of optical phase delay (OPD) map. Contrary to other imaging methods, sensitivity improvement has not been intensively explored because conventional QPI is sensitive enough to see surface roughness of a substrate which anyway restricts the measurable minimum OPD. However, emerging QPI techniques which utilize, for example, differential image analysis of consecutive temporal frames, such as mid-infrared photothermal QPI, mitigate the minimum OPD limit by decoupling the static OPD contribution and allow to measure much smaller OPD. Here, we propose and demonstrate super-sensitive QPI with expanded dynamic range. It is enabled by adaptive dynamic range shift with combination of wavefront shaping and dark-field QPI techniques. As a proof-of-concept demonstration, we show dynamic range expansion (sensitivity improvement) of QPI by a factor of 6.6 and its utility for improving sensitivity of mid-infrared photothermal QPI. This technique can also be applied for wide-field scattering imaging of dynamically changing nanoscale objects inside and outside a biological cell without losing global cellular morphological image information.

physics.optics

Label-free biochemical quantitative phase imaging with mid-infrared photothermal effect

Label-free optical imaging is valuable in biology and medicine with its non-destructive property and reduced optical and chemical damages. Quantitative phase (QPI) and molecular vibrational imaging (MVI) are the two most successful label-free methods, providing morphology and biochemistry, respectively, that have pioneered numerous applications along their independent technological maturity over the past few decades. However, the distinct label-free contrasts are inherently complementary and difficult to integrate due to the use of different light-matter interactions. Here, we present a unified imaging scheme that realizes simultaneous and in-situ acquisition of MV-fingerprint contrasts of single cells in the framework of QPI utilizing the mid-infrared photothermal effect. The fully label-free and robust integration of subcellular morphology and biochemistry would have important implications, especially for studying complex and fragile biological phenomena such as drug delivery, cellular diseases and stem cell development, where long-time observation of unperturbed cells are needed under low phototoxicity.

physics.bio-ph

Quantitative phase imaging with molecular vibrational sensitivity

Quantitative phase imaging (QPI) quantifies the sample-specific optical-phase-delay enabling objective studies of optically-transparent specimens such as biological samples, but lacks chemical sensitivity limiting its application to morphology-based diagnosis. We present wide-field molecular-vibrational microscopy realized in the framework of QPI utilizing mid-infrared photothermal effect. Our technique provides mid-infrared spectroscopic performance comparable to that of a conventional infrared spectrometer in the molecular fingerprint region of 1,450 - 1,600 cm-1 and realizes wide-field molecular imaging of silica-polystyrene beads mixture over 100 μm x 100 μm area at 1 frame per second with the spatial resolution of 430 nm and 2 - 3 orders of magnitude lower fluence of ~10 pJ/μm2 compared to other high-speed label-free molecular imaging methods, reducing photodamages to the sample. With a high-energy mid-infrared pulse source, our technique could enable high-speed, label-free, simultaneous and in-situ acquisition of quantitative morphology and molecular-vibrational contrast, providing new insights for studies of optically-transparent complex dynamics.

physics.optics

Molecular contrast on phase-contrast microscope

An optical microscope enables image-based findings and diagnosis on microscopic targets, which is indispensable in many scientific, industrial and medical settings. Majority of microscope users are accustomed to standard benchtop microscopes, but it fails to give molecular contrast of the specimen which otherwise requires expensive specialized instruments to measure, accompanied by chemical or optical damages to the sample and/or slow imaging speed. Here, we report on a simple optical instrument, comprising of a semiconductor amplitude-modulated mid-infrared quantum cascade laser, that is attached to a standard microscope to deliver the additional molecular contrast of the specimen on top of its conventional microscopic image. We attach this instrument, termed molecular-contrast unit, to a standard phase-contrast microscope, and demonstrate high-speed label-free molecular-contrast phase-contrast imaging of biological cells under low-power optical illumination. Our simple molecular-contrast unit can empower existing standard microscopes of various users, by delivering a convenient accessibility to the molecular world.

physics.optics

Spatial mapping and analysis of aerosols during a forest fire using computational mobile microscopy

Forest fires are a major source of particulate matter (PM) air pollution on a global scale. The composition and impact of PM are typically studied using only laboratory instruments and extrapolated to real fire events owing to a lack of analytical techniques suitable for field-settings. To address this and similar field test challenges, we developed a mobile-microscopy and machine-learning-based air quality monitoring platform called c-Air, which can perform air sampling and microscopic analysis of aerosols in an integrated portable device. We tested its performance for PM sizing and morphological analysis during a recent forest fire event in La Tuna Canyon Park by spatially mapping the PM. The result shows that with decreasing distance to the fire site, the PM concentration increases dramatically, especially for particles smaller than 2 microns. Image analysis from the c-Air portable device also shows that the increased PM is comparatively strongly absorbing and asymmetric, with an aspect ratio of 0.5-0.7. These PM features indicate that a major portion of the PM may be open-flame-combustion-generated element carbon soot-type particles. This initial small-scale experiment shows that c-Air has some potential for forest fire monitoring.

physics.ins-det

Comparison of Gini index and Tamura coefficient for holographic autofocusing based on the edge sparsity of the complex optical wavefront

The Sparsity of the Gradient (SoG) is a robust autofocusing criterion for holography, where the gradient modulus of the complex refocused hologram is calculated, on which a sparsity metric is applied. Here, we compare two different choices of sparsity metrics used in SoG, specifically, the Gini index (GI) and the Tamura coefficient (TC), for holographic autofocusing on dense/connected or sparse samples. We provide a theoretical analysis predicting that for uniformly distributed image data, TC and GI exhibit similar behavior, while for naturally sparse images containing few high-valued signal entries and many low-valued noisy background pixels, TC is more sensitive to distribution changes in the signal and more resistive to background noise. These predictions are also confirmed by experimental results using SoG-based holographic autofocusing on dense and connected samples (such as stained breast tissue sections) as well as highly sparse samples (such as isolated Giardia lamblia cysts). Through these experiments, we found that ToG and GoG offer almost identical autofocusing performance on dense and connected samples, whereas for naturally sparse samples, GoG should be calculated on a relatively small region of interest (ROI) closely surrounding the object, while ToG offers more flexibility in choosing a larger ROI containing more background pixels.

physics.optics