Searcharxiv⌕ Search

arXiv subjects

N. Anfimov

Publications and source records attributed to N. Anfimov.

59 records · Page 4Linked to original sources

Measurement of the neutrino mixing angle $θ_{23}$ in NOvA

This Letter reports new results on muon neutrino disappearance from NOvA, using a 14 kton detector equivalent exposure of $6.05\times10^{20}$ protons-on-target from the NuMI beam at the Fermi National Accelerator Laboratory. The measurement probes the muon-tau symmetry hypothesis that requires maximal mixing ($θ_{23} = π/4$). Assuming the normal mass hierarchy, we find $Δm^2 = (2.67 \pm 0.11)\times 10^{-3}$ eV$^2$ and $\sin^2 θ_{23}$ at the two statistically degenerate values $0.404^{+0.030}_{-0.022}$ and $0.624^{+0.022}_{-0.030}$, both at the 68% confidence level. Our data disfavor the maximal mixing scenario with 2.6 $σ$ significance.

hep-ex↗

First measurement of electron neutrino appearance in NOvA

We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.

hep-ex↗

First measurement of muon-neutrino disappearance in NOvA

This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.

hep-ex↗

JUNO Conceptual Design Report

The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.

physics.ins-det↗

Investigation of gamma ray detection performance of thin LFS scintillator with MAPD readout

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance investigated in the range of energy 59.6 - 662 keV at room temperature. The results of measurements are presented in this work.

physics.ins-det↗