Searcharxiv⌕ Search

arXiv subjects

Mohammad Rezaee

Publications and source records attributed to Mohammad Rezaee.

2 recordsLinked to original sources

Causal Multiscale Modeling of Ocular FLASH Electroretinography: Model Development, Experimental Fitting, and Spin-Glass--Percolation Predictions

Purpose: To develop a causal multiscale model of retinal electroretinography (ERG) after ocular ultrahigh-dose-rate (FLASH) and conventional-dose-rate (CONV) irradiation, evaluate the framework against published ocular ERG data, and derive prospective dose-response predictions for future validation. Methods: The retina was coarse-grained into $N=200$ functional modules. Local rate equations were formulated as Hodgkin--Huxley-inspired conductance-balance/RC reductions of retinal ion-channel and synaptic pathways. Radiation generated an injury field that altered phototransduction, a-wave and b-wave dynamics and, in the network extension, inter-module coupling and bond survival. A reduced amplitude benchmark and nested M0/M1/M2 causal models were evaluated. Results: The reduced benchmark achieved $R^2=0.9721$ and RMSE $=11.94~μ$V. M0, M1, and M2 yielded $R^2=0.8546$, 0.8559, and 0.8560, respectively, indicating limited independent identifiability of the network terms from amplitude data alone. Under an exploratory 50\% retained-gain criterion, the reduced benchmark predicted a-wave preservation thresholds of 28.6 Gy for FLASH and 23.7 Gy for CONV, and b-wave thresholds of 29.2 Gy and 24.1 Gy, respectively, corresponding to a model-based functional dose-modifying factor (DMF) of 1.21. Conclusion: The ERG amplitude data support the causal radiation-injury-to-ERG framework, while additional observables will be needed to distinguish the predicted collective-network contributions. The model also provides quantitative dose targets for prospective studies of the FLASH retinal-preservation window and a framework for testing how local retinal injury may propagate into collective dysfunction.

physics.med-ph↗

Dosimetric Quantification of a Commercial Dual-Tube kV X-Ray System for Preclinical FLASH Research

A kV dual tube system has been disseminated as a commercial research platform for preclinical FLASH radiotherapy (RT). Because the tubes are arranged in a parallel opposed geometry, both output symmetry and time resolved tube synchronization are critical for achieving sufficiently high dose rates (DR) and reproducible study results. We quantified tube output asymmetry observed in depth dose measurements as well as tube synchronization and evaluated their impact on FLASH studies. The dual-tube system defines dose per pulse as the combined single pulse output from both tubes, with DR given by dose per pulse/pulse length. 3D dose distributions were reconstructed from film measurements to assess the impact of output discrepancies. Pulse synchronization between tubes was characterized using a scintillator with 1 ms resolution. We showed >20% discrepancies in output at nominally equal mA/ms settings. After we compensated such discrepancy by decreasing the current of the tube with higher output, the inter tube output difference was reduced to <1%, restoring symmetrical depth dose. We further simulated an in vivo intestinal irradiation in which naive tube settings resulted in >22% of the organ volume receiving >102% of the prescribed dose, compared with <7% when output compensation was applied. We identified a 10.2 +/- 7.0ms synchronization jitter between tubes, which disproportionately impacts the DR at low dose-per-pulse settings, particularly relevant for fractionated studies. Corresponding quality assurance (QA) was designed to monitor tube synchronization over time. We quantified the dosimetric impact of asymmetric output and synchronization and demonstrated implications for preclinical studies. The proposed methodology and QA would mitigate and monitor these effects, ensuring study reproducibility.

physics.med-ph↗