Performance of Differential Protection Applied to Collector Cables of Offshore Wind Farms with MMC-HVDC Transmission

The ongoing global transition towards low-carbon energy has propelled the integration of offshore wind farms, which, when combined with Modular Multilevel Converter-based High-Voltage Direct Current (MMC-HVDC) transmission, present unique challenges for power system protection. In collector cables connecting wind turbines to offshore MMC, both ends are supplied by Inverter-Based Resources (IBRs), which modify the magnitude and characteristics of fault currents. In this context, this paper investigates the limitations of conventional differential protection schemes under such conditions and compares them with enhanced strategies that account for sequence components. Using electromagnetic transient simulations of a representative offshore wind farm modeled in PSCAD/EMTDC software, internal and external fault scenarios are assessed, varying fault types and resistances. The comparative evaluation provides insights into the sensitivity and selectivity of differential protection and guides a deeper conceptual understanding of the evolving protection challenges inherent to future converter-dominated grids.

eess.SY↗

Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks

This paper investigates how grid-forming (GFM) and grid-following (GFL) control strategies in inverter-based resources (IBRs) influence line distance and differential protection in converter-dominated transmission systems. A modified IEEE 39-bus system is evaluated with GFM and GFL units equipped with low-voltage ride-through logic, current limiting, and positive- or negative-sequence prioritization. Distance protection is implemented with a mho characteristic, while line differential protection uses an alpha-plane approach. Results show that phase-to-ground loops in distance protection can substantially overestimate the fault location near the Zone-1 reach. For line differential protection, external faults may cause the operating point to briefly enter the trip region of the alpha-plane, even for the healthy-phase in ABG faults under GFL control and during the initial moments of the fault, demanding strong external security measures. These findings highlight that modern converter controls, together with current limitation and sequence-current prioritization, can compromise the reliability and security of traditional protection schemes.

eess.SY↗