Human Cardiac Measurements with Diamond Magnetometers

We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).

physics.med-ph

Zero- to low-field J-spectroscopy with a diamond magnetometer

We report measurements of zero- to ultra-low-field nuclear magnetic resonance (ZULF NMR) signals at frequencies of a few hertz with a diamond-based magnetic sensor. The sensing diamond is a truncated pyramid with 0.18 mm height and a 0.5 mm x 0.5mm base. The minimum stand-off distance is < 1 mm, and the sensor sensitivity is 13 pT/(Hz)^(1/2) at frequencies f above 5 Hz with 1/f-like behavior at lower frequencies. NMR signals were generated via signal amplification by reversible exchange (SABRE) parahydrogen-based hyperpolarization resulting in zero-field signals at 1.7 Hz and 3.4 Hz corresponding to the expected hetero-nuclear J-coupling pattern of acetonitrile. This work demonstrates a magnet-free platform for detecting chemically specific NMR signals at ultra-low frequencies paving the way for portable noninvasive diagnostics in microscopic sample volumes for biomedicine, industrial sensing through metal enclosures, and field-deployable quantum analytical devices.

physics.app-ph

Towards high-sensitivity magnetometry with nitrogen vacancy centers in diamond using the singlet infrared absorption

The negatively-charged nitrogen vacancy (NV$^{-}$) center in diamond is widely used for quantum sensing since the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields make it an excellent probe for changes in these perturbations. The spin state can be measured through optically detected magnetic resonance (ODMR), which is most commonly achieved by detecting the photoluminescence (PL) after exciting the spin-triplet transition. Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead. These methods however require cryogenic temperatures or external cavities to enhance the absorption signal. Here, we report on our optimization efforts of the magnetometer sensitivity at room temperature and without cavities. We reach sensitivities of 18 pT$/\sqrt{\mathrm{Hz}}$, surpassing previously reported values. We also report on a defect that is native to CVD-grown diamond and thus absent in HPHT diamond, the excitation of which impacts the measured singlet absorption signal.

quant-ph

Microwave-free wide-field magnetometry using nitrogen-vacancy centers

A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of NV centers near the ground state level anticrossing (GSLAC). An applied test field from a wire was mapped over an imaging area of $\approx 500 \times 470\,μ\text{m}^2$. Analysis of the GSLAC lineshape allows to extract vector information of the applied field. The device allows micrometer-scale magnetic imaging at a spatial resolution dominated by the thickness of the NV layer (here $50\,μ\text{m}$). For a pixel size of $4\,μ\text{m} \times 3.8\,μ\text{m}$ the estimated sensitivity is $4.8\,μ\text{T}/\sqrt{\text{Hz}}$. Two modalities for visualizing the magnetic fields, static and temporal, are presented along with a discussion of technical limitations and future extensions of the method.

physics.app-ph

Near zero-field microwave-free magnetometry with ensembles of nitrogen-vacancy centers in diamond

We study cross-relaxation features near zero magnetic field with ensembles of nitrogen-vacancy (NV) centers in diamond and examine their properties in samples with a range (0.9 ppm - 16.0 ppm) of NV concentrations. The observed NV-NV cross-relaxation features between differently oriented NV centers in high (greater than 0.9 ppm)-NV-density samples hold promise for a variety of magnetometry applications where microwave fields (or any bias field) disturb the system under study. We theoretically determine the values of the bias magnetic fields corresponding to cross-relaxations between different axes and experimentally validate them. The behavior of zero-field cross-relaxation features as a function of temperature is also investigated.

cond-mat.mes-hall

Diamond-optic enhanced photon collection efficiency for sensing with nitrogen-vacancy centers

We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical read-out based measurements of for instance magnetic and electric fields, pressure, temperature and rotations.

quant-ph

Fiberized diamond-based vector magnetometers

We present two fiberized vector magnetic-field sensors, based on nitrogen-vacancy (NV) centers in diamond. The sensors feature sub-nT/$\sqrt{\textrm{Hz}}$ magnetic sensitivity. We use commercially available components to construct sensors with a small sensor size, high photon collection, and minimal sensor-sample distance. Both sensors are located at the end of optical fibres with the sensor-head freely accessible and robust under movement. These features make them ideal for mapping magnetic fields with high sensitivity and spatial resolution ($\leq$\,mm). As a demonstration we use one of the sensors to map the vector magnetic field inside the bore of a $\geq$ 100\,mT Halbach array. The vector field sensing protocol translates microwave spectroscopy data addressing all diamonds axes and including double quantum transitions to a 3D magnetic field vector.

quant-ph