Geometry-Driven Passive Fluid Transport in Paper-Based Microdevices

Channel geometry strongly influences capillary-driven fluid transport in paper-based devices, yet systematic comparative studies correlating geometric design with flow behaviour and analyte confinement remain limited. The present study investigates five distinct channel geometries namely converging-diverging, diverging-converging, wide-to-narrow, circular, and rectangular that was fabricated on cellulose filter paper with a standardized area of 32.5 mm\textsuperscript{2} and analyzed using geometry-adapted extensions of the Lucas--Washburn equation. Pyrene and benz[α]anthracene were employed as fluorescent model analytes to enable UV-based quantification of analyte confinement within each geometry. Flow transport times ranged from 23.1 s (circular, fastest) to 65.0 s (diverging-converging, slowest), with corresponding mean velocities of 0.571 and 0.284 mm/s for pyrene respectively, demonstrating that channel geometry strongly influences capillary transport in paper-based devices. Diverging-converging and wide-to-narrow designs produced the greatest analyte confinement by imposing flow retardation and sustained channel acceleration respectively, while circular and rectangular designs yielded relatively uniform velocity distributions and weaker confinement. Cyclodextrin-functionalized chitosan coatings served as a surface chemistry tool to anchor analyte retention at designated preconcentration zones, enabling geometric effects to be isolated and quantified. Computational fluid dynamics simulations, calibrated against experimental flow data and validated through a mesh independence study, reproduced the experimentally observed velocity magnitude distributions across all five geometries, showing semi-quantitative agreement with geometry-adapted Lucas--Washburn predictions.

physics.flu-dyn↗

Single-step laser patterning and thinning of biocompatible MEMS flow sensor

Micro-electro mechanical systems (MEMS) thermal flow sensors are increasingly used for compact, low-power flow monitoring in biomedical applications. However, silicon-based method for sensor fabrication is limited by high cost, rigidity, and multi-step cleanroom processes. This study presents a single-step fiber laser micromachining method for fabricating biocompatible, free-standing MEMS thermal flow sensors from ultrathin titanium foil. The process combines patterning and localized thinning in single-step process, with titanium serving as resistive sensing element. A dual-matrix optimization approach consisting of a Threshold Mapping Matrix (TMM) and Energy Density Matrix (EDM) was used to determine optimized parameters without repeated trial-and-error. For localized thinning, sequential R-T scans with cooling intervals reduced redeposition from the Gaussian beam profile and produced uniform thickness reduction from 50 μm to 20--30 μm. The fabricated sensors were evaluated through thermal coefficient resistance (TCR) measurement, Infrared (IR) thermography, and airflow tests under steady and cyclic conditions controlled by artificial ventilation system. The fabricated devices showed a stable TCR of 3278 ppm °C$^{-1}$, a linear relationship calibration curve between velocity and resistance with $R^2$=0.986 and a 54% improvement in thermal response was achieved with the free-standing structure design compared to substrate-fixed designs. This fabrication approach removes the need for photolithography, wet/dry etching, and wafer bonding, enabling faster and lower-cost production of flexible, biocompatible flow sensors. The method can be applied to other MEMS devices that require compact size, flexibility, localized thinning and free-standing structures.

physics.ins-det↗

Laser fabrication of Ti stent and facile MEMS flow sensor integration for implantable respiration monitoring

Animal experiments play a vital role in drug discovery and development by providing essential data on a drug's efficacy, safety, and physiological effects before advancing to human clinical trials. In this study, we propose a stent-based flow sensor designed to measure airflow in the airways of laboratory animals. The stent was fabricated from biocompatible Ti using a combination of fiber laser digital processing and an origami-inspired folding technique. The sensing structure was developed through standard micro-electromechanical systems (MEMS) microfabrication technology. To integrate the sensing structure with the metallic stent, a facile insertion process was employed, where the sensor film was positioned at the stent's center using its natural buckling mechanism. Once fabricated, the stent implant was expanded and installed within an airway-mimicking tube to validate its functionality. A proof-of-concept trial using an artificial ventilator successfully demonstrated real-time respiration monitoring, confirming the feasibility of the proposed system for airflow measurement in preclinical studies. This stent-based sensor offers a promising approach for enhancing respiratory assessments in laboratory animals, potentially improving the accuracy of drug evaluations and respiratory disease research.