SearcharxivSearch

arXiv subjects

N. A. Larsen

Publications and source records attributed to N. A. Larsen.

At least 19 recordsLinked to original sources

The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector

Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.

physics.ins-det

BICEP2 / Keck Array XI: Beam Characterization and Temperature-to-Polarization Leakage in the BK15 Dataset

Precision measurements of cosmic microwave background (CMB) polarization require extreme control of instrumental systematics. In a companion paper we have presented cosmological constraints from observations with the BICEP2 and Keck Array experiments up to and including the 2015 observing season (BK15), resulting in the deepest CMB polarization maps to date and a statistical sensitivity to the tensor-to-scalar ratio of $σ(r) = 0.020$. In this work we characterize the beams and constrain potential systematic contamination from main beam shape mismatch at the three BK15 frequencies (95, 150, and 220 GHz). Far-field maps of 7,360 distinct beam patterns taken from 2010-2015 are used to measure differential beam parameters and predict the contribution of temperature-to-polarization leakage to the BK15 B-mode maps. In the multifrequency, multicomponent likelihood analysis that uses BK15, Planck, and WMAP maps to separate sky components, we find that adding this predicted leakage to simulations induces a bias of $Δr = 0.0027 \pm 0.0019$. Future results using higher-quality beam maps and improved techniques to detect such leakage in CMB data will substantially reduce this uncertainty, enabling the levels of systematics control needed for BICEP Array and other experiments that plan to definitively probe large-field inflation.

astro-ph.IM

An Effective Field Theory Analysis of the First LUX Dark Matter Search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

astro-ph.CO

Extending light WIMP searches to single scintillation photons in LUX

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

astro-ph.CO

BICEP2 / Keck Array IX: New Bounds on Anisotropies of CMB Polarization Rotation and Implications for Axion-Like Particles and Primordial Magnetic Fields

We present the strongest constraints to date on anisotropies of cosmic microwave background (CMB) polarization rotation derived from 150 GHz data taken by the BICEP2/Keck Array CMB experiments up to and including the 2014 observing season (BK14). The definition of the polarization angle in BK14 maps has gone through self-calibration in which the overall angle is adjusted to minimize the observed TB and EB power spectra. After this procedure, the QU maps lose sensitivity to a uniform polarization rotation but are still sensitive to anisotropies of polarization rotation. This analysis places constraints on the anisotropies of polarization rotation, which could be generated by CMB photons interacting with axionlike pseudoscalar fields or Faraday rotation induced by primordial magnetic fields. The sensitivity of BK14 maps ($\sim 3μ$K-arcmin) makes it possible to reconstruct anisotropies of the polarization rotation angle and measure their angular power spectrum much more precisely than previous attempts. Our data are found to be consistent with no polarization rotation anisotropies, improving the upper bound on the amplitude of the rotation angle spectrum by roughly an order of magnitude compared to the previous best constraints. Our results lead to an order of magnitude better constraint on the coupling constant of the Chern-Simons electromagnetic term $g_{aγ}\leq 7.2\times 10^{-2}/H_I$ (95% confidence) than the constraint derived from the B-mode spectrum, where $H_I$ is the inflationary Hubble scale. This constraint leads to a limit on the decay constant of $10^{-6}\lesssim f_a/M_{\rm pl}$ at mass range of $10^{-33}< m_a< 10^{-28}$ eV for $r=0.01$, assuming $g_{aγ}\simα/(2πf_a)$ with $α$ denoting the fine structure constant. The upper bound on the amplitude of the primordial magnetic fields is 30nG (95% confidence) from the polarization rotation anisotropies.

astro-ph.CO

Measurements of Degree-Scale B-mode Polarization with the BICEP/Keck Experiments at South Pole

The BICEP and Keck Array experiments are a suite of small-aperture refracting telescopes observing the microwave sky from the South Pole. They target the degree-scale B-mode polarization signal imprinted in the Cosmic Microwave Background (CMB) by primordial gravitational waves. Such a measurement would shed light on the physics of the very early universe. While BICEP2 observed for the first time a B-mode signal at 150 GHz, higher frequencies from the Planck satellite showed that it could be entirely due to the polarized emission from Galactic dust, though uncertainty remained high. Keck Array has been observing the same region of the sky for several years, with an increased detector count, producing the deepest polarized CMB maps to date. New detectors at 95 GHz were installed in 2014, and at 220 GHz in 2015. These observations enable a better constraint of galactic foreground emissions, as presented here. In 2015, BICEP2 was replaced by BICEP3, a 10 times higher throughput telescope observing at 95 GHz, while Keck Array is now focusing on higher frequencies. In the near future, BICEP Array will replace Keck Array, and will allow unprecedented sensitivity to the gravitational wave signal. High resolution observations from the South Pole Telescope (SPT) will also be used to remove the lensing contribution to B-modes.

astro-ph.CO

BICEP2 / Keck Array x: Constraints on Primordial Gravitational Waves using Planck, WMAP, and New BICEP2/Keck Observations through the 2015 Season

We present results from an analysis of all data taken by the BICEP2/Keck CMB polarization experiments up to and including the 2015 observing season. This includes the first Keck Array observations at 220 GHz and additional observations at 95 & 150 GHz. The $Q/U$ maps reach depths of 5.2, 2.9 and 26 $μ$K$_{cmb}$ arcmin at 95, 150 and 220 GHz respectively over an effective area of $\approx 400$ square degrees. The 220 GHz maps achieve a signal-to-noise on polarized dust emission approximately equal to that of Planck at 353 GHz. We take auto- and cross-spectra between these maps and publicly available WMAP and Planck maps at frequencies from 23 to 353 GHz. We evaluate the joint likelihood of the spectra versus a multicomponent model of lensed-$Λ$CDM+$r$+dust+synchrotron+noise. The foreground model has seven parameters, and we impose priors on some of these using external information from Planck and WMAP derived from larger regions of sky. The model is shown to be an adequate description of the data at the current noise levels. The likelihood analysis yields the constraint $r_{0.05}<0.07$ at 95% confidence, which tightens to $r_{0.05}<0.06$ in conjunction with Planck temperature measurements and other data. The lensing signal is detected at $8.8 σ$ significance. Running maximum likelihood search on simulations we obtain unbiased results and find that $σ(r)=0.020$. These are the strongest constraints to date on primordial gravitational waves.

astro-ph.CO

High-Precision Scanning Water Vapor Radiometers for Cosmic Microwave Background Site Characterization and Comparison

The compelling science case for the observation of B-mode polarization in the cosmic microwave background (CMB) is driving the CMB community to expand the observed sky fraction, either by extending survey sizes or by deploying receivers to potential new northern sites. For ground-based CMB instruments, poorly-mixed atmospheric water vapor constitutes the primary source of short-term sky noise. This results in short-timescale brightness fluctuations, which must be rejected by some form of modulation. To maximize the sensitivity of ground-based CMB observations, it is useful to understand the effects of atmospheric water vapor over timescales and angular scales relevant for CMB polarization measurements. To this end, we have undertaken a campaign to perform a coordinated characterization of current and potential future observing sites using scanning 183 GHz water vapor radiometers (WVRs). So far, we have deployed two identical WVR units; one at the South Pole, Antarctica, and the other at Summit Station, Greenland. The former site has a long heritage of ground-based CMB observations and is the current location of the Bicep/Keck Array telescopes as well as the South Pole Telescope. The latter site, though less well characterized, is under consideration as a northern-hemisphere location for future CMB receivers. Data collection from this campaign began in January 2016 at South Pole and July 2016 at Summit Station. Data analysis is ongoing to reduce the data to a single spatial and temporal statistic that can be used for one-to-one site comparison.

astro-ph.IM

BICEP Array cryostat and mount design

Bicep Array is a cosmic microwave background (CMB) polarization experiment that will begin observing at the South Pole in early 2019. This experiment replaces the five Bicep2 style receivers that compose the Keck Array with four larger Bicep3 style receivers observing at six frequencies from 30 to 270GHz. The 95GHz and 150GHz receivers will continue to push the already deep Bicep/Keck CMB maps while the 30/40GHz and 220/270GHz receivers will constrain the synchrotron and galactic dust foregrounds respectively. Here we report on the design and performance of the Bicep Array instruments focusing on the mount and cryostat systems.

astro-ph.IM

Ultra-Thin Large-Aperture Vacuum Windows for Millimeter Wavelengths Receivers

Targeting faint polarization patterns arising from Primordial Gravitational Waves in the Cosmic Microwave Background requires excellent observational sensitivity. Optical elements in small aperture experiments such as Bicep3 and Keck Array are designed to optimize throughput and minimize losses from transmission, reflection and scattering at millimeter wavelengths. As aperture size increases, cryostat vacuum windows must withstand larger forces from atmospheric pressure and the solution has often led to a thicker window at the expense of larger transmission loss. We have identified a new candidate material for the fabrication of vacuum windows: with a tensile strength two orders of magnitude larger than previously used materials, woven high-modulus polyethylene could allow for dramatically thinner windows, and therefore significantly reduced losses and higher sensitivity. In these proceedings we investigate the suitability of high-modulus polyethylene windows for ground-based CMB experiments, such as current and future receivers in the Bicep/Keck Array program. This includes characterizing their optical transmission as well as their mechanical behavior under atmospheric pressure. We find that such ultra-thin materials are promising candidates to improve the performance of large-aperture instruments at millimeter wavelengths, and outline a plan for further tests ahead of a possible upcoming field deployment of such a science-grade window.

astro-ph.IM

BICEP Array: a multi-frequency degree-scale CMB polarimeter

BICEP Array is the newest multi-frequency instrument in the BICEP/Keck Array program. It is comprised of four 550 mm aperture refractive telescopes observing the polarization of the cosmic microwave background (CMB) at 30/40, 95, 150 and 220/270 GHz with over 30,000 detectors. We present an overview of the receiver, detailing the optics, thermal, mechanical, and magnetic shielding design. BICEP Array follows BICEP3's modular focal plane concept, and upgrades to 6" wafer to reduce fabrication with higher detector count per module. The first receiver at 30/40 GHz is expected to start observing at the South Pole during the 2019-20 season. By the end of the planned BICEP Array program, we project $σ(r) \sim 0.003$, assuming current modeling of polarized Galactic foreground and depending on the level of delensing that can be achieved with higher resolution maps from the South Pole Telescope.

astro-ph.IM

Design and performance of wide-band corrugated walls for the BICEP Array detector modules at 30/40 GHz

BICEP Array is a degree-scale Cosmic Microwave Background (CMB) experiment that will search for primordial B-mode polarization while constraining Galactic foregrounds. BICEP Array will be comprised of four receivers to cover a broad frequency range with channels at 30/40, 95, 150 and 220/270 GHz. The first low-frequency receiver will map synchrotron emission at 30 and 40 GHz and will deploy to the South Pole at the end of 2019. In this paper, we give an overview of the BICEP Array science and instrument, with a focus on the detector module. We designed corrugations in the metal frame of the module to suppress unwanted interactions with the antenna-coupled detectors that would otherwise deform the beams of edge pixels. This design reduces the residual beam systematics and temperature-to-polarization leakage due to beam steering and shape mismatch between polarized beam pairs. We report on the simulated performance of single- and wide-band corrugations designed to minimize these effects. Our optimized design alleviates beam differential ellipticity caused by the metal frame to about 7% over 57% bandwidth (25 to 45 GHz), which is close to the level due the bare antenna itself without a metal frame. Initial laboratory measurements are also presented.

astro-ph.IM

2017 upgrade and performance of BICEP3: a 95GHz refracting telescope for degree-scale CMB polarization

BICEP3 is a 520mm aperture on-axis refracting telescope observing the polarization of the cosmic microwave background (CMB) at 95GHz in search of the B-mode signal originating from inflationary gravitational waves. BICEP3's focal plane is populated with modularized tiles of antenna-coupled transition edge sensor (TES) bolometers. BICEP3 was deployed to the South Pole during 2014-15 austral summer and has been operational since. During the 2016-17 austral summer, we implemented changes to optical elements that lead to better noise performance. We discuss this upgrade and show the performance of BICEP3 at its full mapping speed from the 2017 and 2018 observing seasons. BICEP3 achieves an order-of-magnitude improvement in mapping speed compared to a Keck 95GHz receiver. We demonstrate $6.6μK\sqrt{s}$ noise performance of the BICEP3 receiver.

astro-ph.IM

Position Reconstruction in LUX

The $(x, y)$ position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including ${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H ($β^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an $(x, y)$ position uncertainty of $σ$= 0.82 cm for events of only 200 electroluminescence photons and $σ$ = 0.17 cm for 4,000 electroluminescence photons. Such signals are associated with electron recoils of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.

physics.ins-det

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the results are presented. Detector performance is characterized, including measured efficiencies, stability of response, position resolution, and discrimination between electron- and nuclear-recoil populations. Models are developed for the drift field, optical properties, background populations, the electron- and nuclear-recoil responses, and the absolute rate of low-energy background events. Innovations in the analysis include in situ measurement of the photomultipliers' response to xenon scintillation photons, verification of fiducial mass with a low-energy internal calibration source, and new empirical models for low-energy signal yield based on large-sample, in situ calibrations.

physics.ins-det

3D Modeling of Electric Fields in the LUX Detector

This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacting massive particle (WIMP) searches. After the first period completed, a time-varying non-uniform negative charge developed in the polytetrafluoroethylene (PTFE) panels that define the radial boundary of the detector's active volume. This caused electric field variations in the detector in time, depth and azimuth, generating an electrostatic radially-inward force on electrons on their way upward to the liquid surface. To map this behavior, 3D electric field maps of the detector's active volume were built on a monthly basis. This was done by fitting a model built in COMSOL Multiphysics to the uniformly distributed calibration data that were collected on a regular basis. The modeled average PTFE charge density increased over the course of the exposure from -3.6 to $-5.5~μ$C/m$^2$. From our studies, we deduce that the electric field magnitude varied while the mean value of the field of $\sim200$~V/cm remained constant throughout the exposure. As a result of this work the varying electric fields and their impact on event reconstruction and discrimination were successfully modeled.

physics.ins-det

Chromatographic separation of radioactive noble gases from xenon

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes $^{85}$Kr and $^{39}$Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

physics.ins-det

Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.

physics.ins-det