SearcharxivSearch

arXiv subjects

N. A. Kurinsky

Publications and source records attributed to N. A. Kurinsky.

At least 19 recordsLinked to original sources

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

physics.ins-det

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

hep-ex

A First Demonstration of the SQUAT Detector Architecture: Direct Measurement of Resonator-Free Charge-Sensitive Transmons

The Superconducting Quasiparticle-Amplifying Transmon (SQUAT) is a new sensor architecture for THz (meV) detection based on a weakly charge-sensitive transmon directly coupled to a transmission line. In such devices, energy depositions break Cooper pairs in the qubit capacitor islands, generating quasiparticles. Quasiparticles that tunnel across the Josephson junction change the transmon qubit parity, generating a measurable signal. In this paper, we present the design of first-generation SQUATs and demonstrate an architecture validation. We summarize initial characterization measurements made with prototype devices, comment on background sources that influence the observed parity-switching rate, and present experimental results showing simultaneous detection of charge and quasiparticle signals using aluminum-based SQUATs.

physics.ins-det

Low-Energy Calibration of SuperCDMS HVeV Cryogenic Silicon Calorimeters Using Compton Steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. We demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution (HVeV) detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

physics.ins-det

Broadband Optical Modulation and Control at Millikelvin Temperatures

A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact cryogenic optical beam steering system that can be used to generate O(μs) pulses of small numbers of photons over the energy range of 1.2 - 4.5eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including supercondcting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

physics.ins-det

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

physics.ins-det

SPLENDOR: a novel detector platform to search for light dark matter with narrow-gap semiconductors

We present the design and current status of SPLENDOR, a novel detector platform that combines narrow-gap semiconductor targets with low-noise charge readout to achieve sensitivity to dark matter energy deposits well below the eV scale. SPLENDOR is designed to be a modular and scalable system able to accommodate different target materials and signal readout technologies. SPLENDOR's present strategy entails: (i) the use of strongly correlated f-electron semiconductors with anisotropic electronic structures to enable not only sub-eV energy thresholds, but also directional sensitivity to the incoming dark matter flux, allowing for signal-background discrimination via daily modulation, and (ii) custom charge readout based on cryogenic high-electron-mobility transistor (cryoHEMT) amplifiers approaching single-electron resolution. We report on the selection and characterization of Eu$_5$In$_2$Sb$_6$ as the target material for SPLENDOR's first prototype detector, as well as the development and calibration of the prototype amplifier chain, achieving a measured charge resolution of 20$\pm$7 electrons in silicon test samples, consistent with predicted performance. This provides a demonstration of the detector architecture, which is now ready for deployment in a dark matter search campaign to deliver SPLENDOR's first science results. Finally, we present estimates of sensitivity reach in the parameter space of athermally produced relic dark matter under high- and low-background environments, and for various amplifier technology upgrades with increasing performance, including planned quantum sensing upgrades in order to achieve our ultimate goal of sub-electron resolution in optimized systems. SPLENDOR provides a novel approach to dark matter direct detection, combining quantum sensing with material's design to open new avenues of exploration in the sub-MeV mass range of dark matter parameter space.

physics.ins-det

First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.

hep-ex

Athermal phonon collection efficiency in diamond crystals for low mass dark matter detection

We explored the efficacy of lab-grown diamonds as potential target materials for the direct detection of sub-GeV dark matter~(DM) using metallic magnetic calorimeters~(MMCs). Diamond, with its excellent phononic properties and the low atomic mass of the constituent carbon, can play a crucial role in detecting low-mass dark matter particles. The relatively long electron-hole pair lifetime inside the crystal may provide discrimination power between the DM-induced nuclear recoil events and the background-induced electron recoil events. Utilizing the the fast response times of the MMCs and their unique geometric versatility, we deployed a novel methodology for quantifying phonon dynamics inside diamond crystals. We demonstrated that lab-grown diamond crystals fabricated via the chemical vapor deposition~(CVD) technique can satisfy the stringent quality requirements for sub-GeV dark matter searches. The high-quality polycrystalline CVD diamond showed a superior athermal phonon collection efficiency compared to that of the reference sapphire crystal, and achieved energy resolution 62.7~eV at the 8.05~keV copper fluorescence line. With this energy resolution, we explored the low-energy range below 100~eV and confirmed the existence of so-called low-energy excess~(LEE) reported by multiple cryogenic experiments.

physics.ins-det

Quasiparticle poisoning of superconducting qubits with active gamma irradiation

When a high-energy particle, such as a $γ$-ray or muon, impacts the substrate of a superconducting qubit chip, large numbers of electron-hole pairs and phonons are created. The ensuing dynamics of the electrons and holes changes the local offset-charge environment for qubits near the impact site. The phonons that are produced have energy above the superconducting gap in the films that compose the qubits, leading to quasiparticle excitations above the superconducting ground state when the phonons impinge on the qubit electrodes. An elevated density of quasiparticles degrades qubit coherence, leading to errors in qubit arrays. Because these pair-breaking phonons spread throughout much of the chip, the errors can be correlated across a large portion of the array, posing a significant challenge for quantum error correction. In order to study the dynamics of $γ$-ray impacts on superconducting qubit arrays, we use a $γ$-ray source outside the dilution refrigerator to controllably irradiate our devices. By using charge-sensitive transmon qubits, we can measure both the offset-charge shifts and quasiparticle poisoning due to the $γ$ irradiation at different doses. We study correlations between offset-charge shifts and quasiparticle poisoning for different qubits in the array and compare this with numerical modeling of charge and phonon dynamics following a $γ$-ray impact. We thus characterize the poisoning footprint of these impacts and quantify the performance of structures for mitigating phonon-mediated quasiparticle poisoning.

quant-ph

Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.

hep-ex

First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility

We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

quant-ph

Improved Modelling of Detector Response Effects in Phonon-based Crystal Detectors used for Dark Matter Searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

physics.ins-det

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

quant-ph

Two-Stage Cryogenic HEMT Based Amplifier For Low Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$(MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1-100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance ($\sim$1.6 pF) HEMT is used as a buffer stage at $T=10\,\mathrm{mK}$ to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance ($\sim$200 pF) HEMT amplifier stage at $T=4\,\mathrm{K}$. Importantly, the design of this amplifier makes it usable with any insulating material - allowing for rapid prototyping of a variety of novel detector materials. We present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

physics.ins-det

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

physics.ins-det

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

hep-ex

First measurement of the nuclear-recoil ionization yield in silicon at 100 eV

We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

physics.ins-det