Searcharxiv⌕ Search

arXiv subjects

Mohammadreza Soltany Sadrabadi

Publications and source records attributed to Mohammadreza Soltany Sadrabadi.

2 recordsLinked to original sources

DSU-Net: An Attention-Enhanced Dense Skip U-Net for Breast Lesion Segmentation in Mammographic Images

Breast cancer remains one of the leading causes of cancer-related mortality among women worldwide, making early detection essential for effective treatment. Mammography is the primary screening modality; however, accurate delineation of suspicious lesions remains challenging and subject to inter-observer variability. Automated segmentation methods can assist radiologists by providing consistent and efficient lesion localization. This study presents DSU-Net, an attention-enhanced Dense Skip U-Net architecture for automated breast lesion segmentation in mammographic images. The proposed framework integrates dense skip connections and attention mechanisms to improve feature propagation, preserve spatial information, and enhance lesion boundary delineation. Experiments were conducted using the Curated Breast Imaging Subset of the Digital Database for Screening Mammography (CBIS-DDSM). To address severe foreground-background imbalance, a composite loss function combining Dice loss, focal loss, and binary cross-entropy loss was employed during training. The proposed model achieved a Dice Similarity Coefficient of 0.9421, an Intersection over Union of 0.8905, an accuracy of 0.9711, and an AUC-ROC of 0.9878 on the validation dataset. Qualitative evaluation demonstrated accurate delineation of lesions with varying sizes and morphologies, while quantitative results confirmed robust discrimination between lesion and background regions. These findings demonstrate that DSU-Net provides accurate and reliable breast lesion segmentation in mammographic images and highlights the potential of attention-guided deep learning for computer-aided breast cancer screening and diagnosis.

q-bio.QM↗

Hemodynamic Overlap Between Ruptured and Unruptured Cerebral Aneurysms Using an In-House Parallel C++ Finite Element Solver

Cerebral aneurysm rupture has long been associated with abnormal hemodynamic conditions, particularly wall shear stress (WSS)-related flow behavior. Although aneurysm rupture is widely recognized as a multifactorial phenomenon involving complex interactions between geometry, flow structures, and multiple hemodynamic quantities, WSS-based parameters remain among the most commonly reported metrics in computational aneurysm studies. In the present study, computational fluid dynamics simulations were performed using an in-house parallel C++ finite element solver to investigate velocity streamlines, wall shear stress (WSS), and time-averaged wall shear stress (TAWSS) in patient-specific ruptured and unruptured cerebral aneurysm models. The computed flow fields demonstrated substantial hemodynamic overlap between the two groups, with elevated WSS and TAWSS regions observed in both ruptured and unruptured aneurysms. Similar high-velocity inflow structures and localized shear concentration patterns were identified across different cases, demonstrating that elevated shear-related magnitudes can be present in aneurysms with different rupture statuses. The results show that comparable WSS- and TAWSS-based hemodynamic characteristics may exist in aneurysms with different clinical outcomes, emphasizing the complexity and case-dependent nature of cerebral aneurysm hemodynamics. Rather than proposing rupture prediction criteria, the present study provides a focused computational assessment of hemodynamic similarities between ruptured and unruptured aneurysms and highlights the importance of careful interpretation of isolated WSS- and TAWSS-based analyses in rupture assessment.

physics.med-ph↗