SearcharxivSearch

arXiv subjects

Muhammad Abubakar

Publications and source records attributed to Muhammad Abubakar.

3 recordsLinked to original sources

Smart Switching and Control of a Distributed Generator Synchronized With National Grid

Distributed generation is widely being utilized, so the basic theme of this research is to have a hands-on experience to synchronize a Distributed Energy Resource (DER) to the Mains Grid. A control algorithm is implemented for energy supply from both sources i.e. DER and Mains Grid, according to the cost and availability of each source. When load changes, so that the synchronization does not lose. LabVIEW software is used for the implementation of the desired system. Validation is done by experimenting in the lab. In order to keep the system stable, the algorithm has been developed to shift the load from one bus to the other depending upon the load requirements. The project is a test bed and can be used for further experimentation and prove helpful in developing a basic understanding of Smart Switching using LabVIEW.

eess.SY

Design and Implementation of an Automatic Synchronizing and Protection Relay through Power-Hardware-in-the-Loop (PHIL) Simulation

This paper focuses on the design and implementation of an automatic synchronizing and protection relay to automate the synchronization process of a Distributed Energy Resource (DER) to the Main Grid. The proposed design utilize a cost-effective data acquisition using arduino in combination with LabVIEW software to implement the multi-purpose synchronizing relay. The proposed synchronizing relay is capable of synchronizing a Distributed Generator (DG) to the power grid from black-start and fulfills the requirements imposed by the utility. The synchronizing relay is implemented through voltage and frequency control of an actual lab-scale synchronous generator. In the synchronization process, frequency synchronization is done using speed control of the stepper motor as prime mover and voltage synchronization is accomplished using Excitation Control module through Power-Hardware-in-the-Loop (PHIL) simulation. In grid-connected mode, active and reactive power controls and protection schemes for the synchronous generator have also been implemented. The proposed multi-function relay has been deployed and tested on a lab-scale test bed to validate the proposed design and functionality.

eess.SY

An Accurate Fault Location Algorithm for Meshed Power Networks Utilizing Hybrid Sparse Voltage and Current Measurements

This paper proposes an accurate fault location algorithm technique based on hybrid synchronized sparse voltage and sparse current phasor measurements. The proposed algorithm addresses the performance limitation of fault location algorithms based on only synchronized sparse voltage measurements (SSVM) and on only synchronized sparse current measurements (SSCM). In the proposed method, bus voltage phasor of faulty line or close to the faulty line and branch current phasor of the adjacent line is utilized. The paper contributes to improve the accuracy of fault location and deter the effect of CT saturation by using hybrid voltage and current measurements. The proposed algorithm has been tested on four bus two area power system and IEEE 14 bus system with the typical features of an actual distribution system. The robustness of algorithm has been tested by variation in fault location, fault resistance, load switching. The simulation results demonstrate the accuracy of the proposed algorithm and ensure a reliable fault detection and location method.

eess.SP