SearcharxivSearch

arXiv subjects

MyeongJae Lee

Publications and source records attributed to MyeongJae Lee.

15 recordsLinked to original sources

Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz

We report a follow-up axion haloscope search near 1.036 GHz that completes and extends our previous work [Phys. Rev. X 14, 031023 (2024)], in which a portion of the HEMT-based data could not be analyzed due to unrecorded experimental information. While recovering this dataset, we identified an excess near 1.036 GHz that satisfied our candidate-selection criteria, motivating dedicated validation studies, including independent cross-checks and re-examination with the original apparatus. The excess did not persist under these investigations and was not confirmed as an axion dark-matter signal. We subsequently extended the search over a 20-MHz band surrounding the candidate using a quantum-noise-limited amplifier, achieving sensitivity close to the Dine-Fischler-Srednicki-Zhitnitsky benchmark. In the absence of a confirmed signal, we set improved 90% confidence-level upper limits on the axion-photon coupling over the frequency range 1.026-1.045 GHz. This work highlights the importance of robust candidate-validation strategies as haloscope searches approach discovery-level sensitivity.

hep-ex

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

hep-ex

Track reconstruction for the COMET Phase-II experiment with ACTS

An implementation of A Common Tracking Software (ACTS) toolkit for signal electron reconstruction for the COMET muon to electron conversion experiment is discussed. The COMET experiment in J-PARC, Japan, will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus, a lepton flavour violating process, aiming target sensitivity of $10^{-17}$. To achieve its scientific goals, the experiment requires a reconstructed momentum resolution of lower than 150 keV/c. For the first time by applying ACTS to signal events in the 100 MeV energy range with multiple-turn trajectories in the presence of background events, it is found that the reconstruction efficiency is around 14\% with no fake reconstructed events. The implementation details, performance, and issues of ACTS in the context of COMET are presented.

hep-ex

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.

hep-ex

Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex

Muon to positron conversion

Lepton flavor violation (LFV) has been discovered in the neutrino sector by neutrino oscillation experiments. The minimally extended Standard Model (SM) to include neutrino masses allows LFV in the charged sector (CLFV) at the loop-level, but at rates that are too small to be experimentally observed. Lepton number violation (LNV) is explicitly forbidden even in the minimally extended SM, where the observation of a LNV process would be unambiguous evidence of physics beyond the SM. The search for the LNV and CLFV process $μ^- + N(A,Z) \to e^+ + N'(A,Z-2)$ (referred to as $μ^- \to e^+$ conversion) is a complementary LNV channel to neutrinoless double beta decay searches, sensitive to potential flavor effects in the neutrino mass generation mechanism. A theoretical motivation for $μ^- \to e^+$ conversion is presented along with a review of the status of past $μ^- \to e^+$ conversion experiments and future prospects. Special attention is taken to understanding an uncertain and potentially dominant background for these searches, radiative muon capture, and its potential impacts on current and future $μ^- \to e^+$ searches.

hep-ex

Experimental Searches for Muon to Electron Conversion in a Nucleus: COMET, DeeMe, and Mu2e. A Contributed paper for Snowmass 21

Searches for charged lepton flavor violation (CLFV) offer deep probes for a range of new physics scenarios, such as super-symmetric models, theories involving scalar leptoquarks or additional Higgs doublets, and models explaining the neutrino mass hierarchy and the matter-antimatter asymmetry of the universe via leptogenesis. The coherent, neutrinoless conversion of a muon to an electron in the field of a nucleus, $μ^{-}+N\rightarrow e^{-} +N$, is one example of a muonic CLFV process which has sensitivity to this new physics. This paper details three experiments: COMET, DeeMe and Mu2e which will search for $μ^{-}+N\rightarrow e^{-} +N$ in the coming decade. These experiments offer sensitivity up to an effective new physics mass scale of $\mathcal{O}(10^{4}$ TeV/c$^{2}$), going far beyond what can be achieved in direct, collider-based, searches. The theoretical motivation, designs and anticipated timelines for these three experiments are presented. These experiments are a crucial part of a global search for CLFV. Continued support for all planned experimental searches for muonic CLFV is strongly encouraged.

hep-ex

Development of an FPGA-based realtime DAQ system for axion haloscope experiments

A real-time Data Acquisition (DAQ) system for the CULTASK axion haloscope experiment was constructed and tested. The CULTASK is an experiment to search for cosmic axions using resonant cavities, to detect photons from axion conversion through the inverse Primakoff effect in a few GHz frequency range in a very high magnetic field and at an ultra low temperature. The constructed DAQ system utilizes a Field Programmable Gate Array (FPGA) for data processing and Fast Fourier Transformation. This design along with a custom Ethernet packet designed for real-time data transfer enables 100% DAQ efficiency, which is the key feature compared with a commercial spectrum analyzer. This DAQ system is optimally designed for RF signal detection in the axion experiment, with 100 Hz frequency resolution and 500 kHz analysis window. The noise level of the DAQ system averaged over 100,000 measurements is around -111.7 dBm. From a pseudo-data analysis, an improvement of the signal-to-noise ratio due to repeating and averaging the measurements using this real-time DAQ system was confirmed.

physics.ins-det

An FPGA-based Trigger System with Online Track Recognition in COMET Phase-I

An FPGA-based online trigger system has been developed for the COMET Phase-I experiment. This experiment searches for muon-to-electron conversion, which has never been observed yet. A drift chamber and trigger counters detect a mono-energetic electron from the conversion process in a 1-T solenoidal magnetic field. A highly intense muon source is applied to reach unprecedented experimental sensitivity. It also generates undesirable background particles, and a trigger rate due to these particles is expected to be much higher than an acceptable trigger rate in the data acquisition system. By using hit information from the drift chamber too, the online trigger system efficiently suppresses a background trigger rate while keeping signal-event acceptance large. A characteristic of this system is the utilization of the machine learning technique in the form of look-up tables on hardware. An initial simulation study indicates that the signal-event acceptance of the online trigger is 96% while the background trigger rate is reduced from over $90\,\mathrm{kHz}$ to $13\,\mathrm{kHz}$. For this scenario, we have produced trigger-related electronics that construct a distributed trigger architecture. The total latency of the trigger system was estimated to be $3.2\,\mathrm{μs}$, and the first operation test was carried out by using a part of the drift-chamber readout region.

physics.ins-det

First Results from Axion Haloscope at CAPP around 10.7 $μ$eV

The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

hep-ex

GPU-Accelerated Event Reconstruction for the COMET Phase-I Experiment

This paper discusses a parallelized event reconstruction of the COMET Phase-I experiment. The experiment aims to discover charged lepton flavor violation by observing 104.97 MeV electrons from neutrinoless muon-to-electron conversion in muonic atoms. The event reconstruction of electrons with multiple helix turns is a challenging problem because hit-to-turn classification requires a high computation cost. The introduced algorithm finds an optimal seed of position and momentum for each turn partition by investigating the residual sum of squares based on distance-of-closest-approach (DCA) between hits and a track extrapolated from the seed. Hits with DCA less than a cutoff value are classified for the turn represented by the seed. The classification performance was optimized by tuning the cutoff value and refining the set of classified hits. The workload was parallelized over the seeds and the hits by defining two GPU kernels, which record track parameters extrapolated from the seeds and finds the DCAs of hits, respectively. A reasonable efficiency and momentum resolution was obtained for a wide momentum region which covers both signal and background electrons. The event reconstruction results from the CPU and GPU were identical to each other. The benchmarked GPUs had an order of magnitude of speedup over a CPU with 16 cores while the exact speed gains varied depending on their architectures.

physics.ins-det

Radiation hardness study for the COMET Phase-I electronics

Radiation damage on front-end readout and trigger electronics is an important issue in the COMET Phase-I experiment at J-PARC, which plans to search for the neutrinoless transition of a muon to an electron. To produce an intense muon beam, a high-power proton beam impinges on a graphite target, resulting in a high-radiation environment. We require radiation tolerance to a total dose of $1.0\,\mathrm{kGy}$ and $1\,\mathrm{MeV}$ equivalent neutron fluence of $1.0\times10^{12}\,\mathrm{n_{eq}\,cm^{-2}}$ including a safety factor of 5 over the duration of the physics measurement. The use of commercially-available electronics components which have high radiation tolerance, if such components can be secured, is desirable in such an environment. The radiation hardness of commercial electronic components has been evaluated in gamma-ray and neutron irradiation tests. As results of these tests, voltage regulators, ADCs, DACs, and several other components were found to have enough tolerance to both gamma-ray and neutron irradiation at the level we require.

physics.ins-det

Axion Dark Matter Research with IBS/CAPP

The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.

physics.ins-det

Future Experimental Improvement for the Search of LNV Process in $eμ$ Sector

Exploring the leptonic sector in frontier experiments is more of importance nowadays, since the conservation of lepton flavor and total lepton number are not guaranteed anymore in the Standard Model after the discovery of neutrino oscillations. $μ^- + N(A,Z) \rightarrow e^+ + N(A,Z-2)$ conversion in a muonic atom is one of the most promising channels to investigate the lepton number violation process, and the measurement of this process is planned in future $μ^--e^-$ conversion experiments with a muonic atom in a muon-stopping target. This paper discusses how to maximize the experimental sensitivity of the $μ^--e^+$ conversion by introducing the new requirement of the mass relation of $M(A,Z-2)<M(A,Z-1)$, where $M(A,Z)$ is the mass of the muon-stopping target nucleus, to get rid of the background from radiative muon capture. The sensitivity of the $μ^--e^+$ conversion is anticipated to have four orders of magnitude of improvement in forthcoming experiments using a proper target nucleus, which satisfies the mass relation. The most promising isotopes found are $^{40}$Ca and $^{32}$S.

hep-ex

Design and Performance of a Custom ASIC Digitizer for Wire Chamber Readout in 65 nm CMOS Technology

We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital Converters (TDCs), one 8-bit Analog-to-Digital Converter (ADC), a front-end preamplifier and shaper, plus digital and analog buffers that support a variety of digitization chains. The prototype has a multiplexed digital backend that executes a state machine, distributes control and timing signals, and buffers data for serial output. Laboratory bench tests measure the absolute TDC resolution between 74 ps and 480 ps, growing with the absolute delay, and a relative time resolution of 19 ps. Resolution outliers due to cross-talk between clock signals and supply or reference voltages are seen. After calibration, the ADC displays good linearity and noise performance, with an effective number of bits of 6.9. Under normal operating conditions the circuit consumes 32 mW per channel. Potential design improvements to address the resolution drift and tails are discussed.

physics.ins-det