SearcharxivSearch

arXiv subjects

Moritz Mehmet

Publications and source records attributed to Moritz Mehmet.

At least 19 recordsLinked to original sources

A compact low-frequency optomechanical triaxial inertial sensor

Triaxial optomechanical accelerometers offer compact, ground-testable alternatives to electrostatic sensors for satellite geodesy, seismometry, and various other applications. We demonstrate a low-CSWaP triaxial sensor using monolithic fused-silica resonators with dual heterodyne interferometric readout. The X axis reaches a 60~pico-g/$\sqrt{\mathrm{Hz}}$ readout noise floor, and the in-plane axes resolve ambient seismic ground motion in agreement with a co-located commercial seismometer from 4~mHz to 8~Hz. The Z axis exhibits higher noise under $1g$ loading due to gravity-induced geometric stiffening (44.45~Hz versus 11.07~Hz in a 0g-equivalent configuration), with measurements indicating in-orbit performance on par with the in-plane sensors. These results support the feasibility of triaxial optomechanical accelerometry for space missions and ground-based applications.

physics.optics

Parasitic Interference in Heterodyne Interferometers: Modeling, Characterization, and Mitigation

Parasitic interference is a common limitation in laser interferometers, arising from unwanted beams that corrupt the phase measurement and degrade displacement sensitivity. In this work, we present a unified framework for the characterization and mitigation of parasitic interference in heterodyne interferometers. Parasitic beams are classified into two types based on the orientation of their corresponding phase vectors, and their noise contribution is modeled as a function of polarization, relative amplitude, and phase of the parasitic beam. Central to this framework is the concept of coupling coefficients, which quantify the interferometer's susceptibility to parasitic interference and can be readily computed using Jones calculus for any optical configuration. The two types of parasitic interference motivate distinct mitigation strategies: differential interferometry and balanced detection, complemented by polarization control and high-quality beam splitters. The models and mitigation strategies are validated experimentally in both a simplified Mach-Zehnder interferometer and a differential interferometer used for optomechanical inertial sensing, demonstrating reductions in parasitic phase noise by up to four orders of magnitude and achieving sub-picometer displacement sensitivity at frequencies as low as 9 mHz under ambient atmospheric pressure.

physics.optics

Demonstration of $\bf3.5\times10^{-13}$ laser frequency stability at 1000 s using an iodine-filled hollow-core fiber photonic microcell

We present a laser frequency stabilization system based on an iodine-filled hollow-core photonic microcell (PMC), which is a sealed version of a hollow-core photonic crystal fiber (HC-PCF). A 532 nm laser is locked to the a1 component of the R(56) 32-0 transition of molecular iodine in the fiber cell, and its frequency stability is compared to that of the same component in a free-space iodine cell. Noise analysis reveals that the system is limited by parasitic beams that interfere with the beam of interest and degrade the error signal. We have identified and characterized three types of parasitic interference and designed suppression methods for each. After applying these suppression methods, the frequency stability improved by more than an order of magnitude. The system achieves fractional frequency stability of $3.5\times10^{-13}$ for integration times around 1000 s. To our knowledge, this represents the best frequency stability achieved using a gas-filled hollow-core photonic crystal fiber frequency reference.

physics.optics

A Broadband Squeezed Light Source for Table-Top Interferometry

We report on the characterisation of one of two broadband squeezed light sources developed for the Quantum Enhanced Space-Time (QUEST) experiment, using balanced homodyne detection. QUEST consists of a pair of co-located, table-top, power-recycled Michelson interferometers designed to probe stationary space-time fluctuations. The interferometers are designed to be shot-noise limited in the frequency range from 1 to 200 MHz, and squeezed light will be employed with the goal to reduce the shot noise by 6 dB at frequencies inside the linewidth of the optical parametric amplifier (OPA). We directly observed up to 6.8 dB of squeezing and maintained at least 3 dB of squeezing across the full 100 MHz measurement bandwidth. After accounting for the dark noise contribution, the inferred squeezing level increased to 8.6 dB. Our squeezed light source is based on a hemilithic OPA with a 43.6 mm round-trip optical length and a linewidth of 138 MHz, making it the broadest-linewidth device to date among those suitable for long-term operation.

physics.optics

Detection of 15 dB Squeezed States of Light and their Application for the Absolute Calibration of Photoelectric Quantum Efficiency

Squeezed states of light belong to the most prominent nonclassical resources. They have compelling applications in metrology, which has been demonstrated by their routine exploitation for improving the sensitivity of a gravitational-wave detector since 2010. Here, we report on the direct measurement of 15 dB squeezed vacuum states of light and their application to calibrate the quantum efficiency of photoelectric detection. The object of calibration is a customized InGaAs positive intrinsic negative (p-i-n) photodiode optimized for high external quantum efficiency. The calibration yields a value of 99.5% with a 0.5% (k = 2) uncertainty for a photon flux of the order 10^17/s at a wavelength of 1064 nm. The calibration neither requires any standard nor knowledge of the incident light power and thus represents a valuable application of squeezed states of light in quantum metrology.

quant-ph

Single-Element Dual-Interferometer for Precision Inertial Sensing: Sub-picometer Structural Stability and Performance as a Reference for Laser Frequency Stabilization

To reach sub-picometer sensitivity in the millihertz range, displacement sensors based on laser interferometry require suppression of laser-frequency noise by several orders of magnitude. Many optical frequency stabilization methods exist with varying levels of complexity, size, and performance. In this paper, we describe the performance of a compact Mach-Zehnder interferometer based on a monolithic optic. The setup consists of a commercial fiber injector, a custom-designed pentaprism used to split and recombine the laser beam, and two photoreceivers placed at the complementary output ports of the interferometer. The structural stability of the prism is transferred to the laser frequency via amplification, integration, and feedback of the balanced-detection signal, achieving a fractional frequency instability better than 6 parts in $10^{13}$, corresponding to an interferometer pathlength stability better than $10^{-12}$ m$/\sqrt{\mathrm{Hz}}$.

physics.optics

$2\cdot 10^{-13}$ fractional laser frequency stability with a 7-cm unequal-arm Mach-Zehnder interferometer

To achieve sub-picometer sensitivities in the millihertz band, laser interferometric inertial sensors rely on some form of reduction of the laser frequency noise, typically by locking the laser to a stable frequency reference, such as the narrow-linewidth resonance of an ultra-stable optical cavity or an atomic or molecular transition. In this paper we report on a compact laser frequency stabilization technique based on an unequal-arm Mach-Zehnder interferometer that is sub-nanometer stable at $10\,μ$Hz, sub-picometer at $0.5\,$mHz, and reaches a noise floor of $7\,\mathrm{fm}/\!\sqrt{\mathrm{Hz}}$ at 1 Hz. The interferometer is used in conjunction with a DC servo to stabilize the frequency of a laser down to a fractional instability below $4 \times 10^{-13}$ at averaging times from 0.1 to 100 seconds. The technique offers a wide operating range, does not rely on complex lock acquisition procedures, and can be readily integrated as part of the optical bench in future gravity missions.

physics.optics

Characterization and evasion of backscattered light in the squeezed-light enhanced gravitational wave interferometer GEO 600

Squeezed light is injected into the dark port of gravitational wave interferometers, in order to reduce the quantum noise. A fraction of the interferometer output light can reach the OPO due to sub-optimal isolation of the squeezing injection path. This backscattered light interacts with squeezed light generation process, introducing additional measurement noise. We present a theoretical description of the noise coupling mechanism. We propose a control scheme to achieve a de-amplification of the backscattered light inside the OPO with a consequent reduction of the noise caused by it. The scheme was implemented at the GEO 600 detector and has proven to be crucial in maintaining a good level of quantum noise reduction of the interferometer for high parametric gain of the OPO. In particular, the mitigation of the backscattered light noise helped in reaching 6dB of quantum noise reduction [Phys. Rev. Lett. 126, 041102 (2021)]. The impact of backscattered-light-induced noise on the squeezing performance is phenomenologically equivalent to increased phase noise of the squeezing angle control. The results discussed in this paper provide a way for a more accurate estimation of the residual phase noise of the squeezed light field.

physics.optics

Direct limits for scalar field dark matter from a gravitational-wave detector

The nature of dark matter remains unknown to date; several candidate particles are being considered in a dynamically changing research landscape. Scalar field dark matter is a prominent option that is being explored with precision instruments, such as atomic clocks and optical cavities. Here we report on the first direct search for scalar field dark matter utilising a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits for the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beamsplitter of the GEO$\,$600 interferometer. The new constraints improve upon bounds from previous direct searches by more than six orders of magnitude, and are in some cases more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be probed or constrained with direct searches using gravitational-wave detectors, and highlights the potential of quantum-enhanced interferometry for dark matter detection.

gr-qc

Single-element dual-interferometer for precision inertial sensing

Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the tools of choice for such measurement schemes. Using sinusoidal phase modulation homodyne interferometry allows a drastic reduction of the complexity of the optical setup, a key limitation of multi-channel interferometry. By shifting the complexity of the setup to the signal processing stage, these methods enable devices with a size and weight not feasible using conventional techniques. In this paper we present the design of a novel sensor topology based on deep frequency modulation interferometry: the self-referenced single-element dual-interferometer (SEDI) inertial sensor, which takes simplification one step further by accommodating two interferometers in one optic. Using a combination of computer models and analytical methods we show that an inertial sensor with sub-picometer precision for frequencies above 10 mHz, in a package of a few cubic inches, seems feasible with our approach. Moreover we show that by combining two of these devices it is possible to reach sub-picometer precision down to 2 mHz. In combination with the given compactness, this makes the SEDI sensor a promising approach for applications in high precision inertial sensing for both next-generation space-based gravity missions employing drag-free control, and ground-based experiments employing inertial isolation systems with optical readout.

physics.ins-det

First demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory

Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO\,600 observatory and demonstrate for the first time a reduction of quantum noise up to $6.03 \pm 0.02$ dB in a kilometer-scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of four. Achieving this milestone, a key goal for the upgrades of the advanced detectors, required a better understanding of the noise sources and losses, and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight towards the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.

physics.ins-det

Compact multi-fringe interferometry with sub-picometer precision

Deep frequency modulation interferometry combines optical minimalism with multi-fringe readout. Precision however is key for applications such as optical gradiometers for satellite geodesy or as dimensional sensor for ground-based gravity experiments. We present a single-component interferometer smaller than a cubic inch. Two of these are compared to each other to demonstrate tilt and displacement measurements with a precision of less than $20\,\mathrm{nrad}/\sqrt{\mathrm{Hz}}$ and $1\,\mathrm{pm}/\sqrt{\mathrm{Hz}}$ at frequencies below $1\,\mathrm{Hz}$.

astro-ph.IM

Continuous-wave squeezed states of light via 'up-down' self-phase modulation

Continuous-wave (cw) squeezed states of light have applications in sensing, metrology and secure communication. In recent decades their efficient generation has been based on parametric down-conversion, which requires pumping by externally generated pump light of twice the optical frequency. Currently, there is immense effort in miniaturizing squeezed-light sources for chip-integration. Designs that require just a single input wavelength are favored since they offer an easier realization. Here we report the first observation of cw squeezed states generated by self-phase modulation caused by subsequent up and down conversions. The wavelengths of input light and of balanced homodyne detection are identical, and 1550 nm in our case. At sideband frequencies around 1.075 GHz, a nonclassical noise reduction of (2.4 +/- 0.1) dB is observed. The setup uses a second-order nonlinear crystal, but no externally generated light of twice the frequency. Our experiment is not miniaturized, but might open a route towards simplified chip-integrated realizations.

quant-ph

Laser-Frequency Stabilization via a Quasimonolithic Mach-Zehnder Interferometer with Arms of Unequal Length and Balanced dc Readout

Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to achieve picometer level sensitivities in the 0.1 mHz to 1 Hz regime, where laser frequency noise is usually high and couples into the measurement phase via arm-length mismatches in the interferometers. Here we describe the results achieved by frequency stabilising an external cavity diode laser to a quasi-monolithic unequal arm-length Mach-Zehnder interferometer read out at mid-fringe via balanced detection. We find this stabilization scheme to be an elegant solution combining a minimal number of optical components, no additional laser modulations and relatively low frequency noise levels. The Mach-Zehnder interferometer has been designed and constructed to minimize the influence of thermal couplings and to reduce undesired stray light using the optical simulation tool ifocad. We achieve frequency-noise levels below 100 Hz/$\sqrt{\textrm{Hz}}$ at 1 Hz and are able to demonstrate the LISA frequency prestabilization requirement of 300 Hz/$\sqrt{\textrm{Hz}}$ down to frequencies of 100 mHz by beating the stabilized laser with an iodine-locked reference.

physics.ins-det

Gaussian entanglement distribution with gigahertz bandwidth

The distribution of entanglement with Gaussian statistic can be used to generate a mathematically-proven secure key for quantum cryptography. The distributed secret key rate is limited by the {entanglement strength, the entanglement bandwidth and the bandwidth of the photo-electric detectors}. The development of a source for strongly, bi-partite entangled light with high bandwidth promises an increased measurement speed and a linear boost in the secure data rate. Here, we present the experimental realization of a Gaussian entanglement source with a bandwidth of more than 1.25\,GHz. The entanglement spectrum was measured with balanced homodyne detectors and was quantified via the inseparability criterion introduced by Duan and coworkers with a critical value of 4 below which entanglement is certified. Our measurements yielded an inseparability value of about 1.8 at a frequency of 300\,MHz to about 2.8 at 1.2\,GHz extending further to about 3.1 at 1.48\,GHz. In the experiment we used two 2.6\,mm long monolithic periodically poled potassium titanyl phosphate (PPKTP) resonators to generate two squeezed fields at the telecommunication wavelength of 1550\,nm. Our result proves the possibility of generating and detecting strong continuous-variable entanglement with high speed.

quant-ph

High-bandwidth squeezed light at 1550 nm from a compact monolithic PPKTP cavity

We report the generation of squeezed vacuum states of light at 1550 nm with a broadband quantum noise reduction of up to 4.8 dB ranging from 5 MHz to 1.2 GHz sideband frequency. We used a custom-designed 2.6 mm long biconvex periodically-poled potassium titanyl phosphate (PPKTP) crystal. It featured reflectively coated end surfaces, 2.26 GHz of linewidth and generated the squeezing via optical parametric amplification. Two homodyne detectors with different quantum efficiencies and bandwidths were used to characterize the non-classical noise suppression. We measured squeezing values of up to 4.8 dB from 5 to 100 MHz and up to 3 dB from 100 MHz to 1.2 GHz. The squeezed vacuum measurements were limited by detection loss. We propose an improved detection scheme to measure up to 10 dB squeezing over 1 GHz. Our results of GHz bandwidth squeezed light generation provide new prospects for high-speed quantum key distribution.

quant-ph

Continuous-wave non-classical light with GHz squeezing bandwidth

Squeezed states can be employed for entanglement-based continuous-variable quantum key distribution, where the secure key rate is proportional to the bandwidth of the squeezing. We produced a non-classical continuous-wave laser field at the telecommunication wavelength of 1550 nm, which showed squeezing over a bandwidth of more than 2 GHz. The experimental setup used parametric down-conversion via a periodically poled potassium titanyl phosphate crystal (PPKTP). We did not use any resonant enhancement for the funda- mental wavelength, which should in principle allow a production of squeezed light over the full phase-matching bandwidth of several nanometers. We measured the squeezing to be up to 0.3 dB below the vacuum noise from 50 MHz to 2 GHz limited by the measuring bandwidth of the homodyne detector. The squeezing strength was possibly limited by thermal lensing inside the non-linear crystal.

quant-ph

Squeezed light at 1550 nm with a quantum noise reduction of 12.3 dB

Continuous-wave squeezed states of light at the wavelength of 1550 nm have recently been demonstrated, but so far the obtained factors of noise suppression still lag behind today's best squeezing values demonstrated at 1064 nm. Here we report on the realization of a half-monolithic nonlinear resonator based on periodically-poled potassium titanyl phosphate which enabled the direct detection of up to 12.3 dB of squeezing at 5 MHz. Squeezing was observed down to a frequency of 2 kHz which is well within the detection band of gravitational wave interferometers. Our results suggest that a long-term stable 1550 nm squeezed light source can be realized with strong squeezing covering the entire detection band of a 3rd generation gravitational-wave detector such as the Einstein Telescope.

quant-ph