SearcharxivSearch

arXiv subjects

Mohammad Meraj Ghanbari

Publications and source records attributed to Mohammad Meraj Ghanbari.

4 recordsLinked to original sources

DustNet: A Wireless Network of Ultrasonic Neural Implants

Spatially distributed peripheral nerve recordings can be used to reconstruct motor intention and improve natural control of prosthetics However, many existing clinical solutions rely on percutaneous wires to access peripheral nerves; these sites are prone to infection and motion-induced electrode degradation, preventing chronic use. To address the need for fully wireless neural recording systems, this paper presents DustNet: a spatially-distributed network of ultrasonically-powered neural recording implants capable of supporting up to 8 simultaneously recording nodes over a single ultrasound link. To enable high throughput multi-implant communication, DustNet implements a time-division multiple-access (TDMA) protocol with up to 16-level amplitude modulation of the ultrasound backscatter that achieves up to 4x higher data rates than traditional on-off keying methods. Each neural implant consists of a 0.7x0.7x0.7 mm$^3$ piezoceramic transducer, a 100 nF off-chip capacitor, and an IC mounted on a flexible PCB. The implant IC was fabricated in a 28nm CMOS process and occupies an area of 0.43 mm$^2$. System functionality was verified at 90mm depth in oil, achieving a maximum measured data rate of 200 kb/s at 2 MHz ultrasound carrier frequency, with each implant transmitting uplink data at 50 kb/s and dissipating just 7 $μ$W; the system is demonstrated to support up to 400 kb/s total data rate over the same link.

eess.SY

Phased array beamforming methods for powering biomedical ultrasonic implants

Millimeter-scale implants using ultrasound for power and communication have been proposed for a range of deep-tissue applications, including neural recording and stimulation. However, published implementations have shown high sensitivity to misalignment with the external ultrasound transducer. Ultrasonic beamforming using a phased array to these implants can improve tolerance to misalignment, reduce implant volume, and allow multiple implants to be operated simultaneously in different locations. This paper details the design of a custom planar phased array ultrasound system, which is capable of steering and focusing ultrasound power within a 3D volume. Analysis and simulation is performed to determine the choice of array element pitch, with special attention given to maximizing the power available at the implant while meeting FDA limits for diagnostic ultrasound. Time reversal is proposed as a computationally simple approach to beamforming that is robust despite scattering and inhomogeneity of the acoustic medium. This technique is demonstrated both in active drive and pulse-echo modes, and it is experimentally compared with other beamforming techniques by measuring energy transfer efficiency. Simultaneous power delivery to multiple implants is also demonstrated.

eess.SY

Optimizing Volumetric Efficiency and Modeling Backscatter Communication in Biosensing Ultrasonic Implants

Ultrasonic backscatter communication has gained popularity in recent years with the advent of deep-tissue sub-mm scale biosensing implants in which piezoceramic (piezo) resonators are used as acoustic antennas. Miniaturization is a key design goal for such implants to reduce tissue displacement and enable minimally invasive implantation techniques. Here, we provide a systematic design approach for the implant piezo geometry and operation frequency to minimize the overall volume of the implant. Moreover, a critical design aspect of an ultrasonic backscatter communication link is the response of the piezo acoustic reflection coefficient $Γ$ with respect to the variable shunt impedance, $Z_E$, of the implant uplink modulator. Due to the complexity of the piezo governing equations and multi-domain, electro-acoustical nature of the piezo, $Γ(Z_E)$ has often been characterized numerically and the implant uplink modulator has been designed empirically resulting in sub-optimal performance in terms of data rate and linearity. Here, we present a SPICE friendly end-to-end equivalent circuit model of the channel as a piezo-IC co-simulation tool that incorporates inherent path losses present in a typical ultrasonic backscatter channel. The circuit model is then used to simulate the channel transient response in a common CAD tool. To provide further insight into the channel response, we present experimentally validated closed form expressions for $Γ(Z_E)$ under various boundary conditions. These expressions couple $Γ$ to the commonly used Thevenin equivalent circuit model of the piezo, facilitating systematic design and synthesis of ultrasonic backscatter uplink modulators

physics.app-ph

A Sub-mm$^3$ Ultrasonic Free-floating Implant for Multi-mote Neural Recording

A 0.8 mm$^3$ wireless, ultrasonically powered, free-floating neural recording implant is presented. The device is comprised only of a 0.25 mm$^2$ recording IC and a single piezoceramic resonator that is used for both power harvesting and data transmission. Uplink data transmission is performed by analog amplitude modulation of the ultrasound echo. Using a 1.78 MHz main carrier, >35 kbps/mote equivalent uplink data rate is achieved. A technique to linearize the echo amplitude modulation is introduced, resulting in <1.2\% static nonlinearity of the received signal over a $\pm$10 mV input range. The IC dissipates 37.7 $μ$W, while the neural recording front-end consumes 4 $μ$W and achieves a noise floor of 5.3 $μ$V$_{rms}$ in a 5 kHz bandwidth. This work improves sub-mm recording mote depth by >2.5x, resulting in the highest measured depth/volume ratio by $\sim$3x. Orthogonal subcarrier modulation enables simultaneous operation of multiple implants, using a single-element ultrasound external transducer. Dual-mote simultaneous power up and data transmission is demonstrated at a rate of 7 kS/s at the depth of 50 mm.

eess.SP