Murali K. Ghatkesar

Publications and source records attributed to Murali K. Ghatkesar.

4 recordsLinked to original sources

Capacitive Pixelated CMOS Electronic Nose

Although some of the human senses can nowadays be replaced by low-cost electronic sensors such as microphones and image sensors, a compact low-cost electronic nose (E-nose) remains elusive. In this work, an E-nose is presented that can capacitively detect volatile organic compounds (VOCs). The E-nose consists of an array of 1024 capacitive microelectrodes on a complementary metal-oxide-semiconductor (CMOS) chip, functionalized by inkjet printing. The pixels are coated with a UV-curable ink and metal-organic frameworks (MOFs: ZIF-8, MIL-101(Cr), MIL-140A) to create chemically diverse microdomains that generate gas-specific response patterns through adsorption-driven dielectric loading. ZIF-8 exhibits the highest response to 2-butanone, whereas the UV-curable layer responds most strongly to toluene; both show low cross-sensitivity to water vapor, enabling operation under humid conditions. After calibration in pure gases, reproducible responses to controlled binary mixtures of toluene and 2-butanone are observed. The device operates at low power, combines a large 1024-pixel array with CMOS integration, and offers application-specific functionalization by inkjet printing, providing both low cost and versatility. By further extending the range of functionalization materials, the E-nose can be applied to analyze a wide variety of gases, with potential applications in safety monitoring, health, agriculture, and robotics.

physics.app-ph↗

Resolution Limits of Resonant Sensors with Duffing Non-Linearity

The resolution of resonant sensors is fundamentally limited by the presence of noise. Thermomechanical noise, intrinsic to the resonator, sets the ultimate sensor performance when all other noise sources have been eliminated. For linear resonators, the sensing resolution can always be further improved by increasing the driving power. However, this trend cannot continue indefinitely, since at sufficiently high driving powers non-linear effects emerge and influence the noise performance. As a consequence, the resonator's non-linear characteristics play an inextricable role in determining its ultimate resolution limits. Recently, several works have studied the characteristic performance of non-linear resonators as sensors, with the counter intuitive conclusion that increasing the quality factor of a resonator does not improve its sensing resolution at the thermomechanical limit. In this work we further analyze the ultimate resolution limits, and describe different regimes of performance at integration times below and above the resonator's decay time. We provide an analytical model to elucidate the effects of Duffing non-linearity on the resolution of closed-loop sensors, and validate it using numerical simulations. In contrast to previous works, our model and simulations show that under certain conditions the ultimate sensing resolution of a Duffing resonator can be improved by maximizing its quality factor. With measurements on a nanomechanical membrane resonator, we experimentally verify the model and demonstrate that frequency resolutions can be achieved that surpass the previously known limits.

physics.app-ph↗

Method to Determine the Closed-Loop Precision of Resonant Sensors from Open-Loop Measurements

Resonant sensors determine a sensed parameter by measuring the resonance frequency of a resonator. For fast continuous sensing, it is desirable to operate resonant sensors in a closed-loop configuration, where a feedback loop ensures that the resonator is always actuated near its resonance frequency, so that the precision is maximized even in the presence of drifts or fluctuations of the resonance frequency. However, in a closed-loop configuration, the precision is not only determined by the resonator itself, but also by the feedback loop, even if the feedback circuit is noiseless. Therefore, to characterize the intrinsic precision of resonant sensors, the open-loop configuration is often employed. To link these measurements to the actual closed-loop performance of the resonator, it is desirable to have a relation that determines the closed-loop precision of the resonator from open-loop characterisation data. In this work, we present a methodology to estimate the closed-loop resonant sensor precision by relying only on an open-loop characterization of the resonator. The procedure is beneficial for fast performance estimation and benchmarking of resonant sensors, because it does not require actual closed-loop sensor operation, thus being independent on the particular implementation of the feedback loop. We validate the methodology experimentally by determining the closed-loop precision of a mechanical resonator from an open-loop measurement and comparing this to an actual closed-loop measurement.

physics.app-ph↗

Mass measurement of graphene using quartz crystal microbalances

Current wafer-scale fabrication methods for graphene-based electronics and sensors involve the transfer of single-layer graphene by a support polymer. This often leaves some polymer residue on the graphene, which can strongly impact its electronic, thermal, and mechanical resonance properties. To assess the cleanliness of graphene fabrication methods, it is thus of considerable interest to quantify the amount of contamination on top of the graphene. Here, we present a methodology for direct measurement of the mass of the graphene sheet using quartz crystal microbalances (QCM). By monitoring the QCM resonance frequency during removal of graphene in an oxygen plasma, the total mass of the graphene and contamination is determined with sub-graphene-monolayer accuracy. Since the etch-rate of the contamination is higher than that of graphene, quantitative measurements of the mass of contaminants below, on top, and between graphene layers are obtained. We find that polymer-based dry transfer methods can increase the mass of a graphene sheet by a factor of 10. The presented mass measurement method is conceptually straightforward to interpret and can be used for standardized testing of graphene transfer procedures in order to improve the quality of graphene devices in future applications.

cond-mat.mes-hall↗