Searcharxiv⌕ Search

arXiv subjects

N. A. Kuchinskiy

Publications and source records attributed to N. A. Kuchinskiy.

5 recordsLinked to original sources

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex↗

2-D straw detectors with high rate capability

Precise measurement of straw axial coordinate (along the anode wire) with accuracy compatible with straw radial coordinate determination by drift time measurement and increase of straw detector rate capability by using straw cathode readout instead of anode readout are presented.

physics.ins-det↗

The use of segmented cathode of a drift tube for designing a track detector with a high rate capability

Detector rate capability is one of the main parameters for designing a new detector for high energy physics due to permanent rise of the beam luminosity of modern accelerators. One of the widely used detectors for particle track reconstruction is a straw detector based on drift tubes. The rate capability of such detectors is limited by the parameters of readout electronics. The traditional method of increasing detector rate capability is increasing their granularity (a number of readout channels) by reducing the straw diameter and/or by dividing the straw anode wire into two parts (for decreasing the rate per readout channel). A new method of designing straw detectors with a high rate capability is presented and tested. The method is based on dividing the straw cathode into parts and independent readout of each part.

physics.ins-det↗

Using the cathode surface of straw tube for measuring the track coordinates along the wire

The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate along the wire constitutes a problem. This paper proposes a method for measuring the hit coordinate along the wire with an accuracy better than 1 mm in a straw tube detector using the signals from the cathodes of the detector.

physics.ins-det↗

Detector with a profile-based cathode and a two-coordinate pad-strip readout system

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle with respect to the anode wire. Two coordinates from the cathodes and one from the anode wire allow identification of tracks in high multiplicity events with a single detector plane.

physics.ins-det↗